LEDS: 

 
The device has got five LEDs that are used to give information of the functioning status. 
The various meanings of the LEDs are described in the table below.

 

 

LED 

Normal Mode 

Boot Mode 

1: Device state (green) 

Blinks slowly (~1Hz) 

Blinks quickly 

2: wM-Bus comm. 
(green) 

Blinks quickly when data on 
wM-Bus arrives 

Blinks quickly 

3: Not used (green)  

OFF 

Blinks quickly 

4: Ethernet comm. 

Blinks quickly when data on 
Ethernet is transmitted 

Blinks quickly 

5: Link Ethernet (green) 

ON:

 Ethernet cable connected 

OFF:

 Ethernet cable disconnected 

ON:

 Ethernet cable connected 

OFF:

 Ethernet cable disconnected 

 
 

Содержание HD67084-B2-169MHz

Страница 1: ...erter M Bus Wireless to www adfweb com Product HD67082 Modbus Slave www adfweb com Product HD67083 Modbus TCP Slave Converter M Bus to www adfweb com Product HD67021 RS232 www adfweb com Product HD670...

Страница 2: ...DOCUMENTATION Dear customer we thank you for your attention and we remind you that you need to check that the following document is Updated Related to the product you own To obtain the most recently...

Страница 3: ...evice can be used only by qualified personnel strictly in accordance with the specifications Qualified personnel are persons who are familiar with the installation assembly commissioning and operation...

Страница 4: ...Industrial Electronic Devices ADFweb com S r l User Manual M Bus Wireless Ethernet Document code MN67084_ENG Revision 1 100 Page 4 of 22 EXAMPLE OF CONNECTION...

Страница 5: ...dustrial Electronic Devices ADFweb com S r l User Manual M Bus Wireless Ethernet Document code MN67084_ENG Revision 1 100 Page 5 of 22 CONNECTION SCHEME Figure 1 Connection scheme for HD67084 B2 xxxMH...

Страница 6: ...Bus Possibility to filter the wM Bus meters to read Available wM Bus frequency 169 MHz or 433 Mhz or 868 MHz in relation to the order code Mountable on 35mm Rail DIN Wide power supply input range 15...

Страница 7: ...ge 7 of 22 POWER SUPPLY The devices can be powered at 15 21V AC and 18 35V DC The consumption depends to the code of the device For more details see the two tables below VAC VDC Vmin Vmax Vmin Vmax 15...

Страница 8: ...the position of the Dip1 of Dip Switch A The first with Dip1 of Dip Switch A at OFF position is used for the normal working of the device The second with Dip1 of Dip Switch A at ON position is used f...

Страница 9: ...LEDs are described in the table below LED Normal Mode Boot Mode 1 Device state green Blinks slowly 1Hz Blinks quickly 2 wM Bus comm green Blinks quickly when data on wM Bus arrives Blinks quickly 3 N...

Страница 10: ...e should not exceed 100m The cable has to conform to the T568 norms relative to connections in cat 5 up to 100 Mbps To connect the device to an Hub Switch is recommended the use of a straight cable to...

Страница 11: ...runs with Windows called SW67084 It is downloadable from the site www adfweb com and its operation is described in this document this manual is referenced to the last version of the software present o...

Страница 12: ...iguration A device s configuration can also be imported or exported To clone the configurations of a Programmable M Bus Wireless Ethernet Converter in order to configure another device in the same man...

Страница 13: ...the language of the software and check the updatings for the compositor In the section Language it is possible to change the language of the software In the section Connection Options it is possible t...

Страница 14: ...wM Bus Access See page 15 If the field Received Signal Strenght Indication is checked it is possible to add a byte at the end of the Ethernet frame to indicate the Strenght of the wM Bus signal dBm If...

Страница 15: ...thernet In the field Manufacturer ID the Manufacturer ID of the wM Bus node is defined In the field Address the ID of the wM Bus node is defined In the field Version the version of the wM Bus node is...

Страница 16: ...Press the Next button Select which operations you want to do Press the Execute update firmware button to start the upload When all the operations are OK turn off the Device Put Dip2 of Dip Switch A a...

Страница 17: ...nother PC Try to restart the PC Check the LAN settings If you are using the program inside a Virtual Machine try to use in the main Operating System If you are using Windows Seven Vista 8 or 10 make s...

Страница 18: ...ication and Link Quality Indication The frame sent by the wM Bus node is 44 A2 05 26 01 00 26 01 1B 7A F6 00 00 20 2F 2F 02 66 ED 00 01 FB 1B 2F 2F 2F 2F 2F 2F 2F hex The converter will send this Ethe...

Страница 19: ...Electronic Devices ADFweb com S r l User Manual M Bus Wireless Ethernet Document code MN67084_ENG Revision 1 100 Page 19 of 22 MECHANICAL DIMENSIONS Figure 7 Mechanical dimensions scheme for HD67084...

Страница 20: ...s Wireless communication 433 MHz 868MHz M Bus Wireless communication 868 MHz Connectors Type 2 Fixed Screw Terminal Enclosure Type B Modulbox 4M 35mm DIN Rail mounting Device Family HD67084 M Bus Wire...

Страница 21: ...ion systems This symbol on the product or on its packaging indicates that this product may not be treated as household rubbish Instead it should be taken to an applicable collection point for the recy...

Страница 22: ...do the following Obtain a Product Return Number PRN from our internet support at www adfweb com Together with the request you need to provide detailed information about the problem Send the product to...

Отзывы: