background image

 

Page | 1 

ePowerSwitch 8XS 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
© Copyright by NEOL S.A.S - 4 Rue Nationale, 67800 BISCHHEIM, France 
 
Printed in France 
 
All rights reserved. No part of this documentation, accompanying software or other components of the 
described product may be reproduced or transmitted in any form or by any means, electronic or 
mechanical, including photocopying and recording, for any purpose other than the personal use of the 
purchaser without the express written permission of NEOL S.A.S. 
 
This documentation, the ePowerSwitch 8M+

R2

, its peripherals, accessories and accompanying software 

were produced with great care, yet errors are possible.  
NEOL S.A.S assumes no responsibility for errors within the documentation, the hardware or the software. 
NEOL S.A.S reserves the right to change programs or the documentation from time to time without 
informing the user, errors and omissions excepted. 
 
Trademarks 

Neol and ePowerSwitch are registered trademarks of NEOL S.A.S. All other brand names and 
product names used in this book are trade names, service marks, trademarks, or registered 
trademarks of their respective owners. 

 

 

 

 
 

 

 

 

Содержание ePowerSwitch 8XS

Страница 1: ...ePowerSwitch 8XS User guide Version 02 2011 www neol com...

Страница 2: ......

Страница 3: ...sion of NEOL S A S This documentation the ePowerSwitch 8M R2 its peripherals accessories and accompanying software were produced with great care yet errors are possible NEOL S A S assumes no responsib...

Страница 4: ...32 port 11 6 2 Using the RS485 port 11 6 3 Commands 11 6 3 1 Controlling of the power outlet s 12 6 3 2 Reading out the power outlet status 13 6 3 3 Setting of the power up delays 14 6 3 4 Reading out...

Страница 5: ...kets Always plug the ePowerSwitch devices into properly grounded power sockets two poles plus ground Never exceed 10 Amp total load for each group of 4 power outlets of an ePowerSwitch device The ePow...

Страница 6: ...ses secteur correctement mises la terre deux prises terre pour brancher les c bles secteur des quipements ePowerSwitch Ne jamais d passer un courant total de 10 Amp pour chaque entr e secteur des quip...

Страница 7: ...erver or a PC The number of the controlled power outlets can be extended by connecting the ePowerSwitch Satellite unit to an ePowerSwitch Master 4M 8M 8M R2 8M 32 or VizioGuard 1 1 Package list The fo...

Страница 8: ...s of power outlet 7 On Off 8 Red Status of power outlet 8 On Off Dip Switches 1 4 physical address of device 5 6 xBus termination RS232 SUB D 9F Connector RS232 serial port with DB 9 female connector...

Страница 9: ...7 ePowerSwitch 8XS 3 2 Back Power input B 230 VAC 10 Amp Power outlets Group B Power outlets 5 8 230 VAC max 10 Amp Power outlets Group A Power outlets 1 4 230 VAC max 10 Amp Power input A 230 VAC 10...

Страница 10: ...t Link up cable to the first satellite Link up cable to the next satellites EPS M8 RJ9M DB9M R f RJ9 DB9M 180 must be ordered separately up to 4 Satellite units RJ45M RJ45M or RJ11M RJ45M see supplied...

Страница 11: ...f ON Off Off 4 ON ON Off Off 5 Off Off ON Off 6 ON Off ON Off 7 Off ON ON Off 8 ON ON ON Off 9 Off Off Off ON 10 ON Off Off ON 11 Off ON Off ON 12 ON ON Off ON 13 Off Off ON ON 14 ON Off ON ON 15 Off...

Страница 12: ...ls display the connection status of the I O extension module and the status of the dry contact inputs If you log in as a user you will be able to control individually all the power outlets and all the...

Страница 13: ...3 Commands Run a terminal program such as Windows HyperTerminal or the MicroTerminal program on the CD folder miscellaneous and configure the appropriate serial port with the following settings 9 600...

Страница 14: ...t1 delay to execute the command 1 to 255 set the delay in sec to execute the command t2 restart delay 1 to 255 set the restart delay in sec If t2 is not specified the used restart delay is the defaul...

Страница 15: ...address of the ePowerSwitch 8XS y number of the Power Outlet 1 to 8 specify the number of the power outlet z status 0 status of the corresponding power outlet is OFF 1 status of the corresponding powe...

Страница 16: ...wer outlet 3 of ePowerSwitch 16 to 10 sec The ePowerSwitch 8XS accepts lower case and upper case commands The ePowerSwitch 8XS sends its reply only after having received a valid command terminated by...

Страница 17: ...sec The ePowerSwitch 8XS accepts lower case and upper case commands The ePowerSwitch 8XS sends its reply only after having received a valid command terminated by the character CR 6 3 6 Reading out of...

Страница 18: ...Set Power Up Default Status of the Power Outlet 5 of ePowerSwitch 16 to OFF The ePowerSwitch 8XS accepts lower case and upper case commands The ePowerSwitch 8XS sends its reply only after having rece...

Страница 19: ...lanations Parameter Value Function Remark x address of the ePowerSwitch 1 to 16 specifies the address of the ePowerSwitch 8XS y counter 0 reads the number of power up cycles of the ePowerSwitch 8XS 1...

Страница 20: ...upper case commands The ePowerSwitch 8XS sends its reply only after having received a valid command terminated by the character CR 6 3 11 Restoring to factory settings This command enables to restore...

Страница 21: ...RS 485 RJ 45 Nominal input voltage 230 V 50Hz Input power outlet IEC 320 Output voltage 230 V 50Hz Output power outlet IEC 320 Maximum total current 2 x 10 A LEDs 1 for power supply A 1 for power supp...

Страница 22: ...uncil Directives 2004 108 EEC Standards to Which Conformity declared EN 60950 1 EN 55022 EN 55024 Manufacturer s Name and Address NEOL S A S 4 Rue Nationale 67800 BISCHHEIM FRANCE Type of Equipment Po...