LYNXR is not intended for UL985 Household Fire applications.

Introduction

This Quick Start Guide can help you install the rechargeable LYNXR and LYNXR24 quickly and easily by providing
the basic steps for installation using the built-in defaults.  For more detailed information and important notes, refer
to the LYNXR/LYNXR24 Installation Instructions.

The following steps assume that one of the system’s default tables will be used.
For programming data values and Powerline Carrier Devices other than those listed in the default tables, see the
Installation Instructions.

Default Table Summary

Zone

Table 1

Table 2

Table 3

Table 4

1

-------

-------

-------

-------

2

front door

front door

front door

front door

3

back door

back door

back door

back door

4

window

Garage door

window

window

5

motion detector

motion detector

window

window

6

-------

smoke detector

window

window

7

-------

-------

window

window

8

-------

-------

motion detector

motion detector

9

-------

-------

smoke detector

smoke detector

26

loop 3 arm away

loop 3 arm away

loop 3 arm away

loop 3 arm away

27

loop 2 disarm

loop 2 disarm

loop 2 disarm

loop 2 disarm

28

loop 4 arm stay

loop 4 arm stay

loop 4 close device

loop 4 close device

29

loop 1 restore device 1

loop 1 restore device 1

loop 1 restore device 1

loop 1 restore device 1

30

loop 3 arm away

loop 3 arm away

loop 3 arm away

loop 3 arm away

31

loop 2 disarm

loop 2 disarm

loop 2 disarm

loop 2 disarm

32

loop 4 arm stay

loop 4 arm stay

loop 4 close device

loop 4 close device

33

loop 1 restore device 1

loop 1 restore device 1

loop 1 restore device 1

loop 1 restore device 1

92

duress

duress

duress

duress

99

silent alarm

silent alarm

silent alarm

silent alarm

User Code

1-2-3-4

1-2-3-4

1-2-3-4

1-2-3-4

Install Code

4-1-1-2

4-1-1-2

4-1-1-2

4-1-1-2

Entering Program Mode: installer code + 8 0 0

Interactive Mode

Used to Program

*56 Enhanced Zone Programming

Zone characteristics, report codes, and serial numbers

*83 Sequential Mode

5800 Series transmitter serial numbers

*84 Assign Zone Voice Descriptors

Voice descriptors for each zone

Exiting Program Mode: *99 allows re-entry into the Program mode using Installer Code + 8  0  0.

*98 inhibits re-entry into the Programming mode using the Installer Code.

NOTES:

  •

Tables 2 and 4 support the automatic paging feature (open/close events reported to pager phone number),and a Powerline
Carrier Device programmed as device 8, which closes and stays closed upon burglary alarms and restores after bell timeout. For
other applications or actions (e.g., using a pulsing siren), see the *80 Device Programming Menu Mode section of the Installation
Instructions.

Primary report format for all tables is Ademco’s Contact ID reporting. Tables 2 and 4 also use Contact ID for secondary
reporting. Tables 1, and 3 use 4+1 format for secondary reporting.

Table 2 records all events in the event log. Tables 1, 3, and 4 record only alarms, alarm restores, troubles, and trouble restores
in their event logs.

Содержание LYNXR

Страница 1: ...2 disarm loop 2 disarm loop 2 disarm 32 loop 4 arm stay loop 4 arm stay loop 4 close device loop 4 close device 33 loop 1 restore device 1 loop 1 restore device 1 loop 1 restore device 1 loop 1 restor...

Страница 2: ...mer to terminals 9 13 and 14 respectively Note Install Powerline Carrier Devices according to their instructions f Connect wires from the 1332 1332X10 1332CN AC Transformer to terminals 15 and 16 3 Ma...

Страница 3: ...D WITH THIS EQUIPMENT 1332X10 ONLY CONNECTIONS FCC ID CFS8DLLYNX COMPLIES WITH FCC RULES PART 68 FCC REGISTRATION No 5GBUSA 25623 AL E RINGER EQUIVALENCE 0 6B 1332 1332X10 1332CN CONNECTIONS NOTE USE...

Страница 4: ...a 4 button key it assumed that all loops are used and only the serial number is confirmed Pressing any key will allow a confirm Two beeps indicate that the template has been accepted A single long bee...

Страница 5: ...es Transmitter Loop Numbers The following illustration shows the compatible transmitters and their associated input types and loop designations LOOP 1 5806 5807 5808 5808LST ENROLL AS RF LOOP 1 5809 E...

Страница 6: ...FUNCTION VOLUME 3 or 6 Other Functions To set the time and date User Code FUNCTION 63 To activate or deactivate devices 1 6 FUNCTION LIGHTS ON or LIGHTS OFF device number To activate or deactivate de...

Страница 7: ...NOTES 7...

Страница 8: ...165 Eileen Way Syosset New York 11791 Copyright 2000 i l K5484 7 00...

Отзывы: