background image

   

Industrial

 

Electronic Devices 

 

 

 ADFweb.com Srl – IT31010 – Mareno – Treviso                                                      INFO:  

www.adfweb.com

      Phone +39.0438.30.91.31            

 

User Manual   

NMEA 0183 / Modbus TCP Slave - Converter

 

 

Document code: MN67617_ENG     Revision 1.000    Page 1 of 30 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

For other Gateways / Bridges: 

Serial / Modbus TCP - converter 

See also the following links: 

www.adfweb.com?product=HD67521

 

(Modbus TCP Slave) 

 

CAN bus to Modbus 

See also the following links: 

www.adfweb.com?product=HD67011

 

(Modbus RTU Master) 

www.adfweb.com?product=HD67012

 

(Modbus RTU Slave) 

www.adfweb.com?product=HD67514

 

(Modbus TCP Master) 

www.adfweb.com?product=HD67515

 

(Modbus TCP Server) 

 
 

Do you have an your customer protocol? 

See the following links: 

www.adfweb.com?Product=HD67003

 

 
Do you need to choose a device? do you want help? 

Ask it to the following link: 

www.adfweb.com?Cmd=helpme

 

 
 

 

User Manual 

Revision 1.000 
English 

 

NMEA 0183 / Modbus TCP Slave - 
Converter 

(Order Code: HD67617-A1, HD67617-422-A1) 

 
for Website information:  

www.adfweb.com?Product=HD67617

  

 
for Price information: 

www.adfweb.com?Price=HD67617-A1

 

www.adfweb.com?Price=HD67617-422-A1

 

 

 
Benefits and Main Features: 

 

Very easy to configure 

 

32mm Rail DIN mount 

 

Wide supply input range 

Temperature range: -40°C/+85°C (-40°F/+185°F) 

User Manual   

 

Содержание HD67617-422-A1

Страница 1: ...ww adfweb com product HD67514 Modbus TCP Master www adfweb com product HD67515 Modbus TCP Server Do you have an your customer protocol See the following links www adfweb com Product HD67003 Do you nee...

Страница 2: ...RDS 29 WARRANTIES AND TECHNICAL SUPPORT 30 RETURN POLICY 30 UPDATED DOCUMENTATION Dear customer we thank you for your attention and we remind you that you need to check that the following document is...

Страница 3: ...s mechanical interlocks etc QUALIFIED PERSONNEL The device can be used only by qualified personnel strictly in accordance with the specifications Qualified personnel are persons who are familiar with...

Страница 4: ...nic Devices ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 User Manual NMEA 0183 Modbus TCP Slave Converter Document code MN67617_ENG Revision 1 000 Page 4 of 30 EXAM...

Страница 5: ...com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 User Manual NMEA 0183 Modbus TCP Slave Converter Document code MN67617_ENG Revision 1 000 Page 5 of 30 CONNECTION SCHEME Figur...

Страница 6: ...ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 User Manual NMEA 0183 Modbus TCP Slave Converter Document code MN67617_ENG Revision 1 000 Page 6 of 30 Figure 1b Connec...

Страница 7: ...cteristics electrical isolation between NMEA 0183 Modbus TCP Power Supply Modbus TCP Power Supply NMEA 0183 Multiple independent NMEA 0183 lines Mountable on Rail DIN Wide power supply input range 8 2...

Страница 8: ...ument code MN67617_ENG Revision 1 000 Page 8 of 30 POWER SUPPLY The devices can be powered at 8 24V AC and 12 35V DC The consumption depends to the code of the device For more details see the two tabl...

Страница 9: ...of the Dip2 of Dip Switch A The first with Dip2 of Dip Switch A at OFF position is used for the normal working of the device The second with Dip2 of Dip Switch A at ON position is used for uploading...

Страница 10: ...w LED Normal Mode Boot Mode 1 Device State green Blinks slowly 1Hz Blinks quickly Boot state Blinks very slowly 0 5Hz update in progress 2 Ethernet Link green ON Ethernet cable connected OFF Ethernet...

Страница 11: ...120 resistor it is necessary to put ON dip 1 like in figure The maximum length of the cable should be 1200m 4000 feet Here some codes of cables Belden p n 8132 2x 28AWG stranded twisted pairs conducto...

Страница 12: ...31 User Manual NMEA 0183 Modbus TCP Slave Converter Document code MN67617_ENG Revision 1 000 Page 12 of 30 RS422 For terminate the RS422 line with a 120 resistor it is necessary to put ON dip 1 for T...

Страница 13: ...1 User Manual NMEA 0183 Modbus TCP Slave Converter Document code MN67617_ENG Revision 1 000 Page 13 of 30 RS232 The connection from RS232 socket to a serial port must be made with a Null Modem cable a...

Страница 14: ...ETHERNET The Ethernet connection must be made using Connector5 of HD67617 with at least a Category 5E cable The maximum length of the cable should not exceed 100m The cable has to conform to the T568...

Страница 15: ...ITOR SW67617 To configure the Converter use the available software that runs with Windows called SW67617 It is downloadable on the site www adfweb com and its operation is described in this document T...

Страница 16: ...ich contains the entire device s configuration A device s configuration can also be imported or exported To clone the configurations of a programmable NMEA 0183 Modbus TCP Slave Converter in order to...

Страница 17: ...ton there is the possibility to change the language of the software and check the updatings for the compositor In the section Language it is possible to change the language of the software In the sect...

Страница 18: ...8 30 91 31 User Manual NMEA 0183 Modbus TCP Slave Converter Document code MN67617_ENG Revision 1 000 Page 18 of 30 In the section Software Settings it is possible to enable disable some keyboard s com...

Страница 19: ...code MN67617_ENG Revision 1 000 Page 19 of 30 SET COMMUNICATION By Pressing the Set Communication button from the main window for SW67617 Fig 2 the window Set Communication appears Fig 3 The window is...

Страница 20: ...d pressing the Check Box field This feature is used for going out of the net In the field Port the TCP port to use for Modbus TCP communication is defined RS232 This section is used to define the main...

Страница 21: ...Figure 3d Set Communication RS485 2 window RS485 2 This section is used to define the main parameters of RS485 2 line The means of the fields are If the field Enable RS485 2 is checked the serial port...

Страница 22: ...wing meanings If the field Enable is checked the NMEA 0183 sentence is enabled In the field Serial Channel the serial port from which the sentence will be received is defined In the field Sentence the...

Страница 23: ...evice Connect the Ethernet cable Insert the IP 192 168 2 205 Select which operations you want to do Press the Execute update firmware button to start the upload When all the operations are OK turn OFF...

Страница 24: ...stance Try to repeat the operations for the updating Try with another PC Try to restart the PC Check the LAN settings If you are using the program inside a Virtual Machine try to use in the main Opera...

Страница 25: ...p is created automatically In relation to the configuration defined it is possible to have two different maps Data in reading Type Address Function Description Input Register 0 03 Position 0 1 of inte...

Страница 26: ...IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 User Manual NMEA 0183 Modbus TCP Slave Converter Document code MN67617_ENG Revision 1 000 Page 26 of 30 Figure 7a Mechanical dimension...

Страница 27: ...com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 User Manual NMEA 0183 Modbus TCP Slave Converter Document code MN67617_ENG Revision 1 000 Page 27 of 30 Figure 7b Mechanical...

Страница 28: ...5mm DIN Rail mounting Serial Ports None 1 x RS232 2 x RS485 RS422 1 x RS232 1 x RS485 1 x RS422 Device Family HD67617 NMEA 0183 Modbus TCP Slave Converter Order Code HD67617 A1 NMEA 0183 Modbus TCP Sl...

Страница 29: ...uropean countries with separate collection systems This symbol on the product or on its packaging indicates that this product may not be treated as household rubbish Instead it should be taken to an a...

Страница 30: ...wish to exchange or repair it please do the following Obtain a Product Return Number PRN from our internet support at www adfweb com Together with the request you need to provide detailed information...

Отзывы: