4.9 Parameterization Work
4.9.1 Parameterizing the Constant Current Regulator
Make sure you have the following equipment before you start: a PC with the lucDMC tool installed, a Ethernet cable and a
programming adapter to connect the PC to the regulator.
There are two possibilities for parameterizing the CCR:
•
parameterization in the series circuit in a real system or
•
parameterization via connection to a testing system
Note
Make sure you comply with all currently applicable safety requirements and have got all the required permissions
to work with the airfield lighting system. Workers can be held responsible for non-compliance.
1. Connect the remote to the series circuit with the lamp, or with SRU102 or SRU112 with two lamps.
2. To start the configuration environment, press the toggle switch at the front of the regulator or press the key switch to
operate the regulator in the local mode.
Figure 47: Switch for local / remote mode — regulator front
3. Select level 0 for switching of the lights.
Figure 48: Step selection — regulator front
RELIANCE Intelligent Lighting
Operation
64
Copyright
©
ADB SAFEGATE, All Rights Reserved
Содержание RELIANCE Intelligent Lighting Platform III
Страница 1: ...RELIANCE Intelligent Lighting Platform III User Manual UM 5005 Rev 004 2020 08 06 ...
Страница 2: ......
Страница 10: ...RELIANCE Intelligent Lighting List of Figures x Copyright ADB SAFEGATE All Rights Reserved ...
Страница 12: ...RELIANCE Intelligent Lighting List of Tables xii Copyright ADB SAFEGATE All Rights Reserved ...
Страница 18: ...RELIANCE Intelligent Lighting Safety 6 Copyright ADB SAFEGATE All Rights Reserved ...
Страница 52: ...RELIANCE Intelligent Lighting Introduction 40 Copyright ADB SAFEGATE All Rights Reserved ...
Страница 56: ...RELIANCE Intelligent Lighting Installation 44 Copyright ADB SAFEGATE All Rights Reserved ...
Страница 118: ......