6247G/6247C DC Voltage Current Source/Monitor Operation Manual
5.3 Compatibility
5-70
5.3
Compatibility
The 6247G/6247C shares the same command system as the 6240A/6241A/6242.
This section describes the compatibility with the earlier 6243/6244 models.
5.3.1
Remote Command Compatibility
The 6247G/6247C has the same functions as the 6243/6244 but does not have command compatibility.
For more information on the remote operation, refer to Section 6.7.4, "Remote Command List."
The following commands have compatibility.
•
V command
•
I command
•
D command
•
H command
•
E command
•
N command
5.3.2
Difference in Period Parameter for Pulse Source and Sweep Source
Note that the definition of the period parameter Tp is different from that of the 6243/6244.
Source mode
6240A/41A/42/47G/47C
6243/44
Pulse
DC sweep
Pulse sweep
Tp
Tds
Tp
Tds
Tp
Tds
Tp
Tds
Tp
Tds
Tp
Tds