Chapter 4: System Installation
Installing AC Power Cable to Robot
1. Connect the AC power cable to your facility AC power source. See Figure 4-4 and Figure
4-5. Do not turn on AC power at this time.
2. Plug the AC connector into the AC power connector on the interface panel on the robot.
3. Secure the AC connector with the locking latch.
4.10 Grounding the Adept Quattro Robot System
Proper grounding is essential for safe and reliable robot operation.
NOTE:
You must ground the robot to the frame for all installations.
Adept Quattro Robot Base
One of the base mounting pads has two small holes (in addition to the M16 mounting hole).
One of these is an M8 hole, provided as a protective earth ground.
Alignment Hole
Mounting Hole
Ground Hole
Robot
Figure 4-7. Base Mounting Pad with Ground Hole, Top View
Quattro HS Robot Base
Because of the need to seal the junction between the robot base and the frame, the protective
earth ground connection for the HS robots has been moved from the base mounting pad to
inside the AIB cable inlet box, which is electrically connected to the robot base.
The ground screw is marked inside the cable inlet box with a label.
Robot-Mounted Equipment
DANGER:
Failing to ground robot-mounted equipment
or tooling that uses hazardous voltages could lead to
Adept Quattro User's Guide, Rev E
Page 80 of 180
Содержание Quattro s650H
Страница 1: ...Adept Quattro User s Guide covers the Adept Quattro s650H s650HS s800H and s800HS Robots...
Страница 2: ......
Страница 82: ......
Страница 102: ......
Страница 108: ......
Страница 164: ......
Страница 174: ......
Страница 178: ......
Страница 179: ......
Страница 180: ...P N 09955 000 Rev E 5960 Inglewood Drive Pleasanton CA 94588 925 245 3400...