1.3 Radio registers
1.3.1 LoRaWAN Network Registers
Register
Description
Encoding
Details
201
Spreading Factor (SF) by
default
Decimal
Default: 12 (EU) / 10(US915/AS923)
READ ONLY
204
Reserved
Hexadecimal Do not use
214
LORA APP-EUI (first part
– MSB)
Hexadecimal Default: 0
Key encoded on 16 characters. Each register contains a part
of the key.
Used during the JOIN phase in OTAA mode
E.g.:
APP-EUI = 0018B244 41524632
• S214 = 0018B244
• S215 = 41524632
215
LORA APP-EUI (second
part – MSB)
Hexadecimal
216
LORA APP-KEY (first
part – MSB)
Hexadecimal Default: 0
Key encoded on 32-byte characters. Each of the 4 registers
contains 8 characters.
Used during the JOIN phase in OTAA mode
E.g.:
APP-KEY = 0018B244 41524632 0018B200 00000912
• S216 = 0018B244
• S217= 41524632
• S218=0018B200
• S219= 00000912
217
LORA APP-KEY (second
part – MID MSB)
Hexadecimal
218
LORA APP-KEY (third
part – MID LSB)
Hexadecimal
219
LORA APP-KEY (fourth
part – LSB)
Hexadecimal
220
LoRaWAN Options
Hexadecimal Default: 5 (EU), 1(US915/AS923)
Bit 0: Activation of the ADR ON (1)/OFF (0)
Bit 1: Reserved
Bit 2: DUTYCYCLE ON (1)/DUTYCYCLE OFF (0)
Bits 3 & 4: Reserved
Bits 5 to 7: Reserved
CAUTION:
Deactivation of the Duty Cycle may result in a violation of the
conditions of use of the frequency band, depending on the use
of the device, thus violating the regulations in force.
In the case of disabling the Duty Cycle, liability is transferred to
the user.
221
Mode of activation
Decimal
Default: 1
Choice: (see NOTE 1 after the table)
• 0: ABP
• 1: OTAA
222
LORA NWK_SKEY (first
part – MSB)
Hexadecimal Default: 0
Parameter encoded on 16 bytes. Each of the 4 registers
contains 4 bytes.
223
LORA NWK_SKEY
(second part - MID MSB)
Hexadecimal
224
LORA NWK_SKEY (third
part - MID LSB)
Hexadecimal
225
LORA NWK_SKEY
(fourth part – LSB)
Hexadecimal
226
LORA APP_SKEY (first
part – MSB)
Hexadecimal Default: 0
Parameter encoded on 16 bytes. Each of the 4 registers
contains 4 bytes.
227
LORA APP_SKEY
(second part - MID MSB)
Hexadecimal