L-852A-D, J & K ITCF, F-Range, ICAO LED Taxiway Centerline Light
96A0460 Rev. C
L-868 base can installation (load bearing)
© ADB Airfield Solutions All Rights Reserved
36
Figure 24:
Applying a coating to reduce friction during torquing
Connect the fixture plug into the isolation transformer receptacle.
Wrap 3 overlapping layers of electrical tape around the connection joint.
Install the fixture on the base can, while insuring that the cordset does not become pinched
between the fixture and the top of the base can.
Insure that the fixture is aimed in the proper direction.
Check if the fixture fits correctly on top of the base can.
Torque each bolt to
500
±10 in-lbs. (
56.5
± 1.1 N·m)
.
Use a manual calibrated torque wrench to tighten the bolt.
CAUTION
Do not use the bolts to force the fixture onto the base can. If this happens
the threaded hole in the base can be damaged.