background image

w w w . a d c . c o m   •   + 1 - 9 5 2 - 9 3 8 - 8 0 8 0   •   1 - 8 0 0 - 3 6 6 - 3 8 9 1

Spec 

Sheet

TrueNet

®

CopperTen

®

 Termination Block 

The 20-pair TrueNet

®

 CopperTen

®

 termination block is designed to suit five incoming and 

five outgoing four-pair Category 6a cables. Each IDC slot is color-coded to allow for accurate 
termination of each of the four pairs. The CopperTen termination block utilizes a disconnect 
feature making it ideal for Patch-by-Exception installations and can also be patched as a traditional 
cross-connect. The cable manager at the rear of the module ensures that cables are held in place 
securely without the need for Velcro ties.

Features: 

Transmission performance to TIA-568.B.2-10 component compliance as well as 10 Gigabit 

• 

ISO/IEC 11801 ed.2.1 extrapolated component 

• 

Color-coded for ease of termination 

• 

Each module will accommodate five four-pair UTP CopperTen cables 

• 

45-degree silver-plated IDCs provide secure, reliable gas-tight connections 

• 

Blocks can be terminated with standard termination tool or with a 110 tool 

• 

Four-pair to four-pair patch cords are available for Patch-by-Exception installations 

• 

Four-pair to RJ45 cords are available to interface with network and other equipment

• 

Содержание TrueNet Termination Block

Страница 1: ...connect The cable manager at the rear of the module ensures that cables are held in place securely without the need for Velcro ties Features Transmission performance to TIA 568 B 2 10 component compliance as well as 10 Gigabit ISO IEC 11801 ed 2 1 extrapolated component Color coded for ease of termination Each module will accommodate five four pair UTP CopperTen cables 45 degree silver plated IDCs...

Страница 2: ...cycles Modules up to 750 Patch Plugs up to 200 ELECTRICAL Transmission performance and reliability TIA 568 B 2 10 standards Voltage current rating at 25 ºC 77 ºF ambient 150 VAC at 2 5A max Insulation resistance 50 000 M at 500 VDC ENVIRONMENTAL AND SAFETY Safety compliance UL 1863 Flammability rating of plastic housing UL 94 VO Environment for use Indoors or in dry enclosure Should there be a req...

Страница 3: ...le managers 1 for each CopperTen block 12 x Label holders 6450 1 107 00 Management kit 2 x Patch cord dual cable management rings 1 x Dual patch cord cover 6450 1 103 00 Patch cord Size Color Catalog Number 4 pair to 4 pair 1 2 m 4 ft Blue 6451 2 401 10 4 pair to 4 pair 2 1 m 7 ft Blue 6451 2 401 20 4 pair to 4 pair 3 0 m 10 ft Blue 6451 2 401 30 4 pair to 4 pair 4 5 m 15 ft Blue 6451 2 401 40 4 p...

Страница 4: ...ion of this document Because we are continuously improving our products ADC reserves the right to change specifications without prior notice At any time you may verify product specifications by contacting our headquarters office in Minneapolis ADC Telecommunications Inc views its patent portfolio as an important corporate asset and vigorously enforces its patents Products or features contained her...

Отзывы: