ADCP-75-192 • Issue 2 • June 2007
Page 12
© 2007, ADC Telecommunications, Inc.
Power
AC power ingress
240 VAC, 20 Amps, single phase
Battery backup options
extended
glitch
120 minutes
5 minutes
-48 volts
@25 degrees C (degrees F)
for four bands
RAN box power use
2700 Watts Max.
16 Amps Max.
cPCI rack power
-48 VDC
Optical
Fiber cable ingress
Nylon connector accommodates
cable diameters in range 0.38-
0.50 inches (0.97-1.27 cm).
For larger cable sizes, refer to the
note in .
Fiber type
Corning SMF-28 or equivalent
Optical connectors
LC
Standard on SFP transceivers
Insertion loss
0.2 dB Typical, 0.4 dB Max.
Number of fibers required
1-4 fiber runs per RAN
Fiber configuration
Star (point to point) or ring
Ran ring limited to 3 SIFs
Fiber data link protocol
OC-48
Wavelengths per fiber
with WDM option
with CWDM option
1 (1310 nm)
2 (1310/1550)
8 (1470-1610)
Without WDM/CWDM option
20 nm increments (ITU-GRID)
Optical transceiver type
SFP
Dual LC connector
Optical Tx power
-3 dBm Max, -10 dBm Min.
Finistar FTRJ-1320-1
(or equivalent)
Optical Rx sensitivity
-22 dBm Typical, -18 dBm Max.
Optical link margin
2 dB
Estimated
Optical link loss
6 dB
Estimated
Optical Rx saturation level
-3 dBm
Min. Max. operational power
Optical Rx damage level
-3 dBm
Min. Max survivable power
Optical safety class
1
ANSI Z 136.2
RF
Tuning frequency
PCS band
Cellular band
SMR 800 band
SMR 900 band
Receive Path
1850-1910 MHz
824-849 MHz
806-824 MHz
896-901 MHz
Transmit Path
1930-1990 MHz
869-894 MHz
851-869 MHz
935-940 MHz
Instantaneous bandwidth
15 MHz
Table 3. NXD RAN Specifications
ITEM
SPECIFICATION
COMMENT
Содержание Digivance CXD
Страница 12: ...ADCP 75 192 Issue 2 June 2007 Preface Page 10 2007 ADC Telecommunications Inc ...
Страница 73: ......
Страница 74: ...i www adc com ...