Chapter 6 - Optional Equipment Installation
78
Adept Cobra s800 Inverted Robot User’s Guide, Rev C
NOTE:
The cover on the outer link must be removed for maintenance
(lubrication), so keep this in mind when mounting any external
equipment to the outer link cover.
Also see
for information on mounting cameras on the robot.
6.6
Installing Robot Solenoid Kit
Introduction
This procedure describes how to mount the 24 V solenoid option kit on an Adept Cobra
s800 Inverted robot. The solenoid kit is available as Adept p/n 02853-000.
The robot has been prewired to accommodate a bank of two 24 VDC solenoid valves.
Power for the internal mounting is accessible via a connector mounted inside the outer
link cover (see
). The signals actuating the valves are directly
switchable from V
+
utilizing software signals 3001 and 3002. Refer to the SIGNAL
command in the
for additional information. The
Adept-supplied solenoids each draw a nominal 75 mA from 24 VDC.
The solenoid valve assembly consists of two independent valves (Valve #1 and Valve #2)
on a common manifold. The manifold supplies air at the user’s line pressure (28 psi
minimum (0.19 MPa) to 114 psi (0.786 MPa) maximum). Each valve has two output ports,
A and B. The output ports are arranged so that when Port A is pressurized, Port B is not
pressurized. Conversely, when Port B is pressurized, Port A is not. In the Adept Cobra
s-series robots, the air lines from Port A on each valve are plugged at the factory (at the
solenoid assembly).
The Solenoid Kit for the Adept Cobra s-series robot is available through Adept. Contact
your Adept Sales Representative for current price and availability.
Tools Required
• Assorted Allen drivers
• Tie-wraps
• Diagonal wire cutters
• Solenoid Valve Upgrade Kit (Adept p/n 02853-000)
Procedure
1. Turn off all power to the robot.
Table 6-6. Air Pressure
Air Pressure (Psi)
Air Pressure (MPa)
28 - 114
0.19 - 0.786
Содержание Cobra s800
Страница 1: ...Adept Cobra s800 Inverted Robot User s Guide...
Страница 2: ......
Страница 14: ......
Страница 42: ......
Страница 68: ......
Страница 94: ......
Страница 112: ......
Страница 136: ......
Страница 150: ......
Страница 155: ......
Страница 156: ...3011 Triad Drive Livermore CA 94551 925 245 3400 P N 06937 000 Rev C...