Figure 17: Lens Gasket
Figure 18: Grease Application
7. Clean the lens recess in the cover thoroughly with any effective solvent.
8. Place the lens with the Lens Gasket back.
Make sure that you use a new Lens Gasket.
9. Place the Flat Gasket back.
Make sure you use a new Flat Gasket.
10. Close the light fixture.
Refer to
section.
6.4.9 Replacing the Top Cover Assembly
NOTICE
Top covers are delivered without the LED board assembly. LED board assemblies have to be ordered separately.
1. Open the light assembly: Refer to
Disassembling the Light Fixture
section.
2. Disconnect the top cover from the bottom cover.
3. Use a new top cover and go to
section.
RELIANCE Omni 1-Dome,
Maintenance
34
Copyright
©
ADB SAFEGATE, All Rights Reserved
Содержание RELIANCE Omni 1-Dome
Страница 1: ...RELIANCE Omni 1 Dome 8 inch User Manual UM 5073 Rev 1 0 2021 07 13 ...
Страница 2: ......
Страница 8: ...RELIANCE Omni 1 Dome List of Figures viii Copyright ADB SAFEGATE All Rights Reserved ...
Страница 10: ...RELIANCE Omni 1 Dome List of Tables x Copyright ADB SAFEGATE All Rights Reserved ...
Страница 20: ...RELIANCE Omni 1 Dome General Information 10 Copyright ADB SAFEGATE All Rights Reserved ...
Страница 26: ...RELIANCE Omni 1 Dome Installation 16 Copyright ADB SAFEGATE All Rights Reserved ...
Страница 28: ...RELIANCE Omni 1 Dome Operation 18 Copyright ADB SAFEGATE All Rights Reserved ...
Страница 52: ...RELIANCE Omni 1 Dome Maintenance 42 Copyright ADB SAFEGATE All Rights Reserved ...
Страница 54: ...RELIANCE Omni 1 Dome Troubleshooting 44 Copyright ADB SAFEGATE All Rights Reserved ...
Страница 60: ...RELIANCE Omni 1 Dome POWER TABLE 50 Copyright ADB SAFEGATE All Rights Reserved ...
Страница 62: ...RELIANCE Omni 1 Dome CABLE LOSS 52 Copyright ADB SAFEGATE All Rights Reserved ...
Страница 66: ......