7351 Series Digital Multimeter Operation Manual
5.12.4 Front Panel Disabling Function
5-37
5.12.4
Front Panel Disabling Function
This function disables all panel keys on the front panel in this instrument.
The following shows how to set the front panel disabling function.
Password setting
The password is required to enable or disable the front panel keys.
A four-digit number from 0000 to 9999 can be used for the password.
Set the password according to the following procedure.
Operation
Character
display
section
1.
Press
and select
by using
and
.
MENU
SYS
2.
Press .
SYS
BEEP
3.
Select ‘PWD’ by using
and
.
SYS
PWD
4.
Press .
PWD
NEW
5.
Select the digit in the numerical value entry section by using
and .
Change the numerical value by using
and
to enter the
password.
PWD
NEW
6.
Press .
PWD
OLD
7.
Enter the current password according to the above procedure.
PWD
OLD
8.
Press .
If the correct password is entered, PASS is displayed and the
password is set.
PWD
PASS
If an incorrect password is entered, FAIL is displayed and the
procedure returns to step 3.
Re-set by using the correct password.
PWD
FAIL
9.
Press
to exit from MENU.
MENU
9 SYS
ENTER
ENTER
EXIT