background image

 

K3703V4  3/03 

®

 

LYNX-AVM

Audio Verification Module

Installation and Setup Guide 

Introduction 

The LYNX-AVM is an audio verification module that allows 
2-way communication between a Central Station Operator 
and a person at the protected premises.  

The LYNX-AVM is compatible with the following control 
panel families: LYNX /LYNXR, VISTA-10P, VISTA-15P, 
VISTA-20P, and VISTA-20PS.   

This document provides: 

• 

an overview of audio alarm verification (AAV) 

• 

instructions for wiring to the LYNX-AVM and installing 
the battery 

• 

programming information. 

 

 

®

03000-001-V0

 

UL

 

This device is not applicable for UL Listed installations. 

How Alarm Verification Works 

The following table shows the stages of audio alarm verification. 

 

Stage 

The Control Panel… 

The LYNX-AVM… 

The Central Station… 

1  

Alarm occurs 

seizes the phone line and 
reports the alarm to the 
Central Station. 

stands by. 

Digital Receiver processes the 
alarm report. 

Listen-In To 
Follow 

ends the report with a “listen-
in to follow” message 
(Contact ID event code 
E606). 

stands by. 

Digital Receiver holds the phone 
line connection for one minute. 

Audio 
Verification 

LYNX-AVM, then gives up 
phone line. Sirens and 
keypad sounds are shut off. 
Control stands by for next 
alarm. 

 

receives “kissoff,” activates, 
and holds the phone line 
without breaking the 
connection to the Central 
Station. 

 

operator can pick up the phone 
to speak to person at protected 
premises, who in turn can reply 
using the built-in microphone in 
the LYNX-AVM. See 
Activation/Operator Commands 
section. 

End Call 

stands by for next alarm. 

hangs up the phone line. 

operator ends the conversation 
and proceeds according to 
central station procedures. 

Wiring the LYNX-AVM 

The LYNX-AVM can be wired to either a LYNX/LYNXR Security Control Panel or a VISTA-10P, VISTA-
15P, VISTA-20P, or VISTA-20PS Control Panel.  The following paragraphs provide the wiring 
instructions for each. 

Wiring to a LYNX/LYNXR Security Control Panel 

Refer to the diagram on the next page when making wiring connections from a LYNX-AVM to a 
LYNX/LYNXR Security Control Panel. 

1.  Remove the face plate of the LYNX-AVM by removing the retaining screw and separating the plate 

from the back box.

 

2.  Connect the flying leads of the RJ-12 cable (supplied) to the LYNX/LYNXR Security Control Panel 

terminals as shown below. 

3.  Route the cable through the hole in the base of the LYNX-AVM.