6-14
DuraStor 412R/6320SS/7320SS Installation and User’s Guide
SPARE UNUSABLE
The disk drive still
contains metadata
that must be cleared.
Clear the metadata
from the spare drive.
Refer to the
Storage
Manager Pro User’s
Guide
.
SMART EVENT
A disk drive
informational
exceptions page
control (IEPC)
predictive failure
message was
received. No actions
by the controller are
taken on the drive for
these events.
Run diagnostics
available from your
operating system on
the affected disk
drive. Replace the
drive, if necessary.
See
ARRAY OFFLINE
More than one disk
drive in a RAID 0 or
volume set went
down, bringing the
array to an offline
state. This array is no
longer accessible by
the host.
Replace the bad drive
(see
and restore the data
from backup.
VOLT/TEMP WARN
The analog-to-digital
converter monitored
a temperature and/or
voltage in the
warning range.
■
Check that the
controller’s fan is
running.
■
Check that the
ambient
temperature is not
too warm. See
.
UNWRITABLE
CACHE
The SDRAM cache
has battery backed-
up data, and the
arrays assigned to
this data are not
present.
■
Determine which
disk drives are
missing and
reinstall them, or
■
Select Yes when
asked if you want
to discard this data.
SDRAM CORR ECC
A correctable single-
bit SDRAM ECC
error occurred.
If this error occurs
frequently, replace
the memory.
Event
Definition
Recommended Action