POWER SUPPLY: 

 
The devices can be powered at 8…24V AC and 12…35V DC. For more details see the two tables below. 
 

VAC 

 

VDC 

 

Vmin 

Vmax 

Vmin 

Vmax 

8V 

24V 

12V 

35V 

 
 
 

 

 

 

Consumption at 24V DC: 

Device 

Consumption [W/VA] 

HD67671-IP-2-A1 

3.5 

HD67671-IP-4-A1 

3.5 

HD67671-MSTP-2-A1 

3.5 

 
 
 
 
 
 
 

  
 
 

Caution:  Not reverse the polarity power

 

HD67235-A1 

 

HD67235-A3 

 

HD67235-A4 

 

Содержание HD67235-A1

Страница 1: ... Main Features Very easy to configure Triple electrical isolation Ethernet programmation Temperature range 40 C 85 C 40 F 185 F For others Gateways Bridges CANopen to DeviceNet See also the following links www adfweb com Product HD67134 CAN bus to Modbus See also the following links www adfweb com Product HD67011 Modbus RTU Master www adfweb com Product HD67012 Modbus RTU Slave www adfweb com Prod...

Страница 2: ...TED DOCUMENTATION Dear customer we thank you for your attention and we remind you that you need to check that the following document is Updated Related to the product you own To obtain the most recently updated document note the document code that appears at the top right hand corner of each page of this document With this Document Code go to web page www adfweb com download and search for the cor...

Страница 3: ...he device can be used only by qualified personnel strictly in accordance with the specifications Qualified personnel are persons who are familiar with the installation assembly commissioning and operation of this equipment and who have appropriate qualifications for their job RESIDUAL RISKS The device is state of the art and is safe The instruments can represent a potential hazard if they are inap...

Страница 4: ...Industrial Electronic Devices ADFweb com S r l User Manual DeviceNet Slave CAN Converter Document code MN67235_ENG Revision 2 000 Page 4 of 26 EXAMPLE OF CONNECTION ...

Страница 5: ...ndustrial Electronic Devices ADFweb com S r l User Manual DeviceNet Slave CAN Converter Document code MN67235_ENG Revision 2 000 Page 5 of 26 CONNECTION SCHEME Figure 1a Connection scheme for HD67235 A1 ...

Страница 6: ...Industrial Electronic Devices ADFweb com S r l User Manual DeviceNet Slave CAN Converter Document code MN67235_ENG Revision 2 000 Page 6 of 26 Figure 1b Connection scheme for HD67235 A3 ...

Страница 7: ...Industrial Electronic Devices ADFweb com S r l User Manual DeviceNet Slave CAN Converter Document code MN67235_ENG Revision 2 000 Page 7 of 26 Figure 1c Connection scheme for HD67235 A4 ...

Страница 8: ...Two directional information between BACnet bus and DeviceNet bus Mountable on 35mm Rail DIN Wide power supply input range 8 24V AC or 12 35V DC Wide temperature range 40 C 85 C 40 F 185 F CONFIGURATION You need Compositor SW67235 software on your PC in order to perform the following Define the parameter of CAN line Define the parameter of Devicenet line Define the CAN frames that the Converter can...

Страница 9: ... of 26 POWER SUPPLY The devices can be powered at 8 24V AC and 12 35V DC For more details see the two tables below VAC VDC Vmin Vmax Vmin Vmax 8V 24V 12V 35V Consumption at 24V DC Device Consumption W VA HD67671 IP 2 A1 3 5 HD67671 IP 4 A1 3 5 HD67671 MSTP 2 A1 3 5 Caution Not reverse the polarity power HD67235 A1 HD67235 A3 HD67235 A4 ...

Страница 10: ...irst with Dip2 of Dip Switch A at OFF position is used for the normal working of the device The second with Dip2 of Dip Switch A at ON position is used for uploading the Project and or Firmware For the operations to follow for the updating see UPDATE DEVICE section According to the functioning mode the LEDs will have specifics functions see LEDS section Warning Dip1 of Dip Switch A must be at ON p...

Страница 11: ...ice state green Blinks slowly 1Hz Blinks quickly Boot state Blinks very slowly 0 5Hz update in progress 2 Link Ethernet ON Ethernet cable connected OFF Ethernet cable disconnected ON Ethernet cable connected OFF Ethernet cable disconnected 3 CAN comm Blinks quickly when receive a CAN frame defined in the Compositor Blinks quickly Boot state Blinks very slowly 0 5Hz update in progress 4 DeviceNet c...

Страница 12: ...26 CAN For terminate the CAN line with a 120Ω resistor it is necessary that the Dip1 of Dip Switch B is at ON position Cable characteristics DC parameter Impedance 70 Ohm m AC parameters Impedance 120 Ohm m Delay 5 ns m Length Baud Rate bps Length MAX m 10 K 5000 20 K 2500 50 K 1000 100 K 650 125 K 500 250 K 250 500 K 100 800 K 50 1000 K 25 ...

Страница 13: ...0 Ohm m Delay 5 ns m Length Baud Rate bps Length MAX m 125 K 500 250 K 250 500 K 100 ETHERNET The Ethernet port is used for programming the device The Ethernet connection must be made using Connector4 of HD67235 with at least a Category 5E cable The maximum length of the cable should not exceed 100m The cable has to conform to the T568 norms relative to connections in cat 5 up to 100 Mbps To conne...

Страница 14: ...that runs with Windows called SW67235 It is downloadable from the site www adfweb com and its operation is described in this document this manual is referenced to the last version of the software present on our web site The software works with MSWindows XP Vista Seven 8 32 64bit When launching the SW67235 the window below appears Fig 2 Note It is necessary to have installed Net Framework 4 Figure ...

Страница 15: ...s configuration A device s configuration can also be imported or exported To clone the configurations of a Programmable DeviceNet slave CAN Converter in order to configure another device in the same manner it is necessary to maintain the folder and all its contents To clone a project in order to obtain a different version of the project it is sufficient to duplicate the project folder with another...

Страница 16: ...nge the language of the software and check the updatings for the compositor In the section Language it is possible to change the language of the software In the section Connection Options it is possible to check if there are some updatings of the software compositor in ADFweb com website Checking the option Check Software Update at Start of Program the SW67235 check automatically if there are upda...

Страница 17: ...oftware Settings it is possible to enable or disable some addictional functions By checking the field Jump into next field in the tables by pressing the Enter Key is possible to jump to the next cell with the Enter button By checking the field Enable Auto Size of Table Columns by Double Click is possible to re size the columns in the tables with a double click ...

Страница 18: ... the CAN section are In the field Baudrate the CAN baudrate is defined The means of the fields for the DeviceNet section are In the field ID Device insert the Address you want to assing to the Converter In the field Baudrate the DeviceNet baud rate is defined In the field Number Byte IN the number of byte from the DeviceNet to the Converter is defined at maximum it is possible to use 455 byte In t...

Страница 19: ...se for this Cob ID or 2 0A 11 bits or 2 0B 29 bits In the field Dimension insert the number of byte of the COB from 1 to 8 The field TimeOut is used for put at zero the data into DeviceNet if the CAN frame don t arrives with a frequency less than the time expressed in the field If the value in the field is 0 means that you don t want to use this feature and so the value is never deleted In the fie...

Страница 20: ...for this Cob ID or 2 0A 11 bits or 2 0B 29 bits In the field Dimension insert the number of byte of the COB from 1 to 8 If the field On Change is checked the CAN frame is sent when one of the data is changed If the field On Timer is checked the CAN frame is sent cyclically In the field Timer insert the interval used for the On Timer The time is in milliseconds In the fields Byte1 Byte2 Byte3 Byte4...

Страница 21: ...ctual IP address of the device you have to use this procedure Turn off the Device Put Dip1 of Dip Switch A in ON position Turn on the device Connect the Ethernet cable Insert the IP 192 168 2 205 Select update options Firmware Configuration Press the Execute update firmware button to start the upload When all the operations are OK turn off the Device Put Dip1 of Dip Switch A at OFF position Turn o...

Страница 22: ...version of the software if it is the first time it is better you do the update of the Firmware in the HD67235 A1 device Note When you receive the device for the first time you also have to update the Firmware in the HD67235 A1 device Warning If Fig 7 appears when you try to do the Update try these points before seeking assistance Try to repeat the operations for the updating Try with another PC Tr...

Страница 23: ...ceNet Slave CAN Converter Document code MN67235_ENG Revision 2 000 Page 23 of 26 MECHANICAL DIMENSIONS Figure 8a Mechanical dimensions scheme for HD67235 A1 Figure 8b Mechanical dimensions scheme for HD67235 A3 Figure 8c Mechanical dimensions scheme for HD67235 A4 ...

Страница 24: ...onnectors 4 Mini Fit Connectors Enclosure Type A 1M 35mm DIN Rail mounting Device Family HD67235 DeviceNet slave CAN Converter Order Code HD67235 A1 DeviceNet slave CAN Converter Removable screw terminal connectors Order Code HD67235 A3 DeviceNet slave CAN Converter M12 connectors Order Code HD67235 A4 DeviceNet slave CAN Converter Mini Fit connectors ACCESSORIES Order Code AC34001 35mm Rail DIN P...

Страница 25: ...lection systems This symbol on the product or on its packaging indicates that this product may not be treated as household rubbish Instead it should be taken to an applicable collection point for the recycling of electrical and electronic equipment If the product is disposed correctly you will help prevent potential negative environmental factors and impact of human health which could otherwise be...

Страница 26: ...ase do the following Obtain a Product Return Number PRN from our internet support at www adfweb com Together with the request you need to provide detailed information about the problem Send the product to the address provided with the PRN having prepaid the shipping costs shipment costs billed to us will not be accepted If the product is within the warranty of twelve months it will be repaired or ...

Отзывы: