ADC
®
Adscope
®
658
Electronic Stethoscope
®
Instructions
for Use
IB p/n 93-658-00 rev 2.5
Printed in the U.S.A.
ADC
®
warrants its products against defects in materials and workmanship under
normal use and service as follows:
1. Warranty service extends to the original purchaser from the date of purchase.
2 years
- Electronic Chestpiece
Lifetime
- Binaurals & Tubing
2. The entire stethoscope is warranted. This warranty is only valid if the product
is registered online at
www.adctoday.com
.
What Is Covered:
Repair, or replacement of parts, and labor.
What Is Not Covered:
Transportation charges to ADC. Damages caused by abuse,
misuse, accident, or negligence, incidental, special, or consequential
damages. Batteries or damage from old batteries is not covered by the warranty.
Some states do not allow the exclusion or limitation of incidental, special, or
consequential damages, so this limitation may not apply to you.
To Obtain Warranty Service:
Send item postage paid to ADC, Attn: Service Dept.,
55 Commerce Dr., Hauppauge, NY 11788. Please include your name and
address, daytime phone no., proof of purchase, and a brief note explaining the problem.
Implied Warranty:
Any implied warranty shall be limited in duration to the terms of
this warranty and in no case beyond the original selling price (except where prohibited
by law). This warranty gives you specific legal rights and you may have other rights
which vary from state to state.
This manual is available online in a variety of
languages, follow the links for language options.
www.adctoday.com/care
To register your product visit us at
www.adctoday.com/register
FOR QUESTIONS, COMMENTS,
OR SUGGESTIONS CALL TOLL FREE:
1-800-ADC-2670
OR VISIT
www.adctoday.com/feedback
Warranty
ADC
®
55 Commerce Drive
Hauppauge, NY 11788
Inspected, assembled and
packaged in the U.S.A.
Chestpiece made in China
Headset made in Taiwan
tel: 631-273-9600
1-800-232-2670
fax: 631-273-9659
www.adctoday.com
©2019 ADC
®
. All rights reserved. No one is permitted to reproduce or duplicate in any form, this manual or
any part thereof without the expressed written permission of ADC. ADC
assumes no responsibility for any in-
jury to anyone, or for any illegal or improper use of the product that may result from failure to use the product
in accordance with the instructions, cautions, warnings, or statement of intended use published in this manual.
Guidance and Manufacturer’s Declaration
Below cables information are provided for EMC reference.
Cable
Max. cable length,
Number
Cable
Shielded/unshielded classification
DC Power Line 0.92m
Shielded 1 Set DC Power
Important information regarding electromagnetic compatibility (EMC)
This electrical medical equipment needs special precautions regarding EMC and should be
put into service according to the EMC information provided in the user manual. The equipment
conforms to this IEC 60601-1-2:2014 standard for both immunity and emissions. Nevertheless,
special precautions need to be observed:
Warning:
The equipment is intended used in professional healthcare facility environment ex-
cept for near active HF SURGICAL EQUIPMENT and the RF shielded room of an ME SYSTEM
for magnetic resonance imaging, where the intensity of EM DISTURBANCES is high. Essential
Performance of the device includes supplying continuous sound output during a medical
evaluation equal to or below 92.1 dB.
Warning:
Use of this equipment adjacent to or stacked with other equipment should be avoided
because it could result in improper operation. If such use is necessary, this equipment and the
other equipment should be observed to verify that they are operating normally.
Warning:
The use of accessories, transducers and cables other than those specified or provided
by the manufacturer of this equipment could result in increased electromagnetic emissions or
decreased electromagnetic immunity of this equipment and result in improper operation.
Warning:
Portable RF communications equipment (including peripherals such as antenna cables
and external antennas) should be used no closer than 30 cm (12 inches) to any part of the 658,
including cables specified by the manufacturer. Otherwise, degradation of the performance of
this equipment could result.
Warning:
When the AC input voltage is interrupted, the equipment will shut down and if the
power supply restored, it should be recovered by operator manually. This degradation could be
accepted because it will not lead to unacceptable risks and it will not result in the loss of basic
safety or essential performance.
Warning:
Accessories and cables provided with this device have not been tested or verified
for use with other medical electrical equipment and should not be considered interchangeable.
Table 1 - Emission
Phenomenon Compliance Electromagnetic environment
RF emissions CISPR 11 Professional healthcare
Group 1, Class B facility environment
Harmonic distortion IEC 61000-3-2 Professional healthcare
Class A facility environment
Voltage fluctuations IEC 61000-3-3 Professional healthcare
and flicker Compliance facility environment
EMI Compliance Table (Table 1)
Table 2 - Enclosure Port
Phenomenon Basic EMC Standard
Immunity test levels
Professional healthcare
facility environment
Electrostatic discharge IEC 61000-4-2
±8 kV contact
±2kV, ±4kV, ±8kV, ±15kV air
Radiated RF EM field IEC 61000-4-3
3V/m
80MHz-2.7GHz
80% AM at 1kHz
Proximity fields from RF wireless
IEC 61000-4-3 Refer to table 3
communications equipment
Rated power frequency
IEC 61000-4-8
30A/m
magnetic fields 50Hz or 60Hz
Table 4 – Input a.c. power Port
Phenomenon Basic EMC Standard
Immunity test levels
Professional healthcare
facility environment
Electrical fast transients/burst IEC 61000-4-4
Surges line-to-line IEC 61000-4-5
Conducted disturances IEC 61000-4-6
induced by RF fields
Voltage dips IEC 61000-4-11
Voltage interruptions IEC 61000-4-11
EMS Compliance Table (Tables 2-4)
Table 3 – Proximity fields from RF wireless communications equipment
Test Frequency Band Immunity test levels
(MHz) (MHz) Professional healthcare
facility environment
385
450
710
745
780
810
870
930
1720
1845
1970
2450
5240
5500
5785
380-390
430-470
704-787
800-960
1700-1990
2400-2570
5100-5800
Pulse modulation 18Hz, 27V/m
FM, ±5kHz deviation, 1kHz sine, 28V/m
Pulse modulation 217Hz, 9V/m
Pulse modulation 18Hz, 28V/m
Pulse modulation 217Hz, 28V/m
Pulse modulation 217Hz, 28V/m
Pulse modulation 217Hz, 9V/m
±2 kV
100kHz repetition frequency
±0.5 kV, ±1 kV
3V, 0.15MHz-80MHz
6V in ISM bands between 0.15MHz
and 80MHz
80%AM at 1kHz
0% UT; 0.5 cycle
At 0º, 45º, 90º, 135º, 180º, 225º, 270º
and 315º
0% UT; 1 cycle
and
70% UT; 25/30 cycles
Single phase: at 0º
0% UT; 250/300 cycles
93-658-00 rev 2.5.qxp_93-658-00 5/19/21 10:31 AM Page 1