American Dryer Corp.

112175 - 9

Installation Procedures ______________

Installation should be performed by competent technicians
in accordance with local and state codes.  In the absence of
these codes, the installation must conform to applicable
American National Standards: ANSI.Z223.1-LATEST
EDITION (National Fuel Gas Code) or ANSI/NFPA NO. 70-
LATEST EDITION (National Electrical Code) or in Canada,
the installation must conform to Canadian Standards: CAN/
CGA-B149.1-M91 (Natural Gas) or CAN/CGA-B149.2-M91
(L.P. Gas) or LATEST EDITION (for General Installation and
Gas Plumbing) or Canadian Electrical Codes Parts 1 & 2
CSA C22.1-1990 or LATEST EDITION (for Electrical
Connections).

Unpacking / Setting Up _______________

Remove protective shipping material (i.e., plastic wrap, and/
or optional shipping box) from dryer.

The dryer can be moved to its final location while still
attached to the pallet or with the pallet removed.  To unpallet
the dryer, locate and remove the four bolts securing the base
of the dryer to the wooden pallet.  Two are inside the lower
back guard at the rear base and two are located at the front
base.  To remove the bolt located in the front, remove the lint
door.  Once the bolts are removed, slide the dryer off the
pallet.

With the pallet removed, to make it easier to slide the dryer
into its final position, slightly lower all four leveling legs, so
that the dryer will slide on the legs instead of the base frame.
The dryer is equipped with four leveling legs, one at each
corner of the dryer base.

To increase bearing life and improve efficiency, the dryer
should be tilted slightly to the rear.

Location of the Dryer ________________

Before installing the dryer, be sure the location conforms to
local codes and ordinances.  In the absence of such codes
or ordinances the location must conform with the National
Fuel Gas Code ANSI.Z223.1 LATEST EDITION, or in Canada,
the installation must conform to applicable Canadian
Standards: CAN/CGA-B149.1-M91 (Natural Gas) or CAN/
CGA-B149.2-M91 (L.P. Gas) or LATEST EDITION (for General
Installation and Gas Plumbing).

The dryer must be installed on a sound level floor capable
of supporting its weight.  Carpeting must be removed from
the floor area that the dryer is to rest on.

IMPORTANT:

 “The dryer must be installed on

noncombustible floors only.”

The dryer must not be installed or stored in an area where it
will be exposed to water and/or weather.

The dryer is for use in noncombustible locations.

The dryer must be installed with provisions for adequate air
supply as noted in this manual (refer to Fresh Air Supply
Requirements section).

Clearance provisions must be made from noncombustible
construction as noted in this manual (refer to Dryer
Enclosure Requirements section).

Provisions must be made for adequate clearances for
servicing and for operation as noted in this manual (refer to
Dryer Enclosure Requirements section).

Dryer must be exhausted to the outdoors in an area where
correct exhaust venting can be achieved as noted in this
manual (refer to Exhaust Requirements section).

Dryer must be located in an area where correct exhaust
venting can be achieved as noted in this manual (refer to
Exhaust Requirements section).

IMPORTANT:

 Dryer must be installed in a location/

environment, which the ambient temperature remains
between 40° F (4.44° C) and 130° F (54.44° C).

Dryer Enclosure Requirements ______

Bulkheads and partitions should be made of non-
combustible materials and must be located a minimum of
12-inches (30.48 cm), 18-inches (45.72 cm) or more is
recommended for ease of installation, maintenance, and
service, above the dryer outer top, except along the front of
the dryer, which may be closed in if desired.  The clearance
between the bulkhead header and the dryer must be a
minimum of 4-inches (10.16 cm) and must not extend more
than 4-inches (10.16 cm) to the rear of the front.

IMPORTANT:

 If the dryer is installed in a closet type

enclosure there must be no other fuel burning appliance
installed in the same closet.

Dryers may be positioned sidewall to sidewall.  However, a
1/16” (1.5875 mm) minimum allowance must be made for
opening and closing of the control door and the lint door.  It
is suggested that the dryer be positioned about 2 feet (0.61
meters) away from the nearest obstruction for ease of
installation, maintenance, and service (to be measured from
the back guard).  Refer to the illustration below for details.

Clearances shown are minimum dimensions to nearest
combustible materials.

NOTE A:

12-inch (30.48 cm) minimum, 18-inches (45.7 cm) is suggested for
ease of maintenance.

NOTE B:

12-inch (30.48 cm) minimum, 24-inches (61.0 cm) is suggested for
ease of maintenance.

NOTE:

 Fresh air considerations are important for proper

and efficient operation.

Содержание AD-333

Страница 1: ...s de bien suivre les instructions données dans cette notice pour réduire au minimum le risque d incendie ou d explosion ou pour éviter tout dommage matériel toute blessure ou la mort Ne pas entreposer ni utiliser d essence ni d autres vapeurs ou liquides inflammables à proximité de cet appareil ou de tout autre appareil QUE FAIRE SI VOUS SENTEZ UNE ODEUR DE GAZ Ne pas tenter d allumer d appareils ...

Страница 2: ...__________________________________________ ____________________________________________________________________________________________________ Replacement parts can be obtained from your reseller or the ADC factory When ordering replacement parts from the factory you can FAX your order to ADC at 1 508 678 9447 or telephone your order directly to the ADC Parts Department at 1 508 678 9000 Please s...

Страница 3: ...and or weather The wiring diagram for the dryer is located in the front electrical control box area Table of Contents _________________ Proposition 65 Use of this product could expose you to substances from fuel combustion that contain chemicals known to the State of California to cause cancer birth defects and other reproductive harm In the State of Massachusetts the following installation instru...

Страница 4: ...rubber and also may be a fire hazard The possible presence of residual quantities of aggressive or decomposed chemicals in the load may produce damage to the machine and harmful fumes A program should be established for the inspection and cleaning of lint in the burner area exhaust ductwork and area around the back of the dryer The frequency of inspection and cleaning can best be determined from e...

Страница 5: ..._____________________________________________________________________________________ _________________________________________________________________________________________________________________________________ _________________________________________________________________________________________________________________________________ ______________________________________________________...

Страница 6: ...TRUCK 30 33 VOLTAGE AVAILABLE 120 240V 1 3ø 2 3w 50 60 Hz APPROXIMATE NET WEIGHT 675 lb 306 kg APPROXIMATE SHIPPING WEIGHT 710 lb 322 kg AIRFLOW PER POCKET 60 Hz 400 cfm 11 3 cmm 50 Hz 340 cfm 9 6 cmm HEAT INPUT PER POCKET 72 000 Btu hr 18 143 kcal hr EXHAUST CONNECTION DIAMETER 8 20 3 cm COMPRESSED AIR CONNECTION N A COMPRESSED AIR VOLUME N A INLET PIPE CONNECTION PER POCKET 1 2 F N P T Specifica...

Страница 7: ...dclaundry com 7 Specifications _____________________________________________________________________ NOTE The manufacturer reserves the right to make changes in specifications at any time without notice or obligation ...

Страница 8: ...e installed on noncombustible floors only The dryer must not be installed or stored in an area where it will be exposed to water and or weather The dryer is for use in noncombustible locations The dryer must be installed with provisions for adequate air supply as noted in this manual refer to Fresh Air Supply Requirements section Clearance provisions must be made from noncombustible construction a...

Страница 9: ...ews or other obstructions which will collect lint Additionally inspection doors should be installed at strategic points in the exhaust ductwork for periodic inspection and cleaning Inadequate exhaust facilities may cause high temperature limit switches or airflow switches to shut off the dryers Do not disable the switches which are provided for your safety Instead investigate the exhaust ducting A...

Страница 10: ...ain duct run from the last dryer to where it exhausts to the outdoors is unusually long over 30 feet 9 1 meters or has numerous elbows more than one in it Single Dryer Venting 8 Inch Duct IMPORTANT A minimum exhaust duct size of 8 inches 20 3 cm must be used For an 8 inch 20 3 cm run where a maximum of two elbows are used refer to the illustration below the ductwork from the dryer outlet must not ...

Страница 11: ...es grounding must conform to applicable requirements of the National Electrical Code ANSI NFPA NO 70 LATEST EDITION or in Canada the installation must conform to applicable Canada Standards Canadian Electrical Codes Parts 1 2 CSA C22 1 1990 or LATEST EDITION The ground connection may be to a proven earth ground at the location service panel For added personal safety when possible it is suggested t...

Страница 12: ...a The dryer must be isolated from the gas supply piping system by closing its individual manual shutoff valve during any pressure testing of the gas supply system at test pressures equal to or less than 1 2 psig 3 5 kPa Type of Gas Manifold Pressure In Line Pressure Natural 3 5 in wc 6 0 12 0 in wc 8 7 mb 14 92 29 9 mb Liquid Propane 10 5 in wc 11 0 in wc 26 1 mb 27 4 mb WARNING Fire or explosion ...

Страница 13: ... All components materials must conform to National Fuel Gas Code Specifications ANSI Z223 1 LATEST EDITION or in Canada CAN CGA B149 1 M91 Natural Gas or CAN CGA B149 2 M91 L P Gas or LATEST EDITION for General Installation and Gas Plumbing as well as local codes and ordinances and must be done by a qualified professional It is important that gas pressure regulators meet applicable pressure requir...

Страница 14: ...dels be sure that all gas shutoff valves are in the open position Be sure all back guard panels and service box covers have been replaced Check the lint door to ensure that it is closed and secured in place Rotate the tumbler by hand to be sure it moves freely Preoperational Test __________________ All dryers are thoroughly tested and inspected before leaving the factory However a preoperational t...

Страница 15: ...f service for a period of time the following must be performed Discontinue power to the dryer either at the external disconnect switch or the circuit breaker Discontinue the gas supply for gas models only Shut off external gas supply shutoff valve Service Parts Information __________ Service Service must be performed by a qualified trained technician service agency or gas supplier If service is re...

Страница 16: ... frequency of cleaning can best be determined from experience at each location Maximum operating efficiency is dependent upon proper air circulation The accumulation of lint can restrict this airflow If the guidelines in this section are met an ADC dryer will provide many years of efficient trouble free and most importantly safe operation WARNING Lint from most fabrics is highly combustible The ac...

Страница 17: ... on the data label affixed to the right side panel area at the rear of the dryer When contacting ADC please have the model number and serial number available 1 Model Number This describes the style of dryer and type of heat gas electric or steam 2 Serial Number Allows the manufacturer to gather information on your particular dryer 3 Type of Heat This describes the type of heat for your particular ...

Страница 18: ...ADC Part No 112175 9 06 05 14 ...

Отзывы: