1.3.2 Sigfox Network Registers
Register Size
(bytes) Base Description
Default
Value
Range
(Min-
Max)
Minimum
required
Application
version
Comments
307
2
10
Sigfox
Downlink
period
1440
(24h)
0-65535 >= V2.0.0
X 1 minute
Period: 1 min to 45 days
317
1
10
Sigfox
Duty Cycle
1
0-1
V1.2.0
0: duty cycle activated
1: duty cycle deactivated
Not displayed anymore in
LoRaWAN since 2.0.0
1.4 Coherency check
A configuration coherency check is made at the time of the backup (AT&W).
Cases where backups are refused (AT&W returns "E") because considered as inconsistent:
Cases refused
Description
S340@3 &&
S343 > S341
Luminosity: low and high thresholds enabled
(Low threshold value) (> high threshold value)
S340@3 &&
S343+S344 > S341-S342
Luminosity: low and high thresholds enabled
(Low threshold value + low threshold hysteresis) > (high threshold
value – high threshold hysteresis)
S340@1 &&
S344 + S343 > 100
Luminosity: low threshold enabled
(Low threshold value + low threshold hysteresis) > 100
S340@2 &&
S342 > S341
Luminosity: high threshold enabled
(high threshold hysteresis) > (high threshold value)
2 R
ADIO PROTOCOL
Data with size greater than 1 byte will be transmitted MSB first. In LoRaWAN, frames are sent on port 1.
2.1 Status byte
All frames sent by the product contain a status byte. Its format is identical for all IoT Adeunis products.
Alarm Status Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
Frame Counter
Reserved AppFlag1
HW
Low Bat
Config
No Error
0x00 to 0x07
X
0
0
0
0
Configuration
done
X
0
0
0
1
Low bat
X
0
0
1
0
HW Error
X
0
1
0
0
AppFlag1
X
1
0
0
0
Reserved
X
0
0
0
0
The status byte provides two bits reserved for a specific use of each product (AppFlag1 and AppFlag2).
For this product:
-
AppFlag1: configuration inconsistency
o
Samples are lost in periodic data frame because the payload is not enough.
-
AppFlag2: unused