background image

   

Industrial

 

Electronic Devices 

 

 

 ADFweb.com S.r.l. 

 

User Manual   

S7comm / EtherNet/IP Slave

 

 

Document code: MN67627_ENG     Revision 1.000   Page 1 of 30

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

User Manual 

Revision 1.000 
English

 

 

S7comm / EtherNet/IP Slave - Converter

  

(Order Code:  HD67627-A1) 

 

For Website information:  

www.adfweb.com?Product=HD67627

    

 

For Price information: 

www.adfweb.com?Price=HD67627-A1

 

 

Benefits and Main Features: 

 

Very easy to configure 

 

Triple Electrical isolation 

 

Temperature range: -40°C/+85°C (-40°F/+185°F) 

 

For other S7comm products see also the following link: 

 

S7comm from/to …

 

www.adfweb.com?Product=HD67618

  

(

Modbus TCP Slave

www.adfweb.com?Product=HD67619

  

(

PROFIBUS Slave

www.adfweb.com?Product=HD67620

  

(

IEC61850 Server

www.adfweb.com?Product=HD67621

  

(

Serial

www.adfweb.com?Product=HD67622

   

(

Modbus Slave

www.adfweb.com?Product=HD67623

  

(

CAN

www.adfweb.com?Product=HD67624

  

(

CANopen

www.adfweb.com?Product=HD67625

  

(

DeviceNet Slave

www.adfweb.com?Product=HD67626

  

(

SNMP Agent

www.adfweb.com?Product=HD67628

  

(

KNX

www.adfweb.com?Product=HD67629

  

(

MQTT

www.adfweb.com?Product=HD67630

  

(

BACnet Slave

www.adfweb.com?Product=HD67631

  

(

Ethernet

www.adfweb.com?Product=HD67632

  

(

OPC UA Server

www.adfweb.com?Product=HD67633

  

(

PROFINET Slave

 
 

Do you have your customer protocol? Then go to: 

www.adfweb.com?Product=HD67003

 

 

Do you need to choose a device? Do you want help? 

www.adfweb.com?Cmd=helpme

 

 

User Manual   

 

Содержание HD67627-A1

Страница 1: ...us TCP Slave www adfweb com Product HD67619 PROFIBUS Slave www adfweb com Product HD67620 IEC61850 Server www adfweb com Product HD67621 Serial www adfweb com Product HD67622 Modbus Slave www adfweb c...

Страница 2: ...PORT 30 RETURN POLICY 30 UPDATED DOCUMENTATION Dear customer we thank you for your attention and we remind you that you need to check that the following document is Updated Related to the product you...

Страница 3: ...device can be used only by qualified personnel strictly in accordance with the specifications Qualified personnel are persons who are familiar with the installation assembly commissioning and operatio...

Страница 4: ...Industrial Electronic Devices ADFweb com S r l User Manual S7comm EtherNet IP Slave Document code MN67627_ENG Revision 1 000 Page 4 of 30 EXAMPLES OF CONNECTION...

Страница 5: ...Industrial Electronic Devices ADFweb com S r l User Manual S7comm EtherNet IP Slave Document code MN67627_ENG Revision 1 000 Page 5 of 30 CONNECTION SCHEME Figure 1 Connection scheme for HD67627 A1...

Страница 6: ...een Ethernet Power Supply Two directional information between EtherNet IP bus and S7comm bus Mountable on 35mm Rail DIN Wide power supply input range 8 24V AC or 12 35V DC Wide temperature range 40 C...

Страница 7: ...7627_ENG Revision 1 000 Page 7 of 30 POWER SUPPLY The devices can be powered at 8 24V AC and 12 35V DC For more details see the two tables below VAC VDC Vmin Vmax Vmin Vmax 8V 24V 12V 35V Consumption...

Страница 8: ...n the position of the Dip1 of Dip Switch A The first with Dip1 of Dip Switch A at OFF position is used for the normal working of the device The second with Dip1 of Dip Switch A at ON position is used...

Страница 9: ...owered OFF Device not powered 2 Device State green Blinks slowly 1Hz Blinks quickly Boot state Blinks very slowly 0 5Hz update in progress 3 EtherNet IP comm green It blinks when EtherNet IP communica...

Страница 10: ...verters must be made using Connector3 and or Connector4 of the HD67620 A1 with at least a Category 5E cable The maximum length of the cable should not exceed 100m The cable has to conform to the T568...

Страница 11: ...runs with Windows called SW67627 It is downloadable on the site www adfweb com and its operation is described in this document This manual is referenced to the last version of the software present on...

Страница 12: ...iguration A device s configuration can also be imported or exported To clone the configurations of a programmable S7comm EtherNet IP Slave Converter in order to configure another device in the same ma...

Страница 13: ...the language of the software and check the updatings for the compositor In the section Language it is possible to change the language of the software In the section Connection Options it is possible t...

Страница 14: ...omm EtherNet IP Slave Document code MN67627_ENG Revision 1 000 Page 14 of 30 In the section Software Settings it is possible to enable disable some keyboard s commands for an easier navigation inside...

Страница 15: ...IP Address Automatically DHCP for Cable Connection is checked DHCP for LAN connection is enabled If the field Enable DNS is checked DNS protocol is enabled In the field Primary DNS the IP Address of t...

Страница 16: ...Mask the SubNet Mask for EtherNet IP side of the converter is defined In the fields Gateway the default gateway of the net is defined This feature can be enabled or disabled pressing the Check Box fi...

Страница 17: ...ss of the PLC that contains the data to be read is defined In the field PLC Port the port used for S7comm communication is defined In the field PLC Type the family of the PLC is defined In the field R...

Страница 18: ...Net IP memory array from which mapping the data read is defined In the field Start Bit is used for the Bit data It is possible to select the bit of the selected Position where mapping the data If the...

Страница 19: ...In the field DB Number the number of the DB of the PLC to write is defined In the field PLC Area the memory area where the data is located inside the PLC is defined In the field PLC Add the starting...

Страница 20: ...om S r l User Manual S7comm EtherNet IP Slave Document code MN67627_ENG Revision 1 000 Page 20 of 30 If the field Swap W is checked the words order is reversed In the field Mnemonic a description of t...

Страница 21: ...rnet cable Insert the IP 192 168 2 205 Select which operations you want to do Press the Execute update firmware button to start the upload When all the operations are OK turn OFF the Device Put Dip1 o...

Страница 22: ...program inside a Virtual Machine try to use in the main Operating System If you are using Windows Seven Vista 8 or 10 make sure that you have the administrator privileges In case you have to program...

Страница 23: ...missioning of the EtherNet IP Converter as described on the following pages was accomplished with the help of the RSLogix 5000 software of Rockwell Automation In case of using a control system from an...

Страница 24: ...the Comm Format Data SINT shall be selected as the data type RSLogix 5000 requires a configuration assembly instance Both modules do not provide a configuration assembly instance Therefore it is allo...

Страница 25: ...trial Electronic Devices ADFweb com S r l User Manual S7comm EtherNet IP Slave Document code MN67627_ENG Revision 1 000 Page 25 of 30 4 After the configuration is completed the controller tags are cre...

Страница 26: ...et IP Slave Document code MN67627_ENG Revision 1 000 Page 26 of 30 5 With RSLinks Classic Lite after have done a network scan RSWho and finding the EtherNet IP device it is possible to load the EDS fi...

Страница 27: ...ial Electronic Devices ADFweb com S r l User Manual S7comm EtherNet IP Slave Document code MN67627_ENG Revision 1 000 Page 27 of 30 MECHANICAL DIMENSIONS Figure 7 Mechanical dimensions scheme for HD67...

Страница 28: ...d combination of the following HD67627 xx Connectors Type 1 Removable 5mm Screw Terminal Enclosure Type A 1M 35mm DIN Rail mounting Device Family HD67627 S7comm EtherNet IP Slave Converter Order Code...

Страница 29: ...tion systems This symbol on the product or on its packaging indicates that this product may not be treated as household rubbish Instead it should be taken to an applicable collection point for the rec...

Страница 30: ...do the following Obtain a Product Return Number PRN from our internet support at www adfweb com Together with the request you need to provide detailed information about the problem Send the product to...

Отзывы: