Chapter 4 - System Installation
48
Adept Cobra s600/s800 Robot User’s Guide, Rev H
AC Power Diagrams
Figure 4-3. Typical AC Power Installation with Single-Phase Supply
Figure 4-4. Single-Phase AC Power Installation from a Three-Phase AC Supply
Details for AC Mating Connector
The AC mating connector is supplied with each system. It is typically shipped in the
cable/accessories box. The supplied plug is internally labeled for the AC power
connections (L, E, N).
NOTE:
The AC power cable is not supplied with the system, but is
available in the optional Power Cable kit; see
Table 4-7. AC Mating Connector Details
AC Connector details
AC in-line power plug,
straight, female, screw
terminal, 10 A, 250 VAC
Qualtek P/N 709-00/00
Digi-Key P/N Q217-ND
E
E
N
N
L
L
F1 10A
Adept Co
b
ra
s600/s800 and
i600/i800 Ro
b
ots
1Ø 200–240VAC
User-S
u
pplied
AC Power Ca
b
le
Note: F1 is
u
ser-s
u
pplied, m
u
st
b
e slow
b
low.
1Ø
200–240VAC
20A
L = Line
N = Ne
u
tral
E = Earth Gro
u
nd
E
E
N
L3
L
L1
L2
F5 10A
F4 10A
Adept Co
b
ra
s600/s800 and
i600/i800Ro
b
ots
1Ø 200–240VAC
User-S
u
pplied
AC Power Ca
b
le
Note: F4 and F5 are
u
ser-s
u
pplied, m
u
st
b
e slow
b
low.
3Ø
200–240VAC
L = Line 1
N = Line 2
E = Earth Gro
u
nd
200–240VAC
Содержание Cobra s600
Страница 1: ...Adept Cobra s600 s800 Robot User s Guide...
Страница 2: ......
Страница 14: ......
Страница 20: ......
Страница 52: ......
Страница 68: ......
Страница 80: ......
Страница 116: ......
Страница 132: ......
Страница 146: ......
Страница 151: ......
Страница 152: ...5960 Inglewood Drive Pleasanton CA 94588 925 245 3400 P N 03017 000 Rev H...