background image

SmartView

Installation and Use

Page 40

Problem:

Mouse causes channel to change.

Action:

Some cheaper mice are not fully compatible with the SmartView and can lose data
causing the channel to be changed (if mouse switching of channels is enabled). If
you experience this problem then change the mouse and use a Microsoft, Logitech,
IBM, Compaq or Hewlett-Packard type. Ensure that you are using a Microsoft
compatible mouse driver on your PC. Some other manufacturers’ drivers may switch
the mouse to use a proprietary mouse data format not supported by the SmartView.
If you have unplugged and re-connected a mouse to the SmartView then ensure that
you reset it using the mouse reset function (see section 3.3).

Problem:

Mouse jumps around the screen after disconnecting the mouse cable or powering
down the SmartView.

Action:

If you have disconnected and re-connected a CPU mouse cable or you have
powered down the SmartView then the mouse data format may be out of
synchronisation with that required by the PC (PS/2 or Intellimouse). Try the ‘restore
Intellimouse’ function (F6) to resolve the problem or re-power the CPU.

Problem:

SmartView does not power on correctly (display is blank or stuck after power on).

Action:

Switch the SmartView off and leave for 10 seconds. Re-power the SmartView,
preferably from a switch on a wall socket rather then by plugging in the connector to
the rear panel of the SmartView. Try switching off all the connected CPUs and
switching on the SmartView first. If this action does not resolve the problem then
there is a fault with the SmartView.

Содержание SMART View PRO SV12PRO

Страница 1: ...V Vi ie ew w PRO I N S T A L L A T I O N U S E www addertec com 16 Port SMARTView PRO SV16PRO 12 Port SMARTView PRO SV12PRO 8 Port SMARTView PRO SV8PRO 4 Port SMARTView PRO SV4PRO SMART V V i i e e w...

Страница 2: ...tView Replace the power adapter with a manufacturer approved type only Do not use power adapter if power adapter case becomes damaged cracked or broken or if you suspect that it is not operating prope...

Страница 3: ...ceiver is connected d Consult the supplier or an experienced radio TV technician for help FCC Compliance Statement United States This equipment generates uses and can radiate radio frequency energy an...

Страница 4: ...ation options 14 2 7 Other useful installation information 16 2 8 Re enabling a disconnected PS 2 mouse 17 2 8 Hot plugging the SmartView into running systems and re enabling disconnected PS 2 CPU mou...

Страница 5: ...ng between local and remote ports 31 4 4 Mouse mode and mouse switching of channels 32 4 5 Keyboard hotkey combination 33 4 6 Firmware functions version query mouse restore and reset 34 4 7 Display ap...

Страница 6: ...cascaded to provide a video switching network OVQ circuit ensures Optimum Video Quality even over extended distances Password security prevents unauthorised use Remote control module for convenient o...

Страница 7: ...Power supply suitable for your country 6 x stick on self adhesive rubber feet 2 x mounting brackets for fixing the unit into a 19 inch rack 4 x screws for fixing mounting brackets to SmartView Pro 6...

Страница 8: ...SmartView Installation and Use Page 7 1 3 Product information Fig 1 SmartView SV8PRO Fig 2 Remote control pad display optional accessory for 4 8 port models...

Страница 9: ...SmartView Installation and Use Page 8 Fig 3 SmartView SV4PRO...

Страница 10: ...SmartView Installation and Use Page 9 Fig 4 SmartView SV12PRO...

Страница 11: ...SmartView Installation and Use Page 10 Fig 5 SmartView SV16PRO...

Страница 12: ...annel then you will need a three button mouse or an IntelliMouse The SmartView supports Internet Mice that are compatible with the Microsoft IntelliMouse These are fitted with a wheel or other scroll...

Страница 13: ...o sets of keyboards monitors and mice then you do not need to use the same brands or mix of devices on each control port For example you may wish to use a two button PS 2 mouse on one port and a Micro...

Страница 14: ...iew is supplied pre configured with factory defaults which are suitable for most applications There are a number of more advanced options which can be set by the user These are stored in the SmartView...

Страница 15: ...inactivity B8 Blank screen after 20 minutes of inactivity D1 Menu appears with magenta blue background and green highlight default D2 Menu appears with red blue background and green highlight D3 Menu...

Страница 16: ...T7 30 seconds autoscan delay time before switching to next port T8 60 seconds autoscan delay time before switching to next port U1 SmartView channels are switchable using a 3 button mouse or IntelliM...

Страница 17: ...2 mouse connection from a PC whilst the PC is on Due to the design of PS 2 mice communications the mouse function on the PC will be lost and you will have to re boot the PC to regain normal operation...

Страница 18: ...f any of the other ports on the switch or the CPU connections 2 9 Hot plugging the SmartView into running systems and re enabling disconnected CPU PS 2 mouse connections It is adviseable to switch off...

Страница 19: ...system Driver type Likely expected Suggested Connected at bootup data format restoration PS 2 PS 2 only PS 2 F5 PS 2 IntelliMouse PS 2 F5 IntelliMouse SmartView PS 2 only PS 2 F5 IntelliMouse SmartVi...

Страница 20: ...nd operates even when the SmartView is powered off The red status lights A and B show the activity status of the local and remote keyboard monitor mouse control ports When port A is active port B is d...

Страница 21: ...UTO key puts the SmartView into auto scan mode The ports scanned and the scan time can be selected by options L and T in configure mode see section 4 2 AUTO and SELECT keys pressed together Lock funct...

Страница 22: ...autoscan mode is selected the segments will illuminate in sequence in a clockwise direction interspersed with a display of the currently selected channel If SmartView has been locked P will be displa...

Страница 23: ...er control port may be used 3 6 Keyboard hotkey control SmartView can be conveniently controlled by selecting channel autoscan mode or security locking from the keyboard All of the hotkey control comm...

Страница 24: ...signal and displays 0 This will cause some monitors to go into standby mode or switch off The video signal can be re enabled by selecting a channel HOTKEYs and L disables the SmartView s shared keyboa...

Страница 25: ...a To select channel 12 on a 12 or 16 port SmartView press ba ba1 1 release 1 1 press 2 2 release 2 2ba ba 3 7 On Screen Menu control SmartView Pro can conveniently select a computer using the integral...

Страница 26: ...ired Adding a computer to the menu list With the menu visible on the screen press the INSERT key This will cause a new Computer entry field to be inserted on the menu This is highlighted in red with a...

Страница 27: ...er from the menu list With the menu visible on the screen highlight the computer to be deleted and press the DELETE key To confirm deletion press ENTER To abandon deletion press ESC Editing a computer...

Страница 28: ...own the central mouse button or wheel button and click on the left hand mouse button The channel will then change 3 9 RS232 control SmartView Pro can be controlled by a remote RS232 device To select a...

Страница 29: ...d hold down the hotkey keys then press 2 followed by 3 whilst keeping the hotkey keys pressed This will have the effect of connecting to port 3 of the SmartView which is connected into port 2 of the f...

Страница 30: ...SmartView Installation and Use Page 29 A typical cascade of two SmartViews...

Страница 31: ...inutes of inactivity B5 Blank screen after 8 minutes of inactivity B6 Blank screen after 12 minutes of inactivity B7 Blank screen after 16 minutes of inactivity B8 Blank screen after 20 minutes of ina...

Страница 32: ...he on screen menu the keypad the keyboard hotkeys or the mouse Many modern monitors are fitted with automatic power save relays and will switch off after a few seconds if connected to an inactive PC I...

Страница 33: ...SmartView then it is not available for use with PC software although the function of an IntelliMouse wheel is not affected Consequently in modes U1 U2 and U4 the SmartView reports to the PCs that a 2...

Страница 34: ...ode or secure the product so that the password needs to be typed before it can be used again The following keyboard hotkey combinations can be selected These hotkey combinations are used together with...

Страница 35: ...3 Display firmware third digit F5 Restore PS 2 mouse function to the currently selected CPU s mouse port F6 Restore IntelliMouse function to the currently selected CPU s mouse port F8 Reset all config...

Страница 36: ...ot case sensitive and can be any combination of key strokes including the function keys but excluding the ctrl alt shift and enter keys When you have typed in your password type enter to register it i...

Страница 37: ...same query code so an alternative query code was provided to ensure compatibility Either query code may be used but you should make sure that all cascaded SmartView units are set to use the same quer...

Страница 38: ...erate at distances of 20 metres A2 SmartView to PCs 1 to 16 Cable specifications Video 15 pin high density male D connector to 15 pin high density male D connector wired as a standard VGA PC to monito...

Страница 39: ...the RS232 port on a PC Cables should be no longer than 30 metres A3 Expansion port pin assignments The 15 way D connector located on the back of the SmartView provides connections for the remote contr...

Страница 40: ...and the activity indicator dot on 7 segment display does not flash then the SmartView is not receiving data from the mouse Check the mouse connection to the SmartView try resetting the mouse using the...

Страница 41: ...nction see section 3 3 Problem Mouse jumps around the screen after disconnecting the mouse cable or powering down the SmartView Action If you have disconnected and re connected a CPU mouse cable or yo...

Страница 42: ...o wake up The operation therefore appears to hang To restore the video under these conditions press escape return or change the channel using HOTKEYs channel number Alternatively you may wish to avoid...

Страница 43: ...SmartView Installation and Use Page 42 Notes...

Страница 44: ...Vi ie ew w PRO INSTALLATION USE ADDERTechnology Limited Technology House TrafalgarWay Bar Hill Cambridge CB3 8SQ England T 44 0 1954 780044 F 44 0 1954 780081 sales addertec com www addertec com SV PR...

Отзывы: