DMX DEFAULT VALUE: 
 

By pressing the “

DMX Default Value

” button from the main window for SW67517 (Fig. 2) the “DMX Default Value” window appears (Fig. 4). 

In this section it is possible to define the default value for each channel of the DMX array when the converter is turned ON. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 

Figure 4: “DMX Default Value” window

 

Содержание HD67517-B2

Страница 1: ...041 SNMP Manager www adfweb com Product HD67046 Serial www adfweb com Product HD67509 Modbus TCP Slave www adfweb com Product HD67518 Modbus Master www adfweb com Product HD67519 Modbus TCP Master www...

Страница 2: ...UPPORT 24 RETURN POLICY 24 UPDATED DOCUMENTATION Dear customer we thank you for your attention and we remind you that you need to check that the following document is Updated Related to the product yo...

Страница 3: ...ce can be used only by qualified personnel strictly in accordance with the specifications Qualified personnel are persons who are familiar with the installation assembly commissioning and operation of...

Страница 4: ...Industrial Electronic Devices ADFweb com S r l User Manual DMX Modbus Slave Document code MN67517_ENG Revision 1 000 Page 4 of 24 EXAMPLE OF CONNECTION...

Страница 5: ...Industrial Electronic Devices ADFweb com S r l User Manual DMX Modbus Slave Document code MN67517_ENG Revision 1 000 Page 5 of 24 CONNECTION SCHEME Figure 1 Connection scheme for HD67517 B2...

Страница 6: ...teristics Triple isolation between Modbus Power Supply Modbus DMX Power Supply DMX Two directional information between Modbus bus and DMX bus Mountable on 35mm Rail DIN Wide power supply input range 8...

Страница 7: ...7_ENG Revision 1 000 Page 7 of 24 POWER SUPPLY The devices can be powered at 8 24V AC and 12 35V DC For more details see the two tables below VAC VDC Vmin Vmax Vmin Vmax 8V 24V 12V 35V Consumption at...

Страница 8: ...he position of the Dip1 of Dip Switch A The first with Dip1 of Dip Switch A at OFF position is used for the normal working of the device The second with Dip1 of Dip Switch A at ON position is used for...

Страница 9: ...Hz ON Device powered OFF Device not powered 2 Modbus communication yellow Blinks when a Modbus request is received Blinks quickly Boot state Blinks very slowly 0 5Hz update in progress 3 DMX communica...

Страница 10: ...dip 1 like in figure The maximum length of the cable should be 1200m 4000 feet Here some codes of cables Belden p n 8132 2x 28AWG stranded twisted pairs conductor foil shield braid shield Belden p n 8...

Страница 11: ...ble should be 1200m 4000 feet Here some codes of cables Belden p n 8132 2x 28AWG stranded twisted pairs conductor foil shield braid shield Belden p n 82842 2x 24AWG stranded twisted pairs conductor fo...

Страница 12: ...Ethernet connection must be made using Connector2 of HD67517 B2 with at least a Category 5E cable The maximum length of the cable should not exceed 100m The cable has to conform to the T568 norms rel...

Страница 13: ...with Windows called SW67517 It is downloadable from the site www adfweb com and its operation is described in this document this manual is referenced to the last version of the software present on ou...

Страница 14: ...iguration A device s configuration can also be imported or exported To clone the configurations of a Programmable DMX Modbus slave Converter in order to configure another device in the same manner it...

Страница 15: ...language of the software and check the updatings for the compositor In the section Language it is possible to change the language of the software In the section Connection Options it is possible to c...

Страница 16: ...DMX Modbus Slave Document code MN67517_ENG Revision 1 000 Page 16 of 24 In the section Software Settings it is possible to enable disable some keyboard s commands for an easier navigation inside the...

Страница 17: ...he serial port to use is defined In the field Baudrate the baudrate for the serial line is defined In the field Parity the parity of the serial line is defined In the field Stop Bits the number of Sto...

Страница 18: ...0 Page 18 of 24 DMX DEFAULT VALUE By pressing the DMX Default Value button from the main window for SW67517 Fig 2 the DMX Default Value window appears Fig 4 In this section it is possible to define th...

Страница 19: ...cable Insert the IP 192 168 2 205 Select which operations you want to do Press the Execute update firmware button to start the upload When all the operations are OK turn OFF the Device Put Dip1 of Di...

Страница 20: ...estart the PC Check the LAN settings Check the Wi Fi settings If you are using the program inside a Virtual Machine try to use in the main Operating System If you are using Windows Seven Vista 8 or 10...

Страница 21: ...ustrial Electronic Devices ADFweb com S r l User Manual DMX Modbus Slave Document code MN67517_ENG Revision 1 000 Page 21 of 24 MECHANICAL DIMENSIONS Figure 7 Mechanical dimensions scheme for HD67517...

Страница 22: ...by a valid combination of the following HD67517 B 2 Connectors Type 2 Fixed 5mm Screw Terminal Enclosure Type B 2M 35mm DIN Rail mounting Device Family HD67517 DMX Modbus slave Converter Order Code H...

Страница 23: ...systems This symbol on the product or on its packaging indicates that this product may not be treated as household rubbish Instead it should be taken to an applicable collection point for the recycli...

Страница 24: ...he following Obtain a Product Return Number PRN from our internet support at www adfweb com Together with the request you need to provide detailed information about the problem Send the product to the...

Отзывы: