INTRODUCTION

Thank you for purchasing this MAC-AFRIC compressor which is designed to 
supply compressed air to air powered tools.

IMPORTANT FACTORS TO CONSIDER WHEN CHOOSING 

THE CORRECT SIZE COMPRESSOR

• 

CFM

 (cubic feet per minute) requirement: probably the single biggest consideration when 

choosing the correct compressor. What CFM will your air compressor need to produce in 
order to supply sufficient air flow at the required pressure for the air tool operation?

• 

RULE OF THUMB

 – always multiply your air tool CFM rating by 1.2 in order to choose the 

appropriate size compressor. 

• 

TANK SIZE – 

choosing the correct size tank is very important! With the range of sizes 

available from 6 litres up to 500 litres it is vitally important that the correct size is chosen 
for the intended application.

• 

Professional, semi-professional or D.I.Y use –

 all compressors comes with specific 

warranties to cover DIY/home use or commercial use. Make sure that you choose the 
correct size compressor for your application.

Before attempting to use this product, please read this manual thoroughly and follow the instructions carefully. 
In doing so you will ensure the safe operation of the compressor.

SAFETY PRECAUTIONS

Before using your compressor it is in your own interest to read and pay attention 
to the following safety rules:

I. 

COMPRESSED AIR IS DANGEROUS- Never direct a jet of air at people or animals.

II. 

Do not operate your air compressor with any guards removed.

III. 

Electrical or mechanical repairs should only be carried out by a qualified electrician/
engineer. If you have a problem, please contact your nearest Adendorff branch or 
alternatively our Head-Office service department on (011) 434 7000 or 0861 233636

IV. 

Before attempting any repair ensure pressure is expelled from the air receiver and 
disconnected from the electricity supply.

V. 

Do not leave pressure in the air receiver overnight or when transporting.

VI. 

Do not adjust or tamper with any safety valves. The maximum working pressure of the 
compressor is clearly stated on the machine.

VII. 

Exercise caution when transporting the machine to avoid tipping the machine over.

VIII. 

Do not operate in a wet/damp environment. 

IX. 

Locate your air compressor on a firm flat surface with AVPs and ensure an adequate supply 
of clean air is available for the pump unit.

X. 

Do not exert any strain on electrical cables and ensure that air hoses are not tangled or 
wrapped around machinery etc.

XI. 

The cylinder head and delivery pipes of your compressor become quite hot during operation. Do 
not touch. After switching off remember to leave an adequate cool-down period before touching. 

XII. 

Ensure that any equipment/tool used in conjunction with your compressor has a safe 
working pressure exceeding the output pressure set on the machine.

XIII. 

When disconnecting air hoses or other equipment from your compressor ensure that the air 
supply is turned off at the machine outlet and expel all pressurised air from within the air 
hose and other equipment attached to it. 

XIV. 

If using your compressor for paint spraying:

 

i)  

never spray close to any source of flame or heat.

 

ii)  

always ensure that the spraying area has adequate fresh air ventilation.

 

iii) 

Hazardous paints require special apparatus (see paint manufacturers   

  

recommendations).

XV. 

Never let anyone operate the compressor unless they have had the necessary training. 

XVI. 

Permanently installed pipework systems should be designed and installed by a competent 
engineer.

MODELS 
COVERED:

ELECTRICAL 

MODELS

DIRECT DRIVE

COMPRE-024
COMPRE-515
COMPRE-115
COMPRV-123

BELT DRIVEN

COMPRE-517 
COMPRV-120
COMPRE-210
COMPRE-300
COMPRE-315
COMPRE-615
COMPRV-130
COMPRV-230
COMPRV-355
COMPRV-375
COMPRV-377
COMPRV-510
COMPRV-575

COMPRE-310
(VERTICAL)

PETROL 

MODELS

COMPRE-070
COMPRE-071
COMPRE-705

Содержание MAC-AFRIC COMPRE-024

Страница 1: ...GINAL OPERATING INSTRUCTIONS 2018 Model M1H ZP2 1 250 I WSAWLD 004 ORIGINAL OPERATING INSTRUCTIONS Adendorff machinery mart ELECTRICAL DIRECT BELT DRIVEN PETROL DRIVEN DANGER Read all safety regulatio...

Страница 2: ...ure is expelled from the air receiver and disconnected from the electricity supply V Do not leave pressure in the air receiver overnight or when transporting VI Do not adjust or tamper with any safety...

Страница 3: ...used contrary to their instruction manuals and on batteries Under this warranty we do not have the obligation To bear any transportation fees of any product to from the Warranty centre Any incidental...

Страница 4: ...ironment III Adequate ventilation for i Air intake to compressor pump in order to draw in clean air ii Cooling to compressor pump and electric motor IV To allow sufficient access for servicing a minim...

Страница 5: ...are almost always cheaper than electric tools when comparing life span Air tools have considerably lower maintenance requirements meaning less downtime SAFER THAN ELECTRICITY Air tools are safer simpl...

Страница 6: ...Electric Motor 14b Pressure Gauge 4 Oil Level Sight Glass 11 Wire Guard 14c Saftey Valve 5 Air Delivery Pipe 12 Saddle 14d Air Bleed Valve 6 Air Compressor Pump 13 Air Bleed Pipe 14e Air Bleed Pipe 7...

Страница 7: ...s is available from your local Adendorff Branch OVERLOAD BUTTON SINGLE PHASE ONLY only applicable to certAIN MODELS The electric motor is fitted with an automatic overload detector which will stop the...

Страница 8: ...4 0 5 5 25 amp 5 5 7 5 30 amp 7 5 10 0 35 amp 25 amp 2 11 7 6 12a 12b 12c 12d 12f 12g 12e 4 5 10 3 1 Illustrative purposes only 12 9 8 GENERAL ARRANGEMENT DIRECT DRIVE MODEL I Inspection Plug 8 Air D...

Страница 9: ...CORDS this will in turn cause a voltage drop thus causing the electrical motor to labour and the windings on the motor will burn out IMPORTANT TIP rather plug the compressor at the wall plug on a sep...

Страница 10: ...starts but stops again after only a few revolutions Non return valve leaking compressor unit is on load during start Disconnect from the mains supply and empty air receiver Clean or replace Non Retur...

Страница 11: ...tion of connected equipment Install a larger compressor Compressor worn Have compressor overhauled or replace it Compressor becomes too hot Insufficient ventilation See that sufficient air is supplied...

Страница 12: ...Safety Valve 5 Air Filter Motor 12 Air Compressor Pump 17 Oil Level Sight Glass 6 Petrol Motor 13 Air Intake Filter 18 Oil Drain Plug 7 Pull Start Recoil 19 Drain Tap Note Illustrations are for refere...

Страница 13: ...area is well ventilated GENERAL SAFETY RULES WARNING EXHAUST FUMES CAN BE EXTREMELY DANGEROUS IF INHALED WORK AREA Always use in a well ventilated area Always position the exhaust outlet away from pe...

Страница 14: ...plastic covers as shown CHECKING THE ENGINE OIL LEVEL WARNING TO CARRY OUT THIS CHECK PLACE THE COMPRESSOR ON LEVEL GROUND WITH THE ENGINE SWITCHED OFF WARNING TAKE CARE NOT TO TOUCH ANY HOT PARTS OF...

Страница 15: ...cap securely USING THE COMPRESSOR STARTING THE ENGINE 1 Set the fuel valve to the ON position 2 Move the choke lever to the choke position 3 Ensure that the Engine Switch is on and the air release val...

Страница 16: ...R POUR IT DOWN DRAIN OR SINKS PLACE IT IN A LEAK PROOF CONTAINER AND TAKE IT TO YOUR LOCAL WASTE DISPOSAL SITE CHANGING THE SPARK PLUG CAUTION ALLOW THE ENGINE TO COOL BEFORE REMMOVING THE SPARK PLUG...

Страница 17: ...PETROL TO CLEAN THE AIR FILTER 4 Replace the filter to its original position and replace the air filter cover REPLACE THE IN LINE FUEL FILTER applicable to certain models 1 Set the fuel supply to OFF...

Страница 18: ...ammer 7 10 Framing Nailer 2 5 3 Grease Gun 4 High Speed Grinder 8 12 Hoists 1 ton 1 Hydraulic Riveter 4 Hydraulic Lift 8000lb 6 Air Tool Equipment cfm Average Free Air Consumption Hydraulic Floor Jack...

Страница 19: ...uct s complies with the following directive s The Simple Pressure Vessels SPV 2014 29 EU EN286 1 1998 A1 2002 Notified Body APRAGAZ Identification number 0029 156 Chaussee De Vilvorde B 1120 Bruxelles...

Отзывы: