background image

   

Industrial

 

Electronic Devices 

 

 

 ADFweb.com S.r.l. 

 

User Manual   

IEC 61850 Server / S7comm

 

 

Document code: MN67620_ENG     Revision 1.000   Page 1 of 28

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

User Manual 

Revision 1.000 
English

 

 

IEC 61850 Server / S7comm - Converter

  

(Order Code:  HD67620-A1) 

 

For Website information:  

www.adfweb.com?Product=HD67620

    

 

For Price information: 

www.adfweb.com?Price=HD67620-A1

 

 

Benefits and Main Features: 

 

Very easy to configure 

 

Triple Electrical isolation 

 

Temperature range: -40°C/+85°C (-40°F/+185°F) 

 

For other IEC 61850 Server products see also the following link: 

 

Converter IEC 61850 Server to  

www.adfweb.com?Product=HD67733

      

(Modbus Master) 

www.adfweb.com?Product=HD67734

      

(Modbus Slave) 

www.adfweb.com?Product=HD67735

       

(Modbus TCP Master) 

www.adfweb.com?Product=HD67736

      

(Modbus TCP Slave) 

www.adfweb.com?Product=HD67737

      

(BACnet Master) 

www.adfweb.com?Product=HD67738

      

(BACnet Slave) 

www.adfweb.com?Product=HD67739

      

(CAN) 

www.adfweb.com?Product=HD67740

      

(CANopen) 

www.adfweb.com?Product=HD67741

      

(DeviceNet Master) 

www.adfweb.com?Product=HD67742

      

(DeviceNet Slave) 

www.adfweb.com?Product=HD67743

      

(EtherNet/IP Master) 

www.adfweb.com?Product=HD67744

      

(EtherNet/IP Slave) 

www.adfweb.com?Product=HD67745

      

(J1939) 

www.adfweb.com?Product=HD67746

      

(KNX) 

www.adfweb.com?Product=HD67747

      

(MQTT) 

www.adfweb.com?Product=HD67748

      

(NMEA 0183) 

www.adfweb.com?Product=HD67749

      

(NMEA 2000) 

www.adfweb.com?Product=HD67750

      

(PROFIBUS Master) 

www.adfweb.com?Product=HD67751

      

(PROFIBUS Slave)

 

www.adfweb.com?Product=HD67752

      

(PROFINET Slave) 

www.adfweb.com?Product=HD67753

      

(SNMP Manager) 

www.adfweb.com?Product=HD67754

      

(SNMP Agent)

 

www.adfweb.com?Product=HD67755

      

(Serial) 

www.adfweb.com?Product=HD67756

      

(Ethernet) 

www.adfweb.com?Product=HD67B82

       

(PROFINET Master) 

www.adfweb.com?Product=HD67C65

      

(EnOcean) 

www.adfweb.com?Product=HD67D35

      

(LoRaWAN)

 

www.adfweb.com?Product=HD67E15

       

(EtherCAT) 

 
 

Do you have your customer protocol? Then go to: 

www.adfweb.com?Product=HD67003

 

 

Do you need to choose a device? Do you want help? 

www.adfweb.com?Cmd=helpme

 

User Manual   

 

Содержание HD67620-A1

Страница 1: ...N www adfweb com Product HD67740 CANopen www adfweb com Product HD67741 DeviceNet Master www adfweb com Product HD67742 DeviceNet Slave www adfweb com Product HD67743 EtherNet IP Master www adfweb com...

Страница 2: ...CHNICAL SUPPORT 28 RETURN POLICY 28 UPDATED DOCUMENTATION Dear customer we thank you for your attention and we remind you that you need to check that the following document is Updated Related to the p...

Страница 3: ...evice can be used only by qualified personnel strictly in accordance with the specifications Qualified personnel are persons who are familiar with the installation assembly commissioning and operation...

Страница 4: ...Industrial Electronic Devices ADFweb com S r l User Manual IEC 61850 Server S7comm Document code MN67620_ENG Revision 1 000 Page 4 of 28 EXAMPLES OF CONNECTION...

Страница 5: ...Industrial Electronic Devices ADFweb com S r l User Manual IEC 61850 Server S7comm Document code MN67620_ENG Revision 1 000 Page 5 of 28 CONNECTION SCHEME Figure 1 Connection scheme for HD67620 A1...

Страница 6: ...and S7comm bus Mountable on 35mm Rail DIN Wide power supply input range 8 24V AC or 12 35V DC Wide temperature range 40 C 85 C 40 F 185 F CONFIGURATION You need Compositor SW67620 software on your PC...

Страница 7: ...620_ENG Revision 1 000 Page 7 of 28 POWER SUPPLY The devices can be powered at 8 24V AC and 12 35V DC For more details see the two tables below VAC VDC Vmin Vmax Vmin Vmax 8V 24V 12V 35V Consumption a...

Страница 8: ...the position of the Dip1 of Dip Switch A The first with Dip1 of Dip Switch A at OFF position is used for the normal working of the device The second with Dip1 of Dip Switch A at ON position is used f...

Страница 9: ...te green Blinks slowly 1Hz Blinks quickly Boot state Blinks very slowly 0 5Hz update in progress 3 IEC61850 comm green It blinks when IEC61850 communication is running Blinks quickly Boot state Blinks...

Страница 10: ...verters must be made using Connector3 and or Connector4 of the HD67620 A1 with at least a Category 5E cable The maximum length of the cable should not exceed 100m The cable has to conform to the T568...

Страница 11: ...runs with Windows called SW67620 It is downloadable on the site www adfweb com and its operation is described in this document This manual is referenced to the last version of the software present on...

Страница 12: ...iguration A device s configuration can also be imported or exported To clone the configurations of a programmable IEC 61850 Server S7comm Converter in order to configure another device in the same man...

Страница 13: ...the language of the software and check the updatings for the compositor In the section Language it is possible to change the language of the software In the section Connection Options it is possible t...

Страница 14: ...61850 Server S7comm Document code MN67620_ENG Revision 1 000 Page 14 of 28 In the section Software Settings it is possible to enable disable some keyboard s commands for an easier navigation inside t...

Страница 15: ...ed or disabled pressing the Check Box field This feature is used for going out of the net The means of the fields for IEC61850 Server are In the fields IP Address the IP address for IEC61850 side of t...

Страница 16: ...te for the server is defined In the field Root Certificate the root of the server is defined If the field Enable Only Known Certificates is checked the converter will accept just connection from known...

Страница 17: ...ss of the PLC that contains the data to be read is defined In the field PLC Port the port used for S7comm communication is defined In the field PLC Type the family of the PLC is defined In the field R...

Страница 18: ...rnal memory array from which mapping the data read is defined In the field Start Bit is used for the Bit data It is possible to select the bit of the selected Position where mapping the data If the fi...

Страница 19: ...d In the field DB Number the number of the DB of the PLC to write is defined In the field PLC Area the memory area where the data is located inside the PLC is defined In the field PLC Add the starting...

Страница 20: ...om S r l User Manual IEC 61850 Server S7comm Document code MN67620_ENG Revision 1 000 Page 20 of 28 If the field Swap W is checked the words order is reversed In the field Mnemonic a description of th...

Страница 21: ...the field Name the name of the IEC 61850 variable is defined In the field Type the data format of the IEC 61850 variable is defined If the field Read Only is checked the IEC 61850 variable is just in...

Страница 22: ...ertificate button from the Main Window of SW67620 Fig 2 the Definition the list of Known Certificates window appears Fig 6 The data of the columns have the following meanings If the field Enable is ch...

Страница 23: ...rnet cable Insert the IP 192 168 2 205 Select which operations you want to do Press the Execute update firmware button to start the upload When all the operations are OK turn OFF the Device Put Dip1 o...

Страница 24: ...program inside a Virtual Machine try to use in the main Operating System If you are using Windows Seven Vista 8 or 10 make sure that you have the administrator privileges In case you have to program m...

Страница 25: ...rial Electronic Devices ADFweb com S r l User Manual IEC 61850 Server S7comm Document code MN67620_ENG Revision 1 000 Page 25 of 28 MECHANICAL DIMENSIONS Figure 9 Mechanical dimensions scheme for HD67...

Страница 26: ...d combination of the following HD67620 xx Connectors Type 1 Removable 5mm Screw Terminal Enclosure Type A 1M 35mm DIN Rail mounting Device Family HD67620 IEC 61850 Server S7comm Converter Order Code H...

Страница 27: ...ion systems This symbol on the product or on its packaging indicates that this product may not be treated as household rubbish Instead it should be taken to an applicable collection point for the recy...

Страница 28: ...do the following Obtain a Product Return Number PRN from our internet support at www adfweb com Together with the request you need to provide detailed information about the problem Send the product to...

Отзывы: