Welcome

Introduction

The AdderView Secure range of products are highly robust KVMA switches for 
critical applications. When information absolutely must not be leaked between 
systems or networks, the AdderView Secure units combine the necessary 
isolation with a desirable ease of use. 
AdderView Secure units are available in two port and four port versions. Both 
models combine a number of overlapping strategies that are designed and 
proven to defeat potential points of infiltration or protect against user error.  
Firstly, all channel switching is controlled only from the front panel buttons. No 
keyboard or mouse switching commands are permitted and all operations are 
continually monitored by a dedicated sub-system. Any deviation from a strictly 
ordered sequence of events will result in an error condition, where all channels 
are immediately isolated and the operator is informed via a front panel indicator.
Data Diodes, implemented within hardwired electronic circuitry, rather than 
software, are liberally employed to ensure that critical data paths can flow only 
in one direction. These data diodes ensure that a compromised peripheral, a 
keyboard for instance, cannot read information back from a connected system in 
order to transfer such details to another system. Whenever a channel is changed, 
the connected keyboard and mouse are always powered down and re-initialized 
to provide yet another level of protection against hidden peripheral malware.  
In general, the role of software within the unit has been reduced to an absolute 
minimum to avoid the possibility of subversive reprogramming. Additionally, all 
flash memory has been banished from the design, to be replaced by one-time 
programmable storage which cannot be altered. 
The outer casing contains extensive shielding to considerably reduce electromagnetic 
emissions. Additionally, the casing has been designed with as few apertures as 
possible to reduce the possibility of external probing and several primary chassis 
screws are concealed by tamper-evident seals to indicate any unauthorized 
internal access. Shielding extends also to the internal circuitry with all channels 
providing a minimum of 60dB crosstalk separation between computer input 
signals and any signals from the other computers at frequencies up to 100MHz.
These are just a few of the many strategies and innovations that have been 
combined to ensure separation between differing systems. Numerous other 
defences lie in wait to defeat any potential threat.     

Various strategies are employed to ensure complete 
separation between the switched channels: 
•  One-way 

Data Diodes

 are used on 

keyboard and mouse communication 
channels so that data isolation does 
not rely on software.

•  The keyboard and mouse are powered 

down and re-initialized during every 
channel switch to ensure that they 
cannot act as transport media for 
malicious data between computers. 

•  Many aspects of operation are 

internally monitored. For instance, if a 
second channel attempts to open while 
another is still active, all operation 
will be instantly halted and an error 
condition signalled to the user.      

Hard wired 

Data 

Diodes

 enforce a 

one-way flow on 
information.

Individually colored 
indicators provide clear 
visual feedback about the 
currently selected channel.

Channel switching 
is by physical 
button press only, 
no keyboard or 
mouse codes are 
permitted.

Common keyboard, mouse, video 
monitor and speakers are able 
to access multiple high security 
computers/networks, safe in the 
knowledge that data will not be 
transferred from one to another, 
either by user error or subversive 
attack. 

The switching section is hard 
wired to allow only one channel 
to be selected at any time. This 
operation is also closely monitored 
by separate checking circuitry.  

Содержание AVSD 1002 (2port)

Страница 1: ...AdderView Secure User Guide ERR 1 2 3 4 PWR AVSD1002 2 port AVSD1004 4 port...

Страница 2: ...ations 7 Tamper evident seals 7 Links overview 7 Mounting 8 Making connections 9 Connections to computer systems 9 Connections to user console peripherals 11 Video display EDID information 13 Connecti...

Страница 3: ...rational procedures must e g re staff vetting and training ensure that as far as is reasonably possible the product is received installed and managed in accordance with the manufacturer s directions T...

Страница 4: ...ains extensive shielding to considerably reduce electromagnetic emissions Additionally the casing has been designed with as few apertures as possible to reduce the possibility of external probing and...

Страница 5: ...individually colored indicator to provide additional visual feedback Clear error indication Any unexpected operation such as an attempt to select two channels simultaneously will be signalled by the E...

Страница 6: ...e keyboard is powered down and reset at every switchover to clear stored states Mouse devices Although pointing devices don t generally process confidential data and are therefore considered to pose a...

Страница 7: ...1 2 3 4 PW R 5V 2A Power supply plus country specific mains cable Standard items Additional items AdderView Secure unit AVSD1002 2 port AVSD1004 4 port Installation CD ROM Rack brackets Including four...

Страница 8: ...r evident seals It may be a policy of your organization to fit proprietary tamper evident labels across certain chassis screws Additionally seals could be added between each connection and the unit to...

Страница 9: ...8 Mounting The AdderView Secure unit offers two main mounting methods Supplied four self adhesive rubber feet Optional rack brackets 5V 2 0A INDOOR USE ONLY 1 USER CONSOLE 4...

Страница 10: ...systems To connect a keyboard and mouse link 1 Wherever possible ensure that power is disconnected from the unit and the host computer s to be connected To connect an audio link 1 Wherever possible e...

Страница 11: ...display could cause issues in certain high security installations please see the Video display EDID information section for further details To connect a video input 1 Wherever possible ensure that pow...

Страница 12: ...1 Wherever possible ensure that power is disconnected from the unit and the host computer s to be connected 2 At the far left side of the rear panel connect the cables from the keyboard and mouse to...

Страница 13: ...lay could cause issues in certain high security installations please see the Video display EDID information section for further details To connect a video display 1 Wherever possible ensure that power...

Страница 14: ...data to the EDID memories and no data will be made available to the computers This provides a means of clearing information about previously attached monitors Note Most analog video cards will output...

Страница 15: ...o not use an unearthed power socket or extension cable To connect the power supply 1 Attach the output connector of the power supply country specific power supplies are available to the socket on the...

Страница 16: ...o select the labeled channel When the chosen channel has been connected the adjacent indicator will illuminate continuously to confirm If the indicator flashes then the selected computer is either swi...

Страница 17: ...specialist assistance from Adder technical support Summary of threats and solutions This section provides a list of potential security threats that the AdderView Secure might face during operation an...

Страница 18: ...rmation about data flowing to another computer The user selects the wrong port Only one simple method of selecting computers is provided The selected port is clearly and unambiguously indicated on the...

Страница 19: ...shooting section then we provide a number of other solutions Adder Technology website www adder com Check the Support section of our website for the latest solutions and driver files Email support add...

Страница 20: ...exceed the cable s ampere rating Also make sure that the total ampere rating of all the devices plugged into the wall outlet does not exceed the wall outlet s ampere rating The power adapter can get...

Страница 21: ...is connected d Consult the supplier or an experienced radio TV technician for help FCC Compliance Statement United States This equipment generates uses and can radiate radio frequency energy and if n...

Страница 22: ...ay Bar Hill Cambridge CB23 8SQ United Kingdom Tel 44 0 1954 780044 Fax 44 0 1954 780081 Adder Corporation 350R Merrimac Street Newburyport MA 01950 United States of America Tel 1 888 932 3337 Fax 1 88...

Отзывы: