HRE-206 List 1 Remote Enclosure
Part Number: 1146963
CLEI Code: T1MF50JG

HRE-206 List 2 Remote Enclosure
Part Number: 1146964
CLEI Code: T1MF60JG

Содержание 1146963

Страница 1: ...HiGain HiGain TECHNICAL PRACTICE HRE 206 List 1 Remote Enclosure Part Number 1146963 CLEI Code T1MF50JG HRE 206 List 2 Remote Enclosure Part Number 1146964 CLEI Code T1MF60JG...

Страница 2: ...ered trademarks of their respective companies Disclaimer of Liability Information contained in this document is company private to ADC DSL Systems Inc and shall not be modified used copied reproduced...

Страница 3: ...of damage If the equipment has been damaged in transit immediately report the extent of damage to the transportation company and to ADC DSL Systems Inc Order replacement equipment if necessary Check t...

Страница 4: ...Inspecting the Shipment LTPH TP 1003 02 Issue 2 iv June 1 2001 HRE 206 Lists 1 and 2...

Страница 5: ...__________________________________________________ 7 48 Volt Power Options 8 Slot Pin Assignments __________________________________________________________________ 9 HLU Alarm Output Interface 13 Fac...

Страница 6: ...m Hinged View 6 8 TB8 Pin Assignment 8 9 HRU Pin Assignments all lists 9 10 HLU 431 AND HLU 432 Pin Assignments 10 11 ERU 412 Pin Assignments 11 12 HDSL2 Remote Pin Assignments 12 13 System Alarm TB8...

Страница 7: ...HRU 402 or H2TU R 402 List 6 remote unit and a PSC 606 protection switching controller card The HRE 206 List 1 has RJ48C DS1 connectors and the HRE 206 List 2 has RJ48X connectors When the PSC 606 car...

Страница 8: ...e way of delivering DS1 High Capacity Digital Service HCDS to customers over metallic cable pairs The primary application of the HRE 206 remote enclosure is to house the remote units of a HiGain DS1 t...

Страница 9: ...rminal block connector for Slot 6 CPE and FAC interfaces TB7 Frame ground FGND 1 and FGND 27 a TB8 Terminal block connector for providing 48 Vdc battery return and supply for Slot 8 a Pin 27 of every...

Страница 10: ...ntroller card PSC 606 and the power supply module respectively Figure 4 HRE 206 Slot Connectors front view INSTALLATION This section provides information on installing and mounting the HRE 206 List 1...

Страница 11: ...the enclosure Do not block the airflow from the top or bottom of the unit Wall Mounting To mount the enclosure on a wall loosen the backplate and use it as a template for the four mounting holes as fo...

Страница 12: ...sure to the backplate To allow the enclosure to hinge either up or down remove the bottom or top retaining screws respectively 6 Rotate the main chassis back into position and replace the retaining sc...

Страница 13: ...e enclosure is shipped without a jumper across TB7 ADC recommends that the frame ground lug on the outside of the enclosure be connected to earth ground according to the grounding recommendations foun...

Страница 14: ...r mils per ampere HRU 402 3 5 watts 1 73 Westell 6048 01 100 ma 26 26 1 2 or 3 210 Teltrend 2005 250 ma 26 26 4 5 or 6 500 Troncom WPS 4806 520 ma 26 26 HDU 404 3 watts Unit is line powered No locally...

Страница 15: ...nd HLU 432 pin assignments Figure 11 on page 11 ERU 412 pin assignments Figure 12 on page 12 HDSL2 remote pin assignments Figure 9 HRU Pin Assignments all lists 27 25 23 21 19 17 15 13 11 9 7 3 5 1 DS...

Страница 16: ...ing HDSL L2Ring1 HDSL L2Tip1 Alarm Factoryburn in donotuse DS1Ring Circuit ground HDSL L1Ring XMT RCV HDSL L1Tip DS1Tip1 Chassisground 28 26 24 22 20 18 16 14 12 10 8 4 6 2 55 53 51 49 47 45 43 41 39...

Страница 17: ...nnectors that are not available in the HRE 206 27 25 23 21 19 17 15 13 11 9 7 3 5 1 Tip Tip1 Ring1 HDSL L2Tip1 HDSL L2Ring1 Ring HDSL L1Ring HDSL L1Tip Chassisground 28 26 24 22 20 18 16 14 12 10 8 4...

Страница 18: ...ng1 Circuit ground Ring IN OUT Tip DS1 Tip1 Chassisground Chassisground 28 26 24 22 20 18 16 14 12 10 8 4 6 2 55 53 51 49 47 45 43 41 39 37 35 32 31 56 54 52 50 48 46 44 42 40 38 36 34 30 33 29 Note A...

Страница 19: ...ITY SIDE HDSL CONNECTIONS The HDSL facility side ports are available through the FAC ports of the Euro style screw down terminal blocks Figure 14 shows the pin assignments for TB1 through TB4 slots 1...

Страница 20: ...If the Loop 1 and Loop 2 leads are reversed in 4 wire applications a CHREV Channels Reversed message appears in the ALARMS display field of the HiGain status screen This condition does not affect sys...

Страница 21: ...ments Figure 16 RJ48C Pin Assignments List 1 for Slot 1 through Slot 6 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 DS1_R_Ring 1 DS1_R_Ring 2 15 15 5 5 49 49 55 55 DS1_R_Tip 1 DS1_R_Tip 2 DS1_T_Ring 1 DS1_T_Ring 2...

Страница 22: ...Slot Pin Assignments LTPH TP 1003 02 Issue 2 16 June 1 2001 HRE 206 Lists 1 and 2 Figure 17 RJ48X Pin Assignments List 2 J9 J14 Metallic loopback connections when jack is empty 1 2 3 4 5 6 7 8...

Страница 23: ...tection switching controller card One type 400 power supply module Telco Facility Euro style terminal blocks or wire wrap pins CPE RJ48 Connector Options RJ48C List 1 RJ48X List 2 Power Supply Option...

Страница 24: ...return equipment to ADC 1 Locate the purchase order number under which the equipment was purchased You will need to provide this number to ADC Customer Service to obtain a return authorization 2 Call...

Страница 25: ...rsed COM Common CPE Customer Premises Equipment D DS1 Digital Signal level 1 E EMI Electromagnetic Interference ERU ETSI Remote Unit ETSI European Telecommunications Standards Institute H HCDS High Ca...

Страница 26: ...Appendix C Abbreviations LTPH TP 1003 02 Issue 2 20 June 1 2001 HRE 206 Lists 1 and 2...