Installation
150-454-111-06
16
February 25, 2000
HRE-454
6
Using a megger-type Ohmmeter, measure the main cable shield resistance to manhole ground. The resistance
must be 5
Ω
or less.
7
If the Ohm requirement is not met, ground the main cable shield every 2,000 ft.
Figure 7.
Grounding for Flat Surface Mounted Unit.
S
LOT
C
HASSIS
G
ROUND
C
ONNECTIONS
Each of the four slots in the enclosure has both pins 1 and 27 connected to chassis ground. This allows them to
support 400/200 mechanics plugs which use either pins 1 or 27 for their chassis ground connection.
If the main feeder cable’s shield is bonded to the stub’s shield, the green insulated or bonded
stub shield wire, shown in
, should be disconnected from the metal card
cage base. This is recommended to reduce service affecting noise from being injected into the
doubler circuits from circulating ground loop currents, and to help inhibit corrosion.
No. 6 gauge wire
No. 6 gauge wire
Bullet bond
Field side
CO side
Splice case
Stub
HRE-454
Grounding
lug
Содержание 150-1122-03
Страница 4: ...Inspecting Shipment 150 454 111 06 iv February 25 2000 HRE 454 ...
Страница 45: ...150 454 111 06 Appendix B Technical Reference HRE 454 February 25 2000 37 Figure 18 HRU 512 Pin Assignments ...
Страница 46: ...Appendix B Technical Reference 150 454 111 06 38 February 25 2000 HRE 454 Figure 19 HRU 612 Pin Assignments ...
Страница 49: ...150 454 111 06 Appendix B Technical Reference HRE 454 February 25 2000 41 Figure 22 HRU 402 Pin Assignments ...
Страница 50: ...Appendix B Technical Reference 150 454 111 06 42 February 25 2000 HRE 454 Figure 23 H2TU R 402 Pin Assignments ...
Страница 51: ...150 454 111 06 Appendix B Technical Reference HRE 454 February 25 2000 43 Figure 24 HRE 454 Wiring Interfaces ...
Страница 74: ...Appendix D Glossary 150 454 111 06 66 February 25 2000 HRE 454 ...