Adeunis RF LoRaWAN Demonstrator Скачать руководство пользователя страница 7

LoRaWAN Demonstrator  (Provider) - User guide version V1.2   

 

 

 

page : 7 / 24 

 

 

Recommendations regarding use 

x

 

Before using the system, check that the power supply voltage shown in the user manual corresponds to your supply. If it 

doesn’t, please consult your supplier.

 

x

 

Place the device against a flat, firm and stable surface. 

x

 

The device must be installed in a location that is sufficiently ventilated so that there is no risk of internal heating and it must not 
be covered with objects such as newspapers, cloths, curtains, etc. 

x

 

The 

device’s aerial must be free and at least 10 cm away from any conducting material.

 

x

 

The device must never be exposed to heat sources such as heating equipment. 

x

 

Do not place the device close to objects with naked flames such as lit candles, blowtorches, etc. 

x

 

The device must not be exposed to aggressive chemical agents or solvents likely to damage the plastic or corrode the metal parts. 

x

 

Install your device close to its DC power supply. 

Disposal of waste by users in private households within the European Union 

This symbol on the product or on its packaging indicates that this product must not be disposed off with your other 
household waste. Instead, it is your responsibility to dispose of your waste by taking it to a collection point 
designated for the recycling of electrical and electronic appliances. Separate collection and recycling of your waste 
at the time of disposal will contribute to conserving natural resources and guarantee recycling that respects the 

environment and human health. For further information concerning your nearest recycling centre, please contact your 
nearest local authority/town hall offices, your household waste collection company or the shop where you bought the 
product. 

Содержание LoRaWAN Demonstrator

Страница 1: ...Demonstrator By Adeunis RF Provider Edition User guide version V1 2 Software version V1 1 ADEUNIS RF 283 rue Louis N el Parc Technologique Pr Roux 38920 CROLLES France Tel 33 0 4 76 92 07 77 Fax 33 0...

Страница 2: ...formation contained herein Reproduction use or disclosure to third parties without express permission is strictly prohibited Copyright 2012 Adeunis RF Adeunis RF is a registered trademark in the EU an...

Страница 3: ...ich this declaration refers conform with the relevant standards or other standardising documents x EN 300 220 1 v2 4 1 2012 05 x EN 60950 1 2001 A11 2004 x EN 301 489 1 v1 8 1 2008 04 x EN 301 489 3 v...

Страница 4: ...chen Union 9 2 DEVICE OVERVIEW 10 2 1 Form factor 10 2 2 Technical specifications 10 3 CHARGING THE DEMONSTRATOR 11 4 USING THE DEMONSTRATOR 12 4 1 LoRa testing mode 12 4 2 User mode 13 5 DEVICE CONFI...

Страница 5: ...ion V1 2 page 5 24 Figure 1 Demonstrator physical description 10 Figure 2 Product during charge 11 Figure 3 Product when charge is completed 11 Figure 4 using the device 12 Figure 5 Device as a serial...

Страница 6: ...rams are the exclusive property of ADEUNIS RF Any transfer granting of licences to a third party leasing hire transport copying editing translation modification into another programming language or re...

Страница 7: ...orches etc x The device must not be exposed to aggressive chemical agents or solvents likely to damage the plastic or corrode the metal parts x Install your device close to its DC power supply Disposa...

Страница 8: ...erden k nnten Die Bezeichnungen der Programme sowie alle Urheberrechte zu den Programmen sind das alleinige Eigentum der ADEUNIS RF Jede bertragung Gew hrung von Lizenzen an einen Dritten Leasingverga...

Страница 9: ...ls der Einwirkung von aggressiven Chemikalien oder L semittel ausgesetzt werden die geeignet sein k nnten den Kunststoff zu besch digen oder die Metallteile zu korrodieren x Stellen Sie Ihr Ger t in d...

Страница 10: ...ensor Figure 1 Demonstrator physical description 2 2 Technical specifications Technical specifications Communication LoRaWAN protocol LoRa Modulation Module configuration Through AT commands Radio dat...

Страница 11: ...ch is on the OFF position this behavior is similar to the one of mobile phones The product can still be used while it s charging During the charging process the charge state indicator is steady red Wh...

Страница 12: ...is reserved to the ROOT level of authorization This level can be reached by using the command ATT63 ROOT Refer to chapter 5 2 for details of the command The device must be place in command mode using...

Страница 13: ...hase description LED1 LED2 Startup In personalization mode the device checks if a device address is present In OTAA mode the devices waits for the network to provide the necessary keys Steady Red Gree...

Страница 14: ...will be recognized as a serial peripheral creation of a virtual serial COM port 5 1 Serial link parameters Parameter Value Speed 115200 bps Parity None Bits 8 Stop bit 1 When plugged to a PC the devi...

Страница 15: ...the command is rejected x Ends by CR LF The following commands are available Command Description Reply example FF FF FF FF Entry in command mode CM cr lf AT V Displays the firmware version LORA DEMO...

Страница 16: ...the air activation OTAA In either case the DEV EUI which is essentially a MAC address is provided by the end point manufacturer in this case ADEUNIS 5 3 1 1 Personalization mode In personalization mod...

Страница 17: ...NWK_SKEY MID MSB 0 224 LORA NWK_SKEY MID LSB 0 225 LORA NWK_SKEY LSB 0 226 LORA APP_SKEY MSB 0 227 LORA APP_SKEY MID MSB 0 228 LORA APP_SKEY MID LSB 0 229 LORA APP_SKEY LSB 0 281 Device Address 0 5 3...

Страница 18: ...transmitted by the network during OTAA the CF list values will prevail By default channels 0 2 use the LoRaWAN parameters and channels 3 6 are deactivated If a register contains other values than 0 o...

Страница 19: ...register S201 see 5 3 7 Note on ADRACKReq When the device has transmitted multiple frames but hasn t received any downlink whether it s a generic downlink or an ACQ from the server enabling ADRACKReq...

Страница 20: ...meter The device s accelerometer is configured by default to trigger whenever the device is shaken by hand However its configuration can be modified to suit the user s application Two parameters can b...

Страница 21: ...s stationary or walking pace with good satellite visibility Note 1 As periodic mode is less powerful we highly recommend a startup time 5min so that the GPS can synchronize and acquire the ephemeris a...

Страница 22: ...al part of Latitude s minutes tenths of minutes b 3 0 BCD coding of the decimal part of Latitude s minutes hundredths of minutes 6 b 7 4 BCD coding of the decimal part of Latitude s minutes thousandth...

Страница 23: ...act a negative number as the RSSI will saturate above 20dBm For example if the value is 100 this means that the RSSI is 100 dBm x The SNR value is a signed value in two s complement ranging from 128 t...

Отзывы: