Industrial
Electronic Devices
ADFweb.com S.r.l.
User Manual
M-Bus Wireless / Ethernet
Document code: MN67084_ENG Revision 1.100 Page 6 of 22
CHARACTERISTICS:
The HD67084-B2-xxxMHz are converters from wM-Bus to Ethernet and vice-versa.
They allows the following characteristics:
Electrical isolation between Ethernet and M-Bus;
Possibility to filter the wM-Bus meters to read;
Available wM-Bus frequency: 169 MHz or 433 Mhz or 868 MHz (in relation to the order code);
Mountable on 35mm Rail DIN;
Wide power supply input range: 15…21V AC or 18…35V DC;
Wide temperature range: -40°C / 85°C [-40°F / +185°F].
CONFIGURATION:
You need Compositor SW67084 software on your PC in order to perform the following:
Define the parameter of Ethernet;
Define the parameter of M-Bus Wireless line;
Define which M-Bus Wireless nodes are readable on Ethernet;
Update the device.