208474A_UG_Starter kit_TWIMO_V1.0
Adeunis RF
TWIMO RF Modules
Starter Kit
User Guide
Страница 1: ...208474A_UG_Starter kit_TWIMO_V1 0 Adeunis RF TWIMO RF Modules Starter Kit User Guide ...
Страница 2: ...orm 7 4 2 Turn on the system 7 5 Running the evaluation 8 5 1 Start up screen 8 5 2 Home screen 9 5 3 Select the type of module 9 5 4 Modify the configuration 9 5 4 1 RF Power 9 5 4 2 RF data rate 10 5 4 3 Channel frequency 10 6 Test mode 11 6 1 TX RX mode 11 6 2 Received level mode 12 6 3 Scanner mode 13 6 4 USB mode 14 6 5 Running screen 14 6 6 General notes 14 7 Verify or Evaluate an installati...
Страница 3: ...3 208474A_UG_Starter kit_TWIMO_V1 0 English ...
Страница 4: ...arge Partially da maged circuits can function erroneously leading to misleading results Observe ESD precautions at all times when handling this product Documents This document and any copy or extract of it can t be disclosed without Adeunis rf s formal agreement This document is subject to change without notice All trademarks mentioned in this guide are the property of their respective owners ADEU...
Страница 5: ...asily measure sensitivity output power and other RF parameters The documentation can be downloaded on the Adeunis website www adeunis rf com 2 Kit content In order to perform tests with the TWIMO extension board you must use at least one Raisonance Open4 plate form received level and scanner modes or two plateforms with extension boards if you wish to run TX RX mode Each Extension board includes 1...
Страница 6: ...Open4 platform overview LCD touch screen allows to navigate into the menu USB connector power supply PC connection Joystick allows to navigate into the menu Adeunis RF extension board Raisonance target board All needed and usefull information can be found on the Raisonance website www raisonance com User manual of the OPEN4 platform can be found here Open4 manual ...
Страница 7: ...on board as showed below The module must faces you Gently push on the extension see red arrow board to insure a proper connection Be very careful when proceeding The extension socket must be held when inserting the extension board as showed with the orange arrow Re install the bottom cover and screws Install the antenna on the extension board antenna socket 4 2 Turn on the system To turn on the sy...
Страница 8: ...ils and power supply specifications When switching on the Starter kit the system will first ask you to calibrate the screen proceed When the screen calibration has been done press the one dot button to launch the Adeunis RF applica tion one dot button 5 Running the evaluation The evaluation can be ran on three different modes TX RX mode Received level mode Scanner mode Set up the Starter Kit When ...
Страница 9: ...he type of module Press the change icon A list of the available Adeunis RF extension board appears Select the proper board and press the validate icon Module type set up Set up the module Module type selection Run the evaluation USB mode 5 4 Modify the configuration 5 4 1 RF Power Press the Config icon Choose the RF Power TWIMO MP 17dBm 14dBm 10dBm TWIMO HP 27dBm 23dBm 20dBm Press the validate ico...
Страница 10: ...ta rate previously chosen the list of avai lable channels is adapted to the European regulation and standards Please refer to the table below Power RF Data Rate Available Channels frequencies 27dBm 10kbps 38 4kbps 57 6kbps 869 525MHz 23dBm 10kbps 38 4kbps 57 6kbps 869 525MHz 20dBm 10kbps 38 4kbps 57 6kbps 869 525MHz 17dBm 10kbps 38 4kbps 57 6kbps 869 525MHz 14dBm 10kbps 869 525MHz 38 4kbps 869 525...
Страница 11: ...le version Possible error messages Module init failed restart the Open4 platform Unsupported or wrong module go back to the module list and chose the one installed on the extension board Note 1 this mode forces to select one Starter kit as TX and the other as RX Note 2 particular case of TX RX and Received level modes When selecting the role Tx the Starter kit behaves as a master transmits every s...
Страница 12: ...Received level mode The received level mode allows to run a permanent test between Two Starter kits One Starter kit in RX mode and a TWIMO module installed in another device TX Mode send a frame every seconds First column TX counter Second column RSSI level of the received frames RXcnt number of frame received TXcnt number of frame emitted The lost frames can be calculated by TXcnt RXcnt The PER c...
Страница 13: ... displays Rx level and the Starter kit does not answer Second column RSSI level of the received frames RXcnt number of frame received FrameLost lost frame counter The PER can deducted by FrameLost TXcnt RSSI 98dBm RSSI level of the last frame received Max 93dBm Higher RSSI level of the frames received Min 98dBm Lower RSSI level of the frames received Note by using the pause box the Max and Min RSS...
Страница 14: ...C Check that the correct drivers are installed Clic on Reset icon if you need to reset the module Clic on Cmd Enter to enter command mode The Open4 platform is now acting as a virtual port com direct access to the TWIMO module at 115 2kbps and any type of Terminal can be used To exit the USB mode clic on the Back icon 6 5 Running screen When the evaluation is launched the Starter kit is showing a ...
Страница 15: ...p Set the TWIMO Starter kit in Scanner mode Shut down all existing transmitters Note the RSSI average level from the Scanner mode You can eventually reinitialize the RSSI Max and Min level by using the Pause box Second step Use a TWIMO module embedded in your application Set the TWIMO module in test ATT21 permanent modulated transmission Note the RSSI Min of the received frames Starter kit in Scan...
Страница 16: ...02 EN 60950 1 2001 A11 2004 EN62311 2008 EN301 489 1 v1 8 1 2008 04 EN 301 489 3 v1 4 1 2002 08 According to the RTTE Directive 99 5 EC Notes Conformity has been evaluated according to the procedure described in Annex IV of the RTTE directive Statement of opinion from a notify body N 102158 604317 1 2 Conformity has been evaluated with ARF7580AA module integrated on ADEUNIS RF TWIMO Extension Pack...