5.2.5 LMC PCB
Save IO profile
Note
Only save the IO profile if you configured the flashing system with the configuration software tool.
1. Switch ON the equipment.
2. Open the configuration software tool.
3. Go to menu SAVE .
4. Select Save . The used IO profile is now saved on your PC.
5. Switch OFF all power to the equipment. See §
Prepare: Switch OFF power supply
.
Replace
6. Disconnect the cables to the LMC PCB.
7. Remove the eight nuts (A).
8. Replace the LMC PCB (B).
9. Set the dip-switches and straps to the same settings as the old LMC PCB .
10. Install the eight nuts (A)
Connect cables
11. Connect the cables to the connectors:
•
Power distribution from the DC unit to TB1;
•
MOV connection to P6;
•
Door switch to P7;
•
External temperature probe to P8;
•
Multiwire connection to P5 (optional);
UM-4019_AM02-620e, Rev. 3.0, 2020/05/12
39
Copyright
©
ADB Safegate, All Rights Reserved
Содержание FCU-1-in-1
Страница 2: ......
Страница 8: ...Flashing System Maintenance TABLE OF CONTENTS viii Copyright ADB Safegate All Rights Reserved ...
Страница 18: ...Flashing System Maintenance Safety 8 Copyright ADB Safegate All Rights Reserved ...
Страница 23: ...3 2 2 FCU 3 UM 4019_AM02 620e Rev 3 0 2020 05 12 13 Copyright ADB Safegate All Rights Reserved ...
Страница 28: ...Flashing System Maintenance Introduction 18 Copyright ADB Safegate All Rights Reserved ...
Страница 42: ...Flashing System Maintenance Commissioning 32 Copyright ADB Safegate All Rights Reserved ...
Страница 64: ...Flashing System Maintenance Maintenance 54 Copyright ADB Safegate All Rights Reserved ...
Страница 74: ...Flashing System Maintenance Checks and measurements 64 Copyright ADB Safegate All Rights Reserved ...
Страница 102: ...FCU 3 Flashing System Maintenance PCB drawings and settings 92 Copyright ADB Safegate All Rights Reserved ...
Страница 106: ...Flashing System Maintenance Technical data 96 Copyright ADB Safegate All Rights Reserved ...
Страница 110: ......