152-388-115-03, Issue 03
Front Panel
H2TU-C-388 List 1E
April 21, 2000
7
NREM
Network Remote Loopback
DSX-1 signal is looped back to the network at the H2TU-R.
SMJK
Remote SmartJack Loopback
DSX-1 signal is looped back to the network at the H2TU-R
SmartJack module.
DIAGNOSTIC MESSAGES
A = xx
Maximum Loop Attenuation
The Attenuation (A) message appears followed by xx, where xx is
the loop attenuation of the longest (maximum loss) span, measured
in dB.
ACQ
Acquisition
The multiplexers of the H2TU-C and H2TU-R or the H2TU-C and first
regenerator are trying to establish synchronization over the HDSL2
loop of Span 1.
ARM
HiGain System Armed
Armed to respond to Intelligent Repeater Loop (ILR) codes.
BAD RT?
No Response from H2TU-R
The H2TU-C receives no response from the H2TU-R. Therefore, the
integrity of the H2TU-R or the HDSL2 loop is questionable.
FERR
Framing Bit Error Occurred
Framing bit error occurred at H2TU-C DSX-1 input.
FLDL
Flash Download
Flash download of firmware updates.
Contact Customer Service for update procedures, as described in
“Appendix D - Product Support” on page 63
HES
HDSL2 CRC Error
H2TU-C HDSL2 Loop Cyclical Redundancy Check (CRC) error.
LBPV
Local Bipolar Violation
A bipolar violation has been received at the DSX-1 input to the
H2TU-C-388.
M=xx
HDSL2 Loop Margin
Indicates the power of the received HDSL2 signal relative to noise
(S/N with respect to 21.5 dB). Any value of 6 dB or greater is
adequate for reliable system operation.
MNGD
Managed
The H2TU-C-388 is under control of the HMU-319 Network
management unit. In this state, the front-panel craft port and push
buttons are disabled.
PWR FEED OFF
Power Feed Off
HDSL2 span power has been turned off by setting the PWFD option
to off or by using the A2LB Intelligent Office Repeater (IOR) Power
Down code.
PWR FEED ON
Power Feed On
Indicates that the HDSL2 loop is not grounded or shorted.
SIG
Signaling
The transceivers of the H2TU-C and H2TU-R (or the H2TU-C and
first regenerator) are trying to establish contact with each other over
the HDSL2 loop of Span 1.
SYSTEM INFORMATION MESSAGES
(a)
CODE xxxx
Line Code: AMI or B8ZS
The DS1 line code setting: Alternate Mark Inversion (AMI) or Bipolar
with 8-Zero Substitution (B8ZS).
FRM xxxx
Frame: SF, ESF, UNFR
Defines the type of frame pattern being received from the DSX-1:
SuperFrame (SF), Extended SuperFrame (ESF), Unframed (UNFR).
LATT xx
Loop Attenuation
The current loop attenuation threshold setting measured in dB.
LIST xx
H2TU-C-388 List Number
The list number of the H2TU-C-388.
MARG xx
Margin
The current margin threshold setting measured in dB.
VER x.xx
H2TU-C-388 Software Version
The software version number (x.xx).
(a) System Information Messages are displayed in Scroll Mode. To scroll through the messages, press the MODE and SEL
buttons for 3 or more seconds.
Table 2.
Front-panel Display Messages (Cont.)
Message
Full Name
Description
Содержание H2TU-C-388 HiGain
Страница 4: ...Inspecting Shipment 152 388 115 03 Issue 03 iv April 21 2000 H2TU C 388 List 1E ...
Страница 11: ...152 388 115 03 Issue 03 Overview H2TU C 388 List 1E April 21 2000 3 Figure 1 HDSL2 System Model ...
Страница 74: ...152 388 115 03 Issue 03 List of Abbreviations H2TU C 388 List 1E April 21 2000 66 ...