Date: 02/12/2019
Page 4 / 15
adeunis
®
Manage & optimize your assets & services
283, rue louis Néel 38920 CROLLES, France
Tél : +33 (0)4 76 92 07 77 E-mail : [email protected]
www.adeunis.com
1 R
EGISTERS
1.1 Generic registers
Register Size
(bytes) Base
Description Default
Value
Range
(Min-Max) Comments
304
2
10
PIN code
0
(deactivat
ed)
0 - 9999
PIN code used with ATPIN command.
Value 0 disables the PIN code.
306
1
10
Product
mode
0
0: PARK
1: RUN
In PARK mode, product is not using
Radio.
In RUN mode, product will
send/receive RF uplinks/downlinks.
1.2 Applicative registers
Register Size
(bytes) Base Description
Default
value
Min-Max Value
Comments
300
2
10
Keep alive
period
8640 (24h)
2 ... 65535
X 10 seconds
301
2
10
Periodic
transmission
frequency
1
0 ... 65535
Number of backups (history
logs) to be done before
sending a frame (thus
defining the sending period).
The value 0 is equivalent to
disabling the periodic mode.
308
4
16
LED activity
0x4007F
0-0xFFFFFFFF
Default: 4007F
Eco mode: 40070
Other values: reserved
320
2
10
Historization
frequency
1
1 ... 65535
Number of samplings to be
performed before saving in
the history logs
The value 1 is equivalent to
1 backup per reading
321
2
10
Sampling/
acquisition
period
1800 (1h)
0 ... 65535
X 2 seconds
322
2
10
Sensor inhibition
for presence
detection
30
(5 min)
1 ... 65535
X 10 seconds
Correspond to the wait time
before reauthorizing
presence detection.
330
1
10
Presence alarm
activation
0
(OFF)
0: not activated
1: activated
340
1
10
Alarm type for
brightness
0
(inactive)
0: Inactive
1: Low threshold
2: High threshold
3: Both thresholds
341
1
10
High threshold
value
0
0 … 100
%
342
1
10
High threshold
hysteresis
0
0 … 100
%
343
1
10
Low threshold
value
0