Adeunis RF MOTION V2 Скачать руководство пользователя страница 2

 

 

Date: 02/12/2019 

Page 2 / 15 

 

 

adeunis

®

 

Manage & optimize your assets & services 

283, rue louis Néel 38920 CROLLES, France 

Tél : +33 (0)4 76 92 07 77 E-mail : [email protected] 

www.adeunis.com 

 

N

EW DOCUMENTATION 

/

 

N

OUVELLE DOCUMENTATION

 

 

 

ENGLISH 

FRANCAIS 

USER GUIDE  

  Dedicated to a product  

  Cautions & electrical warnings  

  Declaration of conformity 

  Product functionalities and modes 

  Casing dimensions   

  Characteristics (casing and electrical) 

  LED explanations  

  Specific wiring on terminal blocks 

  Dédié à un produit  

  Recommandations et avertissements 

électriques  

  Déclaration de conformité  

  Fonctionnalités et modes du produit 

  Dimensions du boitier   

  Caractéristiques (boitier et électrique) 

  Explication des LED  

  Câblage sur bornier spécifique au 

produit 

TECHNICAL 

REFERENCE 

MANUAL 

  Dedicated to a product  

  Registers content  

  Frame explanations (uplink and 

downlink) 

  Dédié à un produit  

  Contenu des registres  

  Explication des trames (uplink et 

downlink) 

INSTALLATION 

GUIDE  

  For all adeunis® products 

  Configuration of the products 

  Installation and fixing 

  Start-up of the products 

  Opening and closing the case 

  Replace battery 

  Pour tous les produits adeunis® 

  Configuration des produits 

  Installation et fixation 

  Démarrage des produits 

  Ouvrir et fermer les boîtiers 

  Remplacer la batterie 

 

 

Содержание MOTION V2

Страница 1: ...Manage optimize your assets services 283 rue louis N el 38920 CROLLES France T l 33 0 4 76 92 07 77 E mail sales adeunis com www adeunis com MOTION V2 Technical Reference Manual 868 EU LoRaWAN Sigfox...

Страница 2: ...nts lectriques D claration de conformit Fonctionnalit s et modes du produit Dimensions du boitier Caract ristiques boitier et lectrique Explication des LED C blage sur bornier sp cifique au produit TE...

Страница 3: ...OTOCOL 8 2 1 STATUS BYTE 8 2 2 UPLINK FRAME FORMAT 9 2 2 1 Product configuration 0x10 9 2 2 2 Digital inputs configuration 0x1F 9 2 2 3 Network configuration 0x20 10 2 2 4 Keep alive frame 0x30 10 2 2...

Страница 4: ...5535 Number of backups history logs to be done before sending a frame thus defining the sending period The value 0 is equivalent to disabling the periodic mode 308 4 16 LED activity 0x4007F 0 0xFFFFFF...

Страница 5: ...pe 0 Deactivated 1 Event ON 2 Event OFF 3 Event ON OFF 381 2 10 Digital input 1 threshold 1 1 65535 Number of detections When the number of detected events becomes above this threshold an alarm is tri...

Страница 6: ...EUI 0018B244 41524632 S214 0018B244 S215 41524632 215 LORAWAN APP EUI second part MSB Hexadecimal 216 LORAWAN APP KEY first part MSB Hexadecimal Default 0 Key encoded on 32 byte characters Each of th...

Страница 7: ...ion OTAA mode uses a JOIN phase before being able to transmit on the network This mode uses the APP_ EUI S214 and S215 and APP_KEY S216 to S219 codes during this phase to create the keys for network c...

Страница 8: ...uminosity low and high thresholds enabled Low threshold value low threshold hysteresis high threshold value high threshold hysteresis S340 1 S344 S343 100 Luminosity low threshold enabled Low threshol...

Страница 9: ...code 1 0x00 Frame counter 0 Bit1 0 no LowBat 2 3 0x21C0 8640 8640 x 10s 86400s 24h 4 5 0x0001 1 6 7 0x0001 1 8 9 0x0708 1800 1800 x 2s 3600s 1h 10 11 0x001E 30 30 x 10s 300s 5min 2 2 2 Digital inputs...

Страница 10: ...g mode 0 ABP 1 OTAA Decoding example Offset in byte Data Description 0 0x20 Frame code 1 0x20 Frame counter 1 Bit1 0 no LowBat 2 0x05 Duty cycle activated ADR ON 3 0x01 OTAA 2 2 3 1 Sigfox 868 Offset...

Страница 11: ...6 7 Presence luminosity t 2 Measured at t 2 Decoding example Offset in byte Data Description 0 0x5C Frame code 1 0x80 Frame counter 4 Bit1 0 LowBat not detected 2 0x01 A presence is currently detected...

Страница 12: ...50 2 2 8 Digital input alarm 0x51 0x52 This frame is sent when the number of detected events exceed the threshold Offset in byte Data Description 0 0x51 0x52 Frame code for digital input 1 button Fra...

Страница 13: ...F 255 considering that value 2 is a 1 byte register 5 8 0x00000000 0 considering that value 3 is a 4 byte register 2 2 10 Response to Set register request 0x33 Following reception of a downlink frame...

Страница 14: ...uct start up Exit configuration mode AT command Reception of frame 0x02 get network config 0x30 Keep alive Periodically if no periodical data is defined 0x5C Periodic data Periodically 0x5D Presence a...

Страница 15: ...F In SFX ignored by product 2 3 2 Set registers 0x41 This frame 0x41 allows you to change the value of requested S3XX registers Offset in byte Data Description 0 0x41 Frame code 1 CONFID1 Index of the...