background image

 

Page | 3 

ePowerSwitch 8XS 

 

SAFETY INSTRUCTIONS: To be read before use! 

 

 

 

NOTE 

 

  The ePowerSwitch devices can only be installed by qualified people with the following installation 

and use instructions. The manufacturer disclaims all responsibility in case of a bad utilization of 
the ePowerSwitch devices and particularly any use with equipments that may cause personal 
injury or material damage. 

 

  This equipment is designed to be installed on a dedicated circuit that must have a circuit breaker 

or fuse protection.  

 

  The electrical power sockets used to plug the power cords of the ePowerSwitch devices must be 

close to the ePowerSwitch devices and easily accessible. 

 

  Check that the power cords, plugs and sockets are in good condition. 

 

  The ePowerSwitch devices can only be connected to three-wire 230 VAC (50-60Hz) sockets. 

 

  Always plug the ePowerSwitch devices into properly grounded power sockets (two poles plus 

ground). 

 

  Never exceed 10 Amp total load for each group of 4 power outlets of an ePowerSwitch device. 

  The ePowerSwitch devices are intended for indoor use only. Do NOT install them in an area 

where excessive moisture or heat is present. 

 

  Always disconnect the 2 (two) power cords of the ePowerSwitch device if you want to intervene 

on the ePowerSwitch device or on the equipment powered from the ePowerSwitch device. 

 

  The power outlets of the ePowerSwitch devices are not circuit breakers! If you want to intervene 

on equipments connected to an ePowerSwitch device you must disconnect these equipments 
from the ePowerSwitch device. 

 

  Do NOT attempt to disassemble the ePowerSwitch devices, they contain potentially hazardous 

voltages. 

 

  The ePowerSwitch devices contain no user serviceable parts and repairs are to be performed by 

factory trained service personnel only. 

 

  Always use a shielded cable for the Ethernet connection. 

 

 

Содержание ePowerSwitch 8XS

Страница 1: ...ePowerSwitch 8XS User guide Version 02 2011 www neol com...

Страница 2: ......

Страница 3: ...sion of NEOL S A S This documentation the ePowerSwitch 8M R2 its peripherals accessories and accompanying software were produced with great care yet errors are possible NEOL S A S assumes no responsib...

Страница 4: ...32 port 11 6 2 Using the RS485 port 11 6 3 Commands 11 6 3 1 Controlling of the power outlet s 12 6 3 2 Reading out the power outlet status 13 6 3 3 Setting of the power up delays 14 6 3 4 Reading out...

Страница 5: ...kets Always plug the ePowerSwitch devices into properly grounded power sockets two poles plus ground Never exceed 10 Amp total load for each group of 4 power outlets of an ePowerSwitch device The ePow...

Страница 6: ...ses secteur correctement mises la terre deux prises terre pour brancher les c bles secteur des quipements ePowerSwitch Ne jamais d passer un courant total de 10 Amp pour chaque entr e secteur des quip...

Страница 7: ...erver or a PC The number of the controlled power outlets can be extended by connecting the ePowerSwitch Satellite unit to an ePowerSwitch Master 4M 8M 8M R2 8M 32 or VizioGuard 1 1 Package list The fo...

Страница 8: ...s of power outlet 7 On Off 8 Red Status of power outlet 8 On Off Dip Switches 1 4 physical address of device 5 6 xBus termination RS232 SUB D 9F Connector RS232 serial port with DB 9 female connector...

Страница 9: ...7 ePowerSwitch 8XS 3 2 Back Power input B 230 VAC 10 Amp Power outlets Group B Power outlets 5 8 230 VAC max 10 Amp Power outlets Group A Power outlets 1 4 230 VAC max 10 Amp Power input A 230 VAC 10...

Страница 10: ...t Link up cable to the first satellite Link up cable to the next satellites EPS M8 RJ9M DB9M R f RJ9 DB9M 180 must be ordered separately up to 4 Satellite units RJ45M RJ45M or RJ11M RJ45M see supplied...

Страница 11: ...f ON Off Off 4 ON ON Off Off 5 Off Off ON Off 6 ON Off ON Off 7 Off ON ON Off 8 ON ON ON Off 9 Off Off Off ON 10 ON Off Off ON 11 Off ON Off ON 12 ON ON Off ON 13 Off Off ON ON 14 ON Off ON ON 15 Off...

Страница 12: ...ls display the connection status of the I O extension module and the status of the dry contact inputs If you log in as a user you will be able to control individually all the power outlets and all the...

Страница 13: ...3 Commands Run a terminal program such as Windows HyperTerminal or the MicroTerminal program on the CD folder miscellaneous and configure the appropriate serial port with the following settings 9 600...

Страница 14: ...t1 delay to execute the command 1 to 255 set the delay in sec to execute the command t2 restart delay 1 to 255 set the restart delay in sec If t2 is not specified the used restart delay is the defaul...

Страница 15: ...address of the ePowerSwitch 8XS y number of the Power Outlet 1 to 8 specify the number of the power outlet z status 0 status of the corresponding power outlet is OFF 1 status of the corresponding powe...

Страница 16: ...wer outlet 3 of ePowerSwitch 16 to 10 sec The ePowerSwitch 8XS accepts lower case and upper case commands The ePowerSwitch 8XS sends its reply only after having received a valid command terminated by...

Страница 17: ...sec The ePowerSwitch 8XS accepts lower case and upper case commands The ePowerSwitch 8XS sends its reply only after having received a valid command terminated by the character CR 6 3 6 Reading out of...

Страница 18: ...Set Power Up Default Status of the Power Outlet 5 of ePowerSwitch 16 to OFF The ePowerSwitch 8XS accepts lower case and upper case commands The ePowerSwitch 8XS sends its reply only after having rece...

Страница 19: ...lanations Parameter Value Function Remark x address of the ePowerSwitch 1 to 16 specifies the address of the ePowerSwitch 8XS y counter 0 reads the number of power up cycles of the ePowerSwitch 8XS 1...

Страница 20: ...upper case commands The ePowerSwitch 8XS sends its reply only after having received a valid command terminated by the character CR 6 3 11 Restoring to factory settings This command enables to restore...

Страница 21: ...RS 485 RJ 45 Nominal input voltage 230 V 50Hz Input power outlet IEC 320 Output voltage 230 V 50Hz Output power outlet IEC 320 Maximum total current 2 x 10 A LEDs 1 for power supply A 1 for power supp...

Страница 22: ...uncil Directives 2004 108 EEC Standards to Which Conformity declared EN 60950 1 EN 55022 EN 55024 Manufacturer s Name and Address NEOL S A S 4 Rue Nationale 67800 BISCHHEIM FRANCE Type of Equipment Po...

Отзывы: