Setting sequence
1. Go to system settings by selecting Set/Set/More/Sys.
1. Browse the desired parameter with Next, adjust it with + / - and select Set to confirm.
1. If the CCR is with direction changer, select the other direction and set required parameters.
4.6.9 Remote control settings
These general remote control settings are only enabled when the control switch is in Off-position.
Note
: ERR indication is provided if settings are not accepted.
The CCR automatically detects if serial or parallel or no remote control card is connected and provides setting menus
accordingly:
•
Rcmode: Display only, serial (computerized) or parallel control card or no card detected.
•
Bustype: Serial mode only. Displays which type of fieldbus card is detected (e.g. Profibus)
•
Fieldb: Serial mode only, tells if 1 or 2 (redundant system) serial cards are detected
•
Fails: Serial mode only. Failsafe mode i.e. what happens in case of bus failure:
Setting Function
Cont
Continues with selected control status
Fs
Selects the failsafe step 0-7 (failsafe)
Fs off
Selects the failsafe step only if control status is Off, else continues with selected control stat.
ContHB Continues with selected control status, Heart beat signal is used for bus failure detection.
Fs HB
Selects the failsafe step 0-7 (failsafe), Heart beat signal is used for bus failure detection.
Fs of HB Selects the failsafe step only if control status is Off, else continues with selected control stat. Heart beat signal is used for bus
failure detection.
In case of direction changer CCR dir 1 is considered as failsafe direction and all circuits with circuit selector CCRs.
•
F step: Serial mode only. Select a failsafe step if Fs or Fs off modes are selected
•
Dec/bin: parallel mode only: coding of control signals.
•
Cont/imp: parallel mode only: mode of control signals
•
ComF-m: defines if all fault signals are summed to Com-fault indication (SumF) or it contains only U1, f1 and T alarms
(SysF).
Displays with serial remote control card detected:
Header / function
Data 1
Data 2
Fact set
Allowed range
Remote control set
Serial/ none
Rcmode
* Project
Autodetect
Bustype
Bustype
* Project
Autodetect
No of serial cards
Fieldb
* Project
Autodetect
Failsafe mode
Fails
Cont
Cont / Fs / Fs off / ContHB / FS HB / FsofHB
Failsafe step
F step
00
0-7
IDM 8000
User Interface
46
Copyright
©
ADB Safegate, All Rights Reserved
Содержание IDM 8000
Страница 1: ...IDM 8000 CCR User Manual UM_IDM 8000 Rev 1 7 2021 05 06 ...
Страница 2: ......
Страница 8: ...IDM 8000 TABLE OF CONTENTS viii Copyright ADB Safegate All Rights Reserved ...
Страница 10: ...IDM 8000 List of Figures x Copyright ADB Safegate All Rights Reserved ...
Страница 12: ...IDM 8000 List of Tables xii Copyright ADB Safegate All Rights Reserved ...
Страница 18: ...IDM 8000 Safety 6 Copyright ADB Safegate All Rights Reserved ...
Страница 20: ...IDM 8000 About this Manual 8 Copyright ADB Safegate All Rights Reserved ...
Страница 76: ...IDM 8000 Troubleshooting 64 Copyright ADB Safegate All Rights Reserved ...
Страница 92: ...IDM 8000 Appendix F Parallel remote control example 80 Copyright ADB Safegate All Rights Reserved ...
Страница 100: ...IDM 8000 Appendix I Commissioning test report form 88 Copyright ADB Safegate All Rights Reserved ...
Страница 104: ...IDM 8000 Appendix J Spare part list 92 Copyright ADB Safegate All Rights Reserved ...
Страница 106: ...IDM 8000 Appendix K Components of electronics 94 Copyright ADB Safegate All Rights Reserved ...
Страница 107: ...Appendix L Appendix L CCR components UM_IDM 8000 Rev 1 7 2021 05 06 95 Copyright ADB Safegate All Rights Reserved ...
Страница 113: ...UM_IDM 8000 Rev 1 7 2021 05 06 101 Copyright ADB Safegate All Rights Reserved ...
Страница 114: ...IDM 8000 Appendix M Output Terminals 102 Copyright ADB Safegate All Rights Reserved ...
Страница 118: ......