ADF Web HD67213 Скачать руководство пользователя страница 1

   

Industrial

 

Electronic Devices 

 

 

 ADFweb.com Srl – IT31010 – Mareno – Treviso                                                      INFO:  

www.adfweb.com

      Phone +39.0438.30.91.31            

 

User Manual   

J1939 to Ethernet 

 

 

Document code: MN67213_ENG     Revision 1.002    Page 1 of 16 

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 
 
 
 
 

 

 

 

 
 
 
 
 
 
 
 
 
 
 
                                                                                          
 
 
 
 
 
 
 
 

 

User Manual 

Revision 1.002 
English 

 

Gateway / Adapter 
J1939 to Ethernet  

(Order Code: HD67213 – HD67213M) 

 
for Website information:  

www.adfweb.com?Product=HD67213

 

www.adfweb.com?Product=HD67213M

 

 

 

for Price information: 

www.adfweb.com?Price=HD67213

 

www.adfweb.com?Price=HD67213M

 

 

Benefits and Main Features: 

 

 

Mountable on Rail DIN 

 

TCP/UDP protocols changeable with software 

 

Easy to use software configuration 

 

Industrial temperature range:  

-30 °C / 70°C (-22°F / 158°F) 

For others Converter / Adapter: 

RS232 / RS485 

See also the following link: 

www.adfweb.com?Product=HD67118

 

 

USB / RS485 

See also the following link: 

www.adfweb.com?Product=HD67119

 

 
 
Do you have an your customer protocol? 

See the following link: 

www.adfweb.com?Product=HD67003

 

 
Do you need to choose a device? do you want help? 

Ask it to the following link: 

www.adfweb.com?Cmd=helpme

 

 

Similiar 
Products 

HD67213 

HD67213M 

Содержание HD67213

Страница 1: ...ice HD67213 www adfweb com Price HD67213M Benefits and Main Features Mountable on Rail DIN TCP UDP protocols changeable with software Easy to use software configuration Industrial temperature range 30...

Страница 2: ...llowing document is Updated Related to the product you own To obtain the most recently updated document note the document code that appears at the top right hand corner of each page of this document W...

Страница 3: ...vices ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 User Manual J1939 to Ethernet Document code MN67213_ENG Revision 1 002 Page 3 of 16 CONNECTION SCHEME Figure 1 Co...

Страница 4: ...onic Devices ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 User Manual J1939 to Ethernet Document code MN67213_ENG Revision 1 002 Page 4 of 16 Figure 2 Connection sc...

Страница 5: ...evision 1 002 Page 5 of 16 CHARACTERISTICS The Configurable J1939 Slave to Ethernet gateway allow the following TCP UDP Ethernet protocols changeable with software Mountable on Rail DIN Temperature ra...

Страница 6: ...213 software on your PC in order to perform the following Define the parameter of the J1939 bus Define the parameter of the Ethernet USE OF COMPOSITOR SW67213 To configure the Gateway use the availabl...

Страница 7: ...imported and exported To clone the configurations of a Programmable J1939 to Ethernet Gateway in order to configure another device in the same manner it is necessary to maintain the folder and all its...

Страница 8: ...field TimeOut Data insert a time when this time is elapsed the data isn t reliable and in the Modbus register you can read FFFF If the field Peer to Peer is checked the gateway accept any ID that have...

Страница 9: ...ead from Ethernet to J1939 it is an identifier In the field Source Address insert the address of the device that send the frame If the field Multi Frame is checked the Transport Protocol is enabled fo...

Страница 10: ...ad the parameters or update the firmware in the gateway follow these instructions Connect the Ethernet cable from your PC to the gateway Insert the IP address of HD67213 and press the Ping Button Pres...

Страница 11: ...em cable from your PC to the gateway Insert the Boot Jumper see the Fig 1 for more info Turn on the device Check the BOOT Led It must to blink quickly See the Fig 1 for more info Select COM port and p...

Страница 12: ...sion 1 002 Page 12 of 16 CHARACTERISTICS OF THE CABLES The connection at Ethernet socket must be with a Ethernet Cable with a RJ45 Plug The connection from RS232 socket to a serial port example one fr...

Страница 13: ...Priority 4 Data Page 5 PGN Hi 6 PGN Lo 7 Source Address 8 15 Data Byte 8 is the higher byte 15 is the lower A single frame is composed by 13 bytes byte 3 to byte 15 Now if the Number of frame to send...

Страница 14: ...e these Byte Number Description 1 Read Write Identifier Read 0x01 Write 0x02 2 Starting Address Hi 3 Starting Address Lo 4 Number of Byte to read Hi 5 Number of Byte to read Lo The Bytes that composed...

Страница 15: ...6 MECHANICAL DIMENSIONS ORDER CODE Order Code HD67213 Gateway J1939 to Ethernet ACCESSORIES Order Code AC34001 Rail DIN Power Supply 220 240V AC 50 60Hz 12 V AC Order Code AC34002 Rail DIN Power Suppl...

Страница 16: ...ww adfweb com Together with the request you need to provide detailed information about the problem 2 Send the product to the address provided with the PRN having prepaid the shipping costs shipment co...