Ref. 08-07-V5-lmn
p. 5
A
RF44
User Guide
Signal description
Pin
number
Pin name
I/O direction
Description
Power and reset
1, 17, 18
GND
Digital GND (connected with
radio GND)
2
VCC
Power supply
3
/Reset
Reset
RF interface
20
GND RF
Radio GND (connected with
digital GND)
22
RF in/out
RF Antenna IN/OUT
24
GND RF
Masse radio (connected with
digital GND)
Serial interface
14
RxD
I
Serial input.
16
TxD
O
Serial output
Powerdown
4
Power-down
I
Powerdown mode management
(leave unconnected if not used)
Not used
5, 6, 7, 8, 9, 10,
11, 12, 13, 15
Reserved
O
Directions are noted from module point of view.
Radio Communication
Available Channels
This module modem has 14 channels over the 863-870 MHz Band that can
be selected using AT commands.
The channels are selected according to the following table: