background image

 

 

 

CFV15P/CFV15PCN 

 

 

 

 

 

Programming Guide

 

 

 
 
 
 
 
 

 

ON

OFF

1

OFF

4

MAX

7

INSTANT

READY

2

AWAY

5

TEST

8

CODE

0

3

STAY

6

BYPAS

S

9

CHIME

#

ARME

D

READY

1

OFF

4

MAX

7

INSTANT

READY

2

AWAY

5

TEST

8

CODE

0

3

STAY

6

BYPASS

9

CHIME

#

ARMED

READY

 

 
 
 
 
 

 

 
 
 
 
 
 
 

 

 

 

 

 

 

 

 

 
 
 
 
 

 

 
 

 

 

 

 

K5305-7PRV1  5/04   Rev. A (P2) 

 

 

Содержание Counterforce CFV15P

Страница 1: ...ogramming Guide ON OFF 1 OFF 4 MAX 7 INSTANT READY 2 AWAY 5 TEST 8 CODE 0 3 STAY 6BYPASS 9CHIME ARMED READY 1 OFF 4 MAX 7INSTANT READY 2 AWAY 5 TEST 8 CODE 0 3 STAY 6BYPASS 9CHIME ARMED READY K5305 7P...

Страница 2: ...s 57 Function Key Programming Unlabeled keypad keys known as ABCD keys for special functions 58 Zone Programming Same options as 56 mode but with fewer prompts Intended for those familiar with Expert...

Страница 3: ...UNDER BELL TIMEOUT 1 0 none 1 4 min 2 8 min 3 12 min 4 16 min UL For residential fire alarm installation must be set for a minimum of 4 min option 1 for UL Commercial Burglary installations must be mi...

Страница 4: ...nt 1 15 secs 2 30 secs etc UL Grade AA must be 0 Grade A must be 15 max 55 DYNAMIC SIGNALING PRIORITY 0 0 Primary Dialer first 1 Long Range Radio first For UL Commercial Burglary installations that us...

Страница 5: ...s option not for use in UL installations 0 assign cross zones on zone list 4 using 81 Menu mode 0 15 seconds 6 2 1 2 min 12 8 min 1 30 seconds 7 3 min 13 10 min 2 45 seconds 8 4 min 14 12 min 3 60 sec...

Страница 6: ...ANDS These are commands not data fields See page 2 PAGER OPTIONS 160 172 160 PAGER 1 PHONE No Enter up to 20 digits 0 9 11 12 13 2 second pause 161 PAGER 1 CHARACTERS Enter the optional prefix charact...

Страница 7: ...rsor back moves forward Press when done to continue TOUCH SCREEN DEVICE ENABLE 189 AUI DEVICE 1 and 2 ENABLE for Touch Screen Style Keypads 1 1 AUI 1 AUI 2 System supports up to two touch screen style...

Страница 8: ...alarms when armed disarmed 1 don t show alarms when armed show alarms trbles faults when disarmed 3 never show any alarms trbles faults 0 no 4 power reset after fault by code OFF 12 verification see...

Страница 9: ...9 BR 50 BR 51 BR 52 BR 53 BR 54 BR 55 BR 56 BR 95 09 01 00 N A N A N A keypad 1 96 08 01 00 N A N A N A keypad 3 99 07 01 00 N A N A N A keypad NOTES Zone Type see definitions on page 12 Hardwire Type...

Страница 10: ...ER DEVICE X 10 MAPPING Must program before using 80 OUTPUT TYPE Relay X10 Output No Module Addr Pos 1 4 Unit No Description 01 02 03 04 05 06 07 08 17 On Board Trigger 1 norm output 18 On Board Trigge...

Страница 11: ...11 12 13 14 15 16 17 18 19 20 21 22 23 24 ZONE TYPE SYSTEM OPERATION Choices for Zone Types are 00 Not Used 05 Trouble Day Alarm Night 10 Interior w Delay 24 Silent Burglary 01 Entry Exit 1 06 24 Hr...

Страница 12: ...keypad and an audible external alarm Type 08 24 hour Auxiliary Alarm Assign to a zone containing an emergency button or to a zone containing monitoring devices such as water or temperature sensors Se...

Страница 13: ...sounding resumes if bell timeout has not expired and reports that were stopped are sent Types 90 91 Installer Defined These zone types can be programmed for various custom responses See data fields 1...

Страница 14: ...53 POWER R 155 RADIO 156 REAR 157 RECREATION 159 REFRIGERATION 160 RF 161 RIGHT 162 ROOM 163 ROOF S 164 SAFE 165 SCREEN 166 SENSOR 167 SERVICE 168 SHED 169 SHOCK 170 SHOP 171 SHORT 173 SIDE 174 SKYLIG...

Страница 15: ...5 1 No Response 23 2 Disarm 22 2 Arm Stay 20 3 Arm Away 21 3 Arm Away 21 4 Arm Stay 20 4 Disarm 22 TEMPLATE 3 1 24 hour audible 7 TEMPLATE 6 1 24 hour audible 7 2 Disarm 22 2 Arm Stay 20 3 Arm Away 21...

Страница 16: ...ND OR RING GRAY TIP GREEN RING RED INCOMING PHONE LINE NOT USED ZONE 1 ZONE 2 HI LO HI LO ZONE 3 ZONE 4 HI LO HI LO ZONE 6 HI LO HI LO MAXIMUM LOOP RESISTANCE EACH ZONE 300 OHMS PLUS EOLR RESPONSE ZON...

Отзывы: