3.0 Installation
The installation section covers the proper procedures for the installation of RELIANCE IL.
3.1 System Project Planning
The following requirements need to be fulfilled for overall system project planning:
•
Traffic routing requirements (segment assignment, routes, etc.)
•
Procedures to ensure system failures are avoided (redundancy, series circuit allocation, etc.)
•
Maximum of possible load variation within the circuit (harmonic distortion, Crest factor)
•
Maximum of allowed monitoring cycle time
•
Route taken for primary cabling to ensure that the current flow direction is the same for all lamp transformers
•
The transformer rating needs to be adequate to ensure transfer works
Note
Please contact ADB SAFEGATE project management team for further information.
3.2 Installing a SRU Remote
WARNING
Electric Shock
Read installation instructions in their entirety before starting installation.
• Become familiar with the general safety instructions in this section of the manual before installing,
operating, maintaining or repairing this equipment.
• Read and carefully follow the instructions throughout this manual for performing specific tasks and
working with specific equipment.
• Follow all applicable safety procedures required by your company, industry standards and
government or other regulatory agencies.
• Install all electrical connections to local code.
• Use only electrical wire of sufficient gauge and insulation to handle the rated current demand. All
wiring must meet local codes.
• Route electrical wiring along a protected path. Make sure they will not be damaged by moving
equipment.
Failure to follow these warnings may result in serious injury or equipment damage.
ADB SAFEGATE RELIANCE IL SRU are rectangular units with screw-on housings. Please see product data sheet for dimensions
and weight.
Remotes of type 101 or 111 are equipped with two cables. The first cable is used for connecting the remote to the series
circuit transformer with a FAA style 1 compliant (2-pin) plug. The second cable, having a FAA style 3 compliant connector, is
used to connect the remote to the light or sensor to be monitored.
UM-5005, Rev. 004, 2020/08/06
41
Copyright
©
ADB SAFEGATE, All Rights Reserved
Содержание RELIANCE Intelligent Lighting Platform III
Страница 1: ...RELIANCE Intelligent Lighting Platform III User Manual UM 5005 Rev 004 2020 08 06 ...
Страница 2: ......
Страница 10: ...RELIANCE Intelligent Lighting List of Figures x Copyright ADB SAFEGATE All Rights Reserved ...
Страница 12: ...RELIANCE Intelligent Lighting List of Tables xii Copyright ADB SAFEGATE All Rights Reserved ...
Страница 18: ...RELIANCE Intelligent Lighting Safety 6 Copyright ADB SAFEGATE All Rights Reserved ...
Страница 52: ...RELIANCE Intelligent Lighting Introduction 40 Copyright ADB SAFEGATE All Rights Reserved ...
Страница 56: ...RELIANCE Intelligent Lighting Installation 44 Copyright ADB SAFEGATE All Rights Reserved ...
Страница 118: ......