background image

   

Industrial

 

Electronic Devices 

 

 

 ADFweb.com S.r.l. 

 

User Manual   

DMX / BACnet Master

 

 

Document code: MN67704_ENG     Revision 1.000   Page 1 of 28

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

User Manual 

Revision 1.000 
English 

 

DMX / BACnet Master - Converter 

 (Order Code:  HD67704-IP-B2) 

 

For Website information:  

www.adfweb.com?Product=HD67704

 

 

For Price information: 

www.adfweb.com?Price=HD67704-IP-B2

 

 
 

Benefits and Main Features: 

 

Very easy to configure 

 

Triple electrical isolation 

 

Temperature range: -40°C/85°C (-40°F/185°F) 

 

For others BACnet Master products see also the following link: 

 

Converter BACnet Master to 

www.adfweb.com?Product=HD67712

      

(Modbus Slave) 

www.adfweb.com?Product=HD67714

       

(Modbus TCP Slave) 

www.adfweb.com?Product=HD67716

      

(PROFIBUS Slave) 

www.adfweb.com?Product=HD67717

      

(CAN)

 

www.adfweb.com?Product=HD67718

      

(CANopen) 

www.adfweb.com?Product=HD67719

       

(PROFINET) 

www.adfweb.com?Product=HD67721

      

(DeviceNet Slave) 

www.adfweb.com?Product=HD67722

      

(EtherNet/IP) 

www.adfweb.com?Product=HD67723

      

(NMEA 2000)

 

www.adfweb.com?Product=HD67725

      

(J1939) 

www.adfweb.com?Product=HD67726

      

(SNMP  Agent) 

www.adfweb.com?Product=HD67801

      

(KNX) 

www.adfweb.com?Product=HD67832

       

(DALI) 

 

 

Do you have an your customer protocol? 

www.adfweb.com?Product=HD67003

 

 

Do you need to choose a device? do you want help? 

www.adfweb.com?Cmd=helpme

 

 

 

User Manual   

 

Содержание HD67704-IP-B2

Страница 1: ...nverter BACnet Master to www adfweb com Product HD67712 Modbus Slave www adfweb com Product HD67714 Modbus TCP Slave www adfweb com Product HD67716 PROFIBUS Slave www adfweb com Product HD67717 CAN ww...

Страница 2: ...SUPPORT 28 RETURN POLICY 28 UPDATED DOCUMENTATION Dear customer we thank you for your attention and we remind you that you need to check that the following document is Updated Related to the product y...

Страница 3: ...ce can be used only by qualified personnel strictly in accordance with the specifications Qualified personnel are persons who are familiar with the installation assembly commissioning and operation of...

Страница 4: ...Industrial Electronic Devices ADFweb com S r l User Manual DMX BACnet Master Document code MN67704_ENG Revision 1 000 Page 4 of 28 EXAMPLE OF CONNECTION...

Страница 5: ...Industrial Electronic Devices ADFweb com S r l User Manual DMX BACnet Master Document code MN67704_ENG Revision 1 000 Page 5 of 28 CONNECTION SCHEME Figure 1 Connection scheme for HD67704 IP B2...

Страница 6: ...lation between Serial Power Supply Serial Ethernet Ethernet Power Supply Two directional information between DMX bus and BACnet bus Mountable on 35mm Rail DIN Wide power supply input range 8 24V AC or...

Страница 7: ...ENG Revision 1 000 Page 7 of 28 POWER SUPPLY The devices can be powered at 8 24V AC and 12 35V DC For more details see the two tables below VAC VDC Vmin Vmax Vmin Vmax 8V 24V 12V 35V Consumption at 24...

Страница 8: ...he position of the Dip1 of Dip Switch A The first with Dip1 of Dip Switch A at OFF position is used for the normal working of the device The second with Dip1 of Dip Switch A at ON position is used for...

Страница 9: ...Hz ON Device powered OFF Device not powered 2 BACnet communication yellow Blinks when a BACnet response is received Blinks quickly Boot state Blinks very slowly 0 5Hz update in progress 3 DMX communic...

Страница 10: ...1 like in figure The maximum length of the cable should be 1200m 4000 feet Here some codes of cables Belden p n 8132 2x 28AWG stranded twisted pairs conductor foil shield braid shield Belden p n 8284...

Страница 11: ...the device The Ethernet connection must be made using Connector2 of HD67704 IP B2 with at least a Category 5E cable The maximum length of the cable should not exceed 100m The cable has to conform to...

Страница 12: ...s with Windows called SW67704 It is downloadable from the site www adfweb com and its operation is described in this document this manual is referenced to the last version of the software present on o...

Страница 13: ...iguration A device s configuration can also be imported or exported To clone the configurations of a Programmable DMX BACnet Master Converter in order to configure another device in the same manner it...

Страница 14: ...language of the software and check the updatings for the compositor In the section Language it is possible to change the language of the software In the section Connection Options it is possible to c...

Страница 15: ...DMX BACnet Master Document code MN67704_ENG Revision 1 000 Page 15 of 28 In the section Software Settings it is possible to enable disable some keyboard s commands for an easier navigation inside the...

Страница 16: ...RESS the IP address to assign to the converter is defined In the field SUBNET Mask the SubNet Mask of the converter is defined In the field GATEWAY the default gateway of the network is defined This f...

Страница 17: ...Max Masters specifies the highest allowable address for master nodes The value shall be less than or equal to 127 The field Max Info Frames specifies the maximum number of information frames the node...

Страница 18: ...verter writes into the BACnet slaves only if DMX IN is set The means of the fields in the window BACnet in Read are the following In the field IP Address ID the IP address ID of the slave that contain...

Страница 19: ...t a number from 1 to 65535 if D Len is 6 it is possible to insert an IP and port in this format 192 168 2 188 47808 In the field Poll Time the frequency of the request is defined in ms In the field Ma...

Страница 20: ...equest is defined By checking the field En Dest it is possible to enable the Destination Network D Net Destination Length D Len and Destination Address D Adr These informations are used for make a req...

Страница 21: ...ll Time the frequency of the request is defined in ms In the field Max Error the number of consecutive errors that the Master waits before stopping the specific requests is defined In the field Channe...

Страница 22: ...0 Page 22 of 28 DMX DEFAULT VALUE By pressing the DMX Default Value button from the main window for SW67704 Fig 2 the DMX Default Value window appears Fig 5 In this section it is possible to define th...

Страница 23: ...tions you want to do Press the Execute update firmware button to start the upload When all the operations are OK turn off the Device Put Dip1 of Dip Switch A at OFF position Turn on the device At this...

Страница 24: ...restart the PC Check the LAN settings Check the Wi Fi settings If you are using the program inside a Virtual Machine try to use in the main Operating System If you are using Windows Seven Vista 8 or 1...

Страница 25: ...trial Electronic Devices ADFweb com S r l User Manual DMX BACnet Master Document code MN67704_ENG Revision 1 000 Page 25 of 28 MECHANICAL DIMENSIONS Figure 8 Mechanical dimensions scheme for HD67704 I...

Страница 26: ...e following HD67704 IP B 2 Connectors Type 2 Fixed 5mm Screw Terminal Enclosure Type B 4M 35mm DIN Rail mounting BACnet type IP BACnet IP MSTP BACnet MS TP Device Family HD67704 DMX BACnet Master Conv...

Страница 27: ...systems This symbol on the product or on its packaging indicates that this product may not be treated as household rubbish Instead it should be taken to an applicable collection point for the recycli...

Страница 28: ...the following Obtain a Product Return Number PRN from our internet support at www adfweb com Together with the request you need to provide detailed information about the problem Send the product to th...

Отзывы: