![ADC HRU-419 HiGain Скачать руководство пользователя страница 32](http://html1.mh-extra.com/html/adc/hru-419-higain/hru-419-higain_user-manual_2848162032.webp)
Installation
150-419-100-03>
24
September 25, 1998
HRU-419 List 1
Non-Doubler Applications.
The Maintenance Terminal Main menu
displays for non-doubler applications. Press the
several times to
initiate the RS-232 Craft port.
View Span Status
The View Span Status screen allows you to view the system status from the
HLU to the HRU-419. The screen shows information about the HDSL Loops
1 and 2 and the DS1 (for non-doubler applications). For doubler applications,
the available Span Status screens are dependent upon whether there are one
or two doublers.
Press
from the Maintenance Terminal Main menu to open the View Span
Status screen:
Figure 11.
View Span Status Screen for Non-Doubler Applications
You can do the following:
•
Press
to return to the previous menu.
•
Press
to update current values.
SPACEBAR
A
SPAN STATUS
HLU/ver0.0-0000:HRU/ver4.0-0FF)
TIME: 05:25:24
SPAN STATUS
DATE: 06/18/97
Circuit ID#:
ALARMS: NONE
LOOPBACK: OFF
HLU
HRU
HDSL-1 HDSL-2 HDSL-1 HDSL-2
cur/min/max cur/min/max cur/min/max cur/min/max
MARGIN: N/A
N/A
N/A
N/A
dB
PULSE ATTN:
N/A
N/A
N/A
N/A
dB
PPM OFFSET:
N/A
N/A
N/A
N/A
dB
24 HOUR ES:
00003
00003
00005
00006
seconds
24 HOUR UAS:
00000
00000
09613
09642
seconds
DS1 STATUS
HLU
HRU
24 HOUR BPV Seconds:
00003
00547
24 HOUR UAS Count:
00003
00000
Frame type:
N/A
Unframed
Code type:
N/A
B8ZS
(E)xit
(U)pdate
E
U