4.7.6 SRU Configuration Data
This section lists the values that can be set during configuration in the regulator for the RELIANCE IL using lucDMC.
Table 7: SRU configuration data
Data
type
Designation
Functionality
Value
range
Default
editable via
RFID reader?
editable via
SCROLL
command?
u32
u32ModuleSerialNumber
Serial number of SRU
32bit
0
yes
yes
u8
u8ModuleAddress
Remote address (128 is not
configured)
1-128
128
yes
yes
u8
u8GroupL1
Field for segment addresses for
lamp 1
1-63
1
yes
yes
u8
u8GroupL2
Field for segment addresses for
lamp 2
1-63
1
yes
yes
u8
u8MaxNoOfModules
Number of remotes in the circuit 1-127
127
yes
yes
u8
u8RUType2
Remote with 1 load = 0, RU with
2 loads = 1
0,1
0
yes
yes
u8
u8FeedbackMode
0 = SCRL-III compatible
1 = RM1 and 2 in different. half-
wave polarities
2 = RM1 and 2 in different. half-
wave polarities. plus remote
address (even/uneven number)
defines half wave
3 = RM1 and 2 in different. half-
wave polarities. plus remote
address (even/uneven number)
defines half wave
0, 1, 2, 3
0
yes
yes
u8
u8RGLMode
0= RGL mode OFF, 1 = RGL
mode ON
0,1
0
yes
yes
u8
u8BrokenLoadMode
0x00 = No retrigger (broken load
will only be startet again, if
circuit was without current)
0x01= Retrigger by timer
(u16CheckBrokenLoadCycleTime
_ms)
0x02 = Short-circuit monitoring
activated
0x04 = Monitoring of max.
voltage activated
Bit by bit
0x01
yes
yes
u16
u16CheckBrokenLoadCycleTime
_ms
Cycle time in ms for testing a
defective lamp in ON-state
900-30000 10000
yes
yes
u16
u16CheckLampOffState_ms
Cycle time in ms for testing a
defective lamp in OFF-state
(monitoring for thread break) in
ms
0-60000
0
yes
yes
u16
u16RGLBlinkFrequency_ms
Blinking frequency RGL in ms
250-60000 1000
yes
yes
u16
u16FailsafeTimeout_s
Failsafe Timeout in s
5 - 3600
90
yes
yes
u8
u8FailsafeValue_A
state lamp 1 after fail-safe mode:
0 = OFF, 1 = ON
0, 1
1
yes
yes
u8
u8FailsafeValue_B
State lamp 2 after fail-safe
mode: 0 = OFF, 1 = ON
0, 1
1
yes
yes
u8
u8InitialLampState_A
State Lamp 1 after powering the
SRU: 0 = OFF, 1 = ON
0, 1
0
yes
yes
RELIANCE Intelligent Lighting
Operation
58
Copyright
©
ADB SAFEGATE, All Rights Reserved
Содержание RELIANCE Intelligent Lighting Platform III
Страница 1: ...RELIANCE Intelligent Lighting Platform III User Manual UM 5005 Rev 004 2020 08 06 ...
Страница 2: ......
Страница 10: ...RELIANCE Intelligent Lighting List of Figures x Copyright ADB SAFEGATE All Rights Reserved ...
Страница 12: ...RELIANCE Intelligent Lighting List of Tables xii Copyright ADB SAFEGATE All Rights Reserved ...
Страница 18: ...RELIANCE Intelligent Lighting Safety 6 Copyright ADB SAFEGATE All Rights Reserved ...
Страница 52: ...RELIANCE Intelligent Lighting Introduction 40 Copyright ADB SAFEGATE All Rights Reserved ...
Страница 56: ...RELIANCE Intelligent Lighting Installation 44 Copyright ADB SAFEGATE All Rights Reserved ...
Страница 118: ......