ADC Telecommunications, Inc.
Table 19. HDSL Alarm Thresholds
Alarms
Value
Description
Default
HDSL ES 15 MIN
0 to 900
HDSL ES 15 minutes alarm is generated if the current
15-minute HDSL ES count reaches or exceeds this
threshold
17
HDSL ES 24 HOUR
0 to 65,000
HDSL ES 24 hour alarm is generated if ES 24 hour
counts become equal to or greater than this threshold
170
HDSL UAS 15 MIN
0 to 900
HDSL UAS-15 minutes alarm is generated in the
current 15-minute HDSL UAS count reaches or
exceeds this threshold
240
HDSL UAS 24 HR
0 to 65,000
HDSL UAS-24 hour alarm is generated if UAS counts
become equal to or greater than this threshold
600
HDSL LOW MARGIN
0 to 15
HDSL Low Margin alarm is generated if margin drops
equal to or less than this threshold
6