Chapter 3: Robot Installation - HS
supplied 24 VDC cable. See the following figure.
Figure 3-11. Cable Shield Ground Lug Attachment
3. Hand-tighten all cables to the AIB.
NOTE:
All cables must be screwed into the AIB.
The protective earth ground will be installed in the following section.
Installing the Cable Inlet Box
1. Install the cable inlet box on the top of the AIB using three M4 x 40 bolts.
l
Ensure that the gasket is seated between the AIB surface and the cable inlet box.
l
Do not yet use the hole labeled as a ground.
l
Apply Loctite 222 in these bolt holes, not on the bolts themselves.
l
Torque the bolts to 1.1 N·m (10 in-lb).
NOTE:
The cable inlet box should be installed with the cables exiting away from
the AIB. The cable tray attachment was designed assuming the cables would exit
away from the AIB.