Installation on an Adept Cobra s350 System
Adept IO Blox User’s Guide, Rev B
15
2.4
Installation on an Adept Cobra s350 System
Mechanical Mounting
For Adept Cobra s350 robots, the IO Blox can be mounted on a DIN rail - see
.
Cable Installation
1. Locate the IO Blox-to-Robot cable supplied with the system.
2. Connect the end of the cable with the matching D-sub connector to the EXPIO
connector on the MB-40R.
Figure 2-6. IO Blox Cable Connection to Cobra s350 Robot System
3. Connect the other end of the cable to the JCBL1 connector on the IO Blox. See
for the location of JCBL1.
NOTE:
To install multiple IO Blox devices, see
.
MB-40R
IO Blox Device
To EXPIO
on MB-40R
Adept Cobra s350 System
(robot not shown)