 User guide version 1.0 

 

   

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

SIGFOX RTU Module 

By Adeunis 

 

User Guide Version 1.0 

 
 

 

Document revision 

Version 

Date 

Author 

Comment 

1.0 

20/07/2019 

EMT 

Initial release 

 
 
 

 
 
 
 
 
ADEUNIS 

283 rue Louis Néel - Parc Technologique Pré Roux 38920 CROLLES - France 

Tel. : +33 (0)4 76 92 07 77 - Fax : +33 (0)4 76 04 80 87 

www.adeunis.com

   

[email protected]

 

Содержание SIGFOX

Страница 1: ...nis User Guide Version 1 0 Document revision Version Date Author Comment 1 0 20 07 2019 EMT Initial release ADEUNIS 283 rue Louis Néel Parc Technologique Pré Roux 38920 CROLLES France Tel 33 0 4 76 92 07 77 Fax 33 0 4 76 04 80 87 www adeunis com arf adeunis com ...

Страница 2: ...t information Title SIGFOX RTU by Adeunis Subtitle User Guide Version 1 0 Document type User Guide Document status This document applies to the following products Name Reference Firmware version RTU SIGFOX module ARF8119A V01 04 00 ...

Страница 3: ...ARDWARE INTERFACE 12 1 1 1 RTU interface 12 1 1 2 RTU signal description 13 1 2 SERIAL INTERFACE PROTOCOL 13 1 2 1 Command format 13 1 2 2 Implemented commands 19 1 2 3 Command execution time of RTU module 19 2 RTU FEATURES MODE DESCRIPTION 20 2 1 RTU STATE MACHINE 20 2 1 1 State diagram 20 2 1 2 Idle and Nominal mode 20 2 1 3 Command mode 20 2 2 RTU APPLICATION INTERFACE IN COMMAND MODE 21 2 2 1 ...

Страница 4: ... magnetic or optical devices manually or any by other methods is prohibited ADEUNIS reserves the right to change the technical specifications or functions of its products or to cease manufacturing any of its products or to cease technical support for one of its products without notice in writing and urges its customers to make sure that the information they have is valid ADEUNISF configuration sof...

Страница 5: ...ke it easy to separate the packaging into three types of materials cardboard box expanded polystyrene filler material and polyethylene packets foam protective sheets Your device is composed of materials that can be recycled and reused if it is dismantled by a specialist company Please observe local regulations concerning the manner in which waste packaging material used batteries and your obsolete...

Страница 6: ...s no risk of internal heating and it must not be covered with objects such as newspapers cloths curtains etc The device s aerial must be free and at least 10 cm away from any conducting material The device must never be exposed to heat sources such as heating equipment Do not place the device close to objects with naked flames such as lit candles blowtorches etc The device must not be exposed to a...

Страница 7: ...rference to other users the antenna type and its gain should be chosen so that the equivalent isotropically radiated power e i r p is not superior than necessary for successful communication WARNING FOR MOBILE DEVICE USAGE This radiation element complies with FCC RF radiation exposure limits set forth for general population This radiation element must be installed to provide a separation distance ...

Страница 8: ...nt émetteur radio peut fonctionner avec une antenne d un type et d un gain maximal ou inférieur approuvé pour l émetteur par Industrie Canada Dans le but de réduire les risques de brouillage radioélectrique à l intention des autres utilisateurs il faut choisir le type d antenne et son gain de sorte que la puissance isotrope rayonnée équivalente p i r e ne dépasse pas l intensité nécessaire à l éta...

Страница 9: ...module qui explique cette exigence Dans ce dernier cas une copie de ces instructions doit être incluse dans la demande d autorisation d équipement Identification FCC ID U3Z ARF8119 Product reference USA CANADA ARF8119A ...

Страница 10: ...tion Through AT commands Radio data rate 600bps UART configuration 115 2 kbps N 8 1 Frequency channels ISM band 902 928MHz US ISM band 915 928MHz AUS NZ RF output power 23dBm 200mW Sensitivity down to 126dBm Operating range Line Of Sight Up to 15km Operating temperature 30 C 70 C Dimensions TBD Standard compliance FCC Title 47 CFR Part 15 RSS 247 Issue 2 ...

Страница 11: ...ch provides connection to any operated network using the SIGFOX protocol It allows transmitting receiving and instantly viewing the radio frames on the used network RTU module pining 1 GND 21 Uplink trigger 2 GND 22 TP1 3 ANTENA 23 Downlink trigger 4 VCC 24 NC 5 GND 25 NC 6 NC 26 RTU READY 7 RESET 27 TP2 8 NC 28 GND 9 BOOT 29 TP3 10 UART TX 30 GND 11 NC 31 GND 12 UART RX 32 GND 13 NC 33 GND 14 NC ...

Страница 12: ...0 reset module 10 UART TX 12 UART RX 21 TX Uplink monitor Signal that indicates if an UL is in progress READ ONLY Steady state 0 1 uplink in progress 0 no uplink in progress 23 RX downlink monitor Signal that indicates if an DL is in progress READ ONLY Steady state 0 1 Rx window opened 0 Rx window closed 26 RTU READY Indicate if module is ready to receive commands on UART READ ONLY Steady state 1 ...

Страница 13: ...r an Uplink command request RTU Ready stays low for the complete IoT cycle In that case the duration may be very long many seconds 1 1 2 1 TX Uplink RX Downlink signals These two signals are signals frame activated at uplink RF transmission and downlink RF reception during IoT cycle 1 1 2 1 UART Tx an UART Rx signals These two signals allow UART communication to support the serial interface protoc...

Страница 14: ...o 0x15 NACK DATA OPTIONNEL only if ACK CRC 4 bytes depends on CMD optional Command Uplink Initiate a Uplink SOF LENGTH CMD OPTIONS DATA CMD Command 0x04 OPTIONS SIGFOX OPTIONS CTRL TEMP o CTRL Bit 0 bidir cycle if 1 Bit 1 frame OOB Bit 3 2 Nb of transmission 0 valeur du registre 1 à 3 Nb of transmission o TEMP Temperature expressed in tenths of degrees signed in addition to 2 2 octets LSB First Co...

Страница 15: ...gth error number of data except CMD 2 0 1 to 63 register index in the DATA field that caused the NACK Command ATReg Write Allows writing AT registers SOF LENGTH CMD DATA LENGTH 0x07 1 register à 0xFD 42 registers CMD Command 0xFD DATA REG1 VALUE1 REG2 VALUE2 REG42 VALUE42 REGx number of the register to modify 2 octets LSB First VALUEx value of the register to modify 4 octets LSB First Anwser ACK S...

Страница 16: ...he behavior of the RTU module Command Downlink SOF LENGTH CMD OPTIONS DATA LENGTH length bytes to follow in bytes always 8 for SIGFOX CMD Command 0x00 OPTIONS SIGFOX OPTIONS RXWIN Freq RSSI o RXWIN fenêtre de réception durant laquelle les données ont été reçues 0x00 RX1 o Freq fréquence exprimée en Hz 4 octets LSB First o RSSI niveau de réception de la trame de downlink 1 octet signé DATA downlink...

Страница 17: ...ission power in dBm 1 octet o TXTIMEONAIR transmission time of the frame expressed in ms 2 octets LSB First o SEQ Sequence number 2 octets LSB First o ULNUM Up Link Number 1 byte 1 First date UL 2 Second date UL 3 third date UL 0 OOB UL Command Power Fail Sent in the event of a power failure the supply voltage is lower than the minimum voltage AT register S260 once the command has been sent the mo...

Страница 18: ...Page 18 25 Command Init Done This command is issued as soon as the module is initialized SOF LENGTH CMD LENGTH 0x01 CMD Command 0xFE ...

Страница 19: ...plication Commands Indication command 0x00 Downlink message Sigfox No No 0x01 Trace message Sigfox No No 0x02 Uplink configuration message Sigfox No No 0x03 Power fail message Sigfox No No 0x05 Reception window opening Sigfox No No 0x07 New Cycle Allowed Sigfox No No 0x08 0xFC RFU 0xFE Init Done Sigfox No No 0xFF RFU 1 2 3 Command execution time of RTU module This chapter is only for APPLICATION m...

Страница 20: ... its UART and returns to standby mode after the processing 2 1 3 Command mode Command mode is the configuration and test command state of the RTU module Command mode may be entered from Idle mode or Nominal mode by sending the Enter Command Mode command command code 0xFE In this mode the RTU is not standby so there is no power saving while the module stays in this state The command format is based...

Страница 21: ... format ATT14 CR Command answer O CR LF for OK if command succeeds E CR LF for error if command is rejected This test is exited on reception of an ESC char on UART The module response is O CR LF on ESC reception 2 2 1 3 RF reception command This command places the RF in reception mode Command format ATT24 CR Command answer O CR LF for OK if command succeeds E CR LF for error if command is rejected...

Страница 22: ...1 CMD 0x00 2 3 1 2 Start command Allows to start up RTU module if power supply level is OK SOF LENGTH CMD LENGTH 0x01 CMD 0x01 Expected answer ACK SOF 0x03 0x01 0x06 POWERFAIL 1 octet o POWERFAIL 0 POWER FAIL power supply voltage is less than minimum power supply voltage AT register 260 200 mV le module repasse de lui même en mode STOP low power o POWERFAIL 0 POWER GOOD le module passe en mode STA...

Страница 23: ... SFX_TEST_MODE_RX_PROTOCOL with full protocol with SIGFOX key send SIGFOX protocol frames with initiate downlink flag SFX_TRUE 3 SFX_TEST_MODE_RX_GFSK RX mode with known pattern with SB SF Pattern on RX_Frequency internaly comparison with received frame known pattern AA AA B2 27 1F 20 41 84 32 68 C5 BA 53 AE 79 E7 F6 DD 9B 4 SFX_TEST_MODE_RX_SENSI Do uplink downlink frame with SIGFOX key with spec...

Страница 24: ...Page 24 25 3 Annex 1 Dipole Antenna ...

Страница 25: ...Page 25 25 PCB ANTENNA Polarization Vertical Gain 0dB 2dB Realized Gain gain efficient 0dB 2dB Parametre S END OF DOCUMENT ...