Adeunis RF LoRaWAN 915 FTD Скачать руководство пользователя страница 1

 LoRaWAN 915 FTD – User guide version 1.0 

   

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

LoRaWAN 915 Field Test Device 

By Adeunis RF 

PROVIDER Edition 

 

User Guide Version 1.0 

 
 

 

 
 

 

Document revision 

Version 

Date 

Author 

Comment 

 

 

YRM 

 

 

 

YRM 

 

1.0 

05/10/2016 

YRM 

Initial release 

 
 
 

ADEUNIS RF 

283 rue Louis Néel - Parc Technologique Pré Roux 38920 CROLLES - France 

Tel. : +33 (0)4 76 92 07 77 - Fax : +33 (0)4 76 04 80 87 

www.adeunis-rf.com

   

[email protected]

 

Содержание LoRaWAN 915 FTD

Страница 1: ...IDER Edition User Guide Version 1 0 Document revision Version Date Author Comment YRM YRM 1 0 05 10 2016 YRM Initial release ADEUNIS RF 283 rue Louis N el Parc Technologique Pr Roux 38920 CROLLES Fran...

Страница 2: ...formation Title LoRaWAN 915 Field Test Device by Adeunis RF Subtitle User Guide Version 1 0 Document type User Guide Document status Beta This document applies to the following products Name Reference...

Страница 3: ...THE FTD 13 2 DEVICE OPERATION 14 2 1 USER INTERFACE 14 2 1 1 Button 1 14 2 1 2 Button 2 14 2 1 3 ON OFF button 14 2 1 4 Charge State Indicator 14 2 1 5 USB connector 14 2 1 6 LCD screen description 1...

Страница 4: ...33 ANNEX 3 BAND TYPES 34 Figure 1 Product during charge 13 Figure 2 Product when charge is completed 13 Figure 3 Front view 14 Figure 4 Bottom view 14 Figure 5 Main Screen 15 Figure 6 GPS screen 16 Fi...

Страница 5: ...electrical mechanical magnetic or optical devices manually or any by other methods is prohibited ADEUNIS RF reserves the right to change the technical specifications or functions of its products or to...

Страница 6: ...the provided documents contact our Technical Support by email Use our dedicated email address arf adeunis rf com rather than any personal email address of our staff This makes sure that your request i...

Страница 7: ...ation refers conform with the relevant standards or other standardising documents EN 300 220 1 v2 4 1 2012 EN 60950 1 2006 A1 2010 A2 2013 A11 2009 A12 2011 EN 301 489 1 v1 9 2 2011 EN 301 489 3 v1 6...

Страница 8: ...lete equipment are disposed of Warnings Valid for the following product ARF8123AA Read the instructions in the manual The safety of this product is only guaranteed when it is used in accordance with i...

Страница 9: ...lose to its DC power supply Disposal of waste by users in private households within the European Union This symbol on the product or on its packaging indicates that this product must not be disposed o...

Страница 10: ...zeichnungen der Programme sowie alle Urheberrechte zu den Programmen sind das alleinige Eigentum der ADEUNIS RF Jede bertragung Gew hrung von Lizenzen an einen Dritten Leasingvergabe Vermietung bereig...

Страница 11: ...rgung der Abf lle von Betreibern in Privathaushalten innerhalb der Europ ischen Union Dieses Symbol auf dem Produkt oder auf seiner Verpackung weist darauf hin dass dieses Produkt nicht gemeinsam mit...

Страница 12: ...ocol It allows transmitting receiving and instantly viewing the radio frames on the used network Equipped with a large LCD screen you can check all operating information GPS coordinates temperature ba...

Страница 13: ...B 5V 500mA Standard compliance FCC part 15 247 1 4 Charging the FTD The product contains a rechargeable battery Upon connecting it to a computer via a micro USB cable it will automatically begin charg...

Страница 14: ...push activates LCD backlight 2 If LCD backlight is already activated pushing BTN2 changes the LCD display 2 1 3 ON OFF button The ON OFF button turns the device ON or OFF Slide the button to the right...

Страница 15: ...is deactivated GPS is not synchronized GPS is synchronized RF status No Icon Product is Idle Device is trying to Join a network Manual transmission has been triggered Periodic transmission has been t...

Страница 16: ...accuracy 2 bars medium accuracy 3 bars good accuracy The rest of the screen indicates the Latitude and Longitude If the GPS isn t synchronized the LAT and LON fields are left blank and a satellite di...

Страница 17: ...LCD screen Power OFF the device by sliding the ON OFF switch to the left This should power OFF the LCD screen 2 2 3 Join procedure If the device is in OTAA mode it will automatically execute a Join p...

Страница 18: ...e recognized as a serial peripheral creation of a virtual serial COM port 3 1 Serial link parameters Parameter Value Speed 115200 bps Parity None Bits 8 Stop bit 1 When plugged to a PC the device shou...

Страница 19: ...nds by CR LF The following commands are available Command Description Reply example FF FF FF FF Entry in command mode CM cr lf AT V Displays the firmware version LORA DEMO _v1 0 cr lf ATS n Returns co...

Страница 20: ...he DEV EUI which is essentially a MAC address is provided by the end point manufacturer in this case ADEUNIS 3 3 1 1 Activation by Personalization mode ABP In personalization mode the user has to manu...

Страница 21: ...P KEY MID MSB 0 218 LORA APP KEY MID LSB 0 219 LORA APP KEY LSB 0 222 LORA NWK_SKEY MSB 0 223 LORA NWK_SKEY MID MSB 0 224 LORA NWK_SKEY MID LSB 0 225 LORA NWK_SKEY LSB 0 226 LORA APP_SKEY MSB 0 227 LO...

Страница 22: ...e default configuration Other User defined will be taken into account ONLY IF THERE IS NO CF LIST If the device is configured in OTAA and a CF list is transmitted by the network during OTAA the CF lis...

Страница 23: ...nel First channel of the channel list It can take value from range 0x00 to 0xFF 0 255 C0 902 000 MHz Cn C0 n 0 1 MHz with 0 n 256 n must be expressed in hexadecimal in register 250 to 256 C255 902 000...

Страница 24: ...f step width 4hex means DRmax 4 4hex means DRmin 4 3 Set 8 downlink channels from 923 3 MHz to 927 5 MHz spaced by 600 kHz with data rate range from DR8 to DR13 Bandwidth 500 kHz the user should type...

Страница 25: ...ription Frequency Frequency can take value from range 0x9020 to 0x9279 expressed in BCD Values 0x000A to 0x000F are forbidden DR Data rate range is managed by LoRa stack User can define uplink min dat...

Страница 26: ...l be taken into account ONLY IF THERE IS NO CF LIST If the device is configured in OTAA and a CF list is transmitted by the network during OTAA the CF list values will prevail By default RX2 contains...

Страница 27: ...config disable Manual Stack 4 3 only NA if stack 4 1 8 0 0 Join Auto repetition disable 1 Join Auto repetition enable Stack 4 3 only NA if stack 4 1 Note on ADR If ADR is activated the device will hav...

Страница 28: ...llowing register Register Number Description Default Value Range Values Comment 380 Frame TX periodicity 20 0 86400 In seconds If the register is set to 0 periodic transmission is disabled Frames can...

Страница 29: ...rator If desired the payload format can be changed to add new information to it This can be done through register 370 Register Number Description Default Value Range Min Max Comment 370 Payload format...

Страница 30: ...hemisphere 0 North 1 south 6 b 7 4 BCD coding of the integer part of Longitude s degrees hundreds of degrees b 3 0 BCD coding of the integer part of Longitude s degrees tens of degrees 7 b 7 4 BCD cod...

Страница 31: ...Counter is present Bit 1 1 Battery voltage information is present Bit 0 RSSI SNR information is present 2 Temperature in C signed in two s complement 3 Uplink frame counter 4 Downlink frame counter 5...

Страница 32: ...LoRaWAN 915 FTD User guide version 1 0 Page 32 35 ANNEX 1 LoRa Cycle The following diagram shows a simplified description of a LoRa cycle...

Страница 33: ...lute value in dB It is in fact a negative number Example if the value is 100 this means that the RSSI is 100 dBm SNR The SNR value is a signed value in two s complement ranging from 128 to 127 Values...

Страница 34: ...g DR value Description 0 Uplink SF10 125 kHz 1 Uplink SF9 125 kHz 2 Uplink SF8 125 kHz 3 Uplink SF7 125 kHz 4 Uplink SF8 500 kHz 5 RFU 6 RFU 7 RFU 8 Downlink SF12 500 kHz 9 Downlink SF11 500 kHz 10 Do...

Страница 35: ...LoRaWAN 915 FTD User guide version 1 0 Page 35 35 END OF DOCUMENT...